Acer ARMC_2 User manual

Type
User manual
Acer ARMC/2
User’s Guide
MAN-840
07/09/04
© Copyright 1998-2004 American Megatrends, Inc.
All rights reserved.
American Megatrends, Inc.
6145-F Northbelt Parkway
Norcross, GA 30071
This publication contains proprietary information which is protected by copyright. No
part of this publication can be reproduced, transcribed, stored in a retrieval system,
translated into any language or computer language, or transmitted in any form
whatsoever without the prior written consent of the publisher, American Megatrends, Inc.
American Megatrends, Inc. acknowledges the following trademarks:
Intel is a registered trademark of the Intel Corporation.
MS-DOS and Microsoft are registered trademarks of the Microsoft Corporation.
Microsoft Windows is a trademark of the Microsoft Corporation.
IBM, AT, VGA, PS/2, and OS/2 are registered trademarks and XT and CGA are
trademarks of the International Business Machines Corporation.
Other trademarks and trade names may be used in this document to refer to either the
entities claiming the marks and names or their products. American Megatrends, Inc.
disclaims any proprietary interest in trademarks and trade names other than its own.
Revision History
02/25/04 Preliminary release
03/15/04 Updated GUI
04/02/04 Updated ARMC2RMseek Utility instructions
05/04/04 Password/User Name length changed to max 32 characters
05/14/04 Added Full Screen Toolbar & ARMC2ConfigApp FW Flash Module
06/04/04 Removed Battery Backup Unit Information
07/09/04 Removed Optional Modem Information
ARMC/2 User’s Guide
ii
Table of Contents
Revision History............................................................................................................................ii
Table of Contents.........................................................................................................................iii
Disclaimer ....................................................................................................................................vi
Optional Components.................................................................................................................vii
FCC Class B Statement..............................................................................................................vii
Chapter 1 Introduction.......................................................................................................... 1
Features....................................................................................................................................... 1
Important NOTES: ......................................................................................................................... 3
Chapter 2 Installing Your ARMC/2 Card ............................................................................. 4
Before You Start .......................................................................................................................... 4
Avoid Electro-Static Discharge (ESD)...................................................................................... 4
ARMC/2 Installation and Setup.................................................................................................... 4
Step 1 Unpack the ARMC/2 Card (and check jumper settings) .................................................. 5
ARMC/2 Card Layout............................................................................................................... 5
ARMC/2 MAC Address............................................................................................................. 5
JP4 and JP5 Chassis/Motherboard Power Switch................................................................... 6
JP6 ARMC/2 Reset Button....................................................................................................... 6
JP7 and JP8 Chassis/Motherboard Reset Switch.................................................................... 6
JP11 Flash Write Enable/Disable............................................................................................. 6
JP12 Diagnostic and Recovery Mode Jumper......................................................................... 7
JP13 and JP14 PCI Bus SMB Data and Clock Jumper........................................................... 7
Step 2 Plug in the ARMC/2 Card into the Host System and Attach Internal Cables................... 7
J3 Service Connector............................................................................................................... 7
J4 JTAG (Joint Test Action Group) ICE (In-Circuit Emulator) Connector................................ 7
J5 IPMB (Intelligent Platform Management Bus)..................................................................... 8
IPMB (Intelligent Platform Management Bus).......................................................................... 8
J9 ARMC/2 Feature Connector................................................................................................ 9
JP2 Serial Port Connector........................................................................................................ 9
JP3 Service Connector............................................................................................................. 9
JP4 and JP5 Chassis/Motherboard Power Switch................................................................. 10
JP6 ARMC/2 Reset Button..................................................................................................... 10
JP7 and JP8 Chassis/Motherboard Reset Switch.................................................................. 10
Step 3 Connect External Cables................................................................................................ 10
Step 4 Confirm the Motherboard’s BIOS Settings..................................................................... 11
Step 5 Install the Operating System and ARMC/2 Drivers........................................................ 11
Installing Virtual Floppy Drivers on Microsoft® Windows Operating Systems....................... 12
Step 6 Install the Acer ARMC/2 Windows Software Components............................................. 15
Step 7 Setup Your Client Internet Browser................................................................................ 19
Step 8 Connect to the ARMC/2 from a Client System............................................................... 23
Step 9 Load the ARMC/2 SDR and Soft Processor (SP) File for Your Server Board Model.... 27
Chapter 3 Locating Your ARMC/2 Card ............................................................................ 31
Overview.................................................................................................................................... 31
Locating Your ARMC/2 Card ..................................................................................................... 31
IP Address Range...................................................................................................................... 35
Usage......................................................................................................................................... 37
Chapter 4 Using Your ARMC/2........................................................................................... 39
ARMC/2 GUI Overview.............................................................................................................. 39
Default User Name and Password ............................................................................................ 39
ARMC/2 GUI Explained............................................................................................................. 40
Menu Bar................................................................................................................................ 40
Preface
iii
Quick Launch Icons................................................................................................................ 41
Session Information................................................................................................................ 41
Manage Group........................................................................................................................... 42
Remote Console........................................................................................................................ 43
Redirection................................................................................................................................. 44
Setting up Internet Explorer....................................................................................................44
Staring Redirection................................................................................................................. 48
Remote Console Shortcut Key Combinations........................................................................ 50
Console Redirection Window................................................................................................. 51
Console Redirection Toolbar.................................................................................................. 54
Console Redirection Toolbar Status ...................................................................................... 54
