062015_R.A1+700A.5.0
A
B
C
S
S
Press to select the group
To turn off the group by pressing when the group is blinking
Rotate the dial to adjust the
EV compensation (TTL)/ Power output (Manual)/ Zoom position (Zoom)
Mode
TTL Manual Zoom
Nomenclature
LED panel
Battery compartment door
Flash mode button
Unlock button
Pilot button (Test flash button)
On/ Off switch (Sound On/ Off button)
1
2
3
4
5
6
Select/ Set button
Strap hole
Select dial
AF-assis light
Mounting foot
Hotshoe contacts
7
8
9
10
11
12
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
Group A
Group B
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
Group C
Quick Manual for Canon/ Nikon/ Sony
Commander
+
“Beep” On/ Off
Setting
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/128 1/64 1/32 1/16 1/8 1 /4 1 /2 1 /1
Set
Hold 3 sec
Hold 3 sec
“Beep”
“Beep”
Blink
“Beep”
STOP
5 sec
OK
Di700A
Di700A
Di700A
Di700A
Air 1
Commander
Air 1
Commander
Air 1
Commander
Air 1
Commander
Hold 3 sec
Press
Press 1 time to confirm
Rotate the dial to
select 1 in 8 Channels
S
S
Group A/B/C setting
in Di700A
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
Orange
White
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/16 1/8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/16 1/8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/16 1/8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/16 1/8 1/4 1/2 1/1
A B C BA C
A
B
C
Z
24 35 50 70 85 105 135 200
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
2 1.5 1 0.5 0.5 1 1.5 2
+ + + +
A
B
C
Z
24 35 50 70 85 105 135 200
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
2 1.5 1 0.5 0.5 1 1.5 2
+ + + +
A
B
C
Z
24 35 50 70 85 105 135 200
1/128 1/64 1/32 1/16 1/8 1/4 1/2 1/1
2 1.5 1 0.5 0.5 1 1.5 2
+ + + +
Step 2: Binding setting
Step 3: Channel setting
Step 4: Desire group setting
Step 1: All the units are OFF
Compatible with
Nissin Air System
Ready!
NAS
Binding before use.
!
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
Set
-2.0
-1.5
-1.0
-0.5
+0.5
+1.0
+2.0
+1.5
1/1281/64 1/32 1/161 /8 1/4 1/2 1/1
(Completed)
(*2~4s signal delay on Commander
*Do not operate until the binding
process is finished)
/ / /
The binding setting is memorized and remains
unchanged when power on/ off.
The Air 1 and Di700A display screen automatically turns
off in about 2 mintues after the setting job is terminated.
For a test-flash, press the pilot button.
Press the Mode button for 5 seconds, all the setting will
be resetted to the factory default.
To turn off the Commander unit manually, press the
on/ off switch and hold it for 1 second.
Commander unit
High-speed synchronization is controlled by Air 1.
To enable/ disable on Air 1:
Press and hold Pilot button in 3 seconds
Pilot button starts blinking twice.
For Sony Only
For Sony - Before using Commander Air 1, please install Air 1 on camera and change the Flash mode to “WL” in camera menu.
For using with Canon camera model EOS 1DX and 7DM2.
Before Binding setting, please follow the technical setting on Commander Air 1 user’s manual/ Appendix 1.