  • Hello! I am an AI chatbot trained to assist you with the Duracell CopperTop MN 1500 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
**
6/08
1.0 mm
MIN.
( + )
14.5
13.5
5.5 mm
Max.
( )
50.5
49.5
Dimensions shown are ANSI standards
mm
mm
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
020406080100120
Service Hours
Voltage
3.9 OHMS
10 OHMS
24 OHMS
43 OHMS
MN1500
Size: AA (LR6)
Zn/MnO2
Alkaline-Manganese Dioxide Battery
Nominal Voltage: 1.5 V
Impedance:
Typical Weight: 24 gm (0.8 oz.)
Typical Volume: 8.4 cm
3
(0.5 in.
3
)
Terminals: Flat
Operating Temperature
Range:
-20
o
C to 54
o
C
(-4
o
F to 130
o
F)
ANSI:
IEC:
15A
LR6
Operating Voltage
Storage Temperature
Range:
1.6 - 0.75V
-20
o
C to 35
o
C
120 m-ohm @ 1kHz
Berkshire Corporate Park
Berkshire Corporate Park
Berkshire Corporate Park
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Telephone: Toll-free 1-800-544-5454
Internet: www.
Internet: www.
duracell
duracell
.com
.com
MN1500_US_CT.PDF
Page 1 of 2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
**
6/08
TYPICAL DISCHARGE CHARACTERISTICS
AT 21°C (70°F)
Amp Hours
Voltage
TYPICAL DISCHARGE CHARACTERISTICS
AT 21°C (70°F)
TYPICAL CONSTANT CURRENT DISCHARGE
CHARACTERISTICS AT 21°C (70°F)
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
0246810
Service Hours
Voltage
1.00 Amp
0.75 Amp
0.50 Amp
0.25 Amp
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
0 0.5 1 1.5 2 2.5
1.00 Watt
0.75 Watt
0.50 Watt
0.25 Watt
MN1500
Size: AA (LR6)
Zn/MnO2
Alkaline-Manganese Dioxide Battery
0
0.5
1
1.5
2
2.5
3
50 100 250 500
Discharge Current (mA)
Amp Hours
4 H/D
1 H/D 1 H/D
30 M/D
TYPICAL DISCHARGE PERFORMANCE
AT 21°C (70°F)
TYPICAL DC RESISTANCE CHARACTERISTICS
AT 21°C (70°F)
MN1500_US_CT.PDF
Page 2 of 2
1
10
100
1000
1 10 100 1000
Discharge Current (mA)
Service Hours
1.1 V
1.0 V
0.9 V
0.8 V
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Depth of Discharge
Closed Circuit Voltage
0
0.2
0.6
0.8
1
1.2
1.4
1.6
1.8
DC Resistance
Low drain: 0.1A/1 hour - 0.5A/1 sec
High drain: 1A/5 min - 2A/1 sec
High drain
Low drain
High drain
Low drain
Berkshire Corporate Park
Berkshire Corporate Park
Berkshire Corporate Park
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Telephone: Toll-free 1-800-544-5454
Internet: www.
Internet: www.
duracell
duracell
.com
.com
/