Console Redirection Toolbar Toggle Buttons ........................................................................ 55
Start CD-ROM Drive Redirection ........................................................................................... 56
Stop CD-ROM Drive Redirection............................................................................................ 59
Start Floppy Drive Redirection ............................................................................................... 61
Stop Floppy Drive Redirection................................................................................................ 64
ARMC2 Floppy Image Creator............................................................................................... 66
Creating a Floppy Image........................................................................................................ 66
Transferring a Floppy Image to a Floppy Disk....................................................................... 69
Remote Power Control............................................................................................................... 74
Upgrade Firmware..................................................................................................................... 75
Updating Your ARMC/2’s Firmware....................................................................................... 76
Reset ARMC/2........................................................................................................................... 81
Configure Group ........................................................................................................................ 83
Users.......................................................................................................................................... 84
Adding Users.......................................................................................................................... 85
Removing Users..................................................................................................................... 86
Viewing and Editing Users ..................................................................................................... 87
Network...................................................................................................................................... 88
Firewall....................................................................................................................................... 90
Alert Notification......................................................................................................................... 92
Date & Time............................................................................................................................... 93
Serial Port .................................................................................................................................. 94
SSL Certificate........................................................................................................................... 95
PMCP File Upload ..................................................................................................................... 97
IPMI Configuration................................................................................................................... 102
Server OS Monitoring & Recovery........................................................................................... 103
View Group .............................................................................................................................. 104
ARMC/2 Card Health............................................................................................................... 105
Event Log................................................................................................................................. 106
Server Health........................................................................................................................... 107
General Information................................................................................................................. 108
General Information : Version .............................................................................................. 108
General Information : Features ............................................................................................ 109
General Information : Detailed Versions.............................................................................. 109
Last Saved Crash Screen........................................................................................................ 110
Appendix A ARMC/2 Universal Cable................................................................................. 111
ARMC/2 Universal Cable Layout............................................................................................. 111
Appendix B ARMC2ConfigApp ........................................................................................... 113
Overview.................................................................................................................................. 113
ARMC2ConfigApp.................................................................................................................... 113
User Manager Tab ............................................................................................................... 115
Adding a User....................................................................................................................... 116
User Properties .................................................................................................................... 117
ARMC/2 User’s Guide
iv
Network Configuration Tab................................................................................................... 118
Advanced Tab ...................................................................................................................... 119
WinCuri .................................................................................................................................... 120
WinCuri.exe Help File........................................................................................................... 120
LinCuri...................................................................................................................................... 122
LinCuri Help File................................................................................................................... 123
Appendix C ARMC/2 Remote Recovery Application (RRA) ............................................. 125
ARMC/2 Card Remote Recovery Application (RRA)............................................................... 125
Appendix D Troubleshooting.............................................................................................. 132
Screen Distortion ..................................................................................................................... 132
Problem................................................................................................................................ 132
Symptom .............................................................................................................................. 132
Solution................................................................................................................................. 133
BMC Not Responding.............................................................................................................. 134
Problem................................................................................................................................ 134
Symptom .............................................................................................................................. 134
Solution................................................................................................................................. 134
Cannot Power On the Host System Remotely......................................................................... 135
Problem................................................................................................................................ 135
Symptom .............................................................................................................................. 135
Solution................................................................................................................................. 135
Complete Flash........................................................................................................................ 135
Problem................................................................................................................................ 135
Symptom .............................................................................................................................. 135
Solution................................................................................................................................. 135
Appendix E Serial Over LAN............................................................................................... 137
Hardware Setup....................................................................................................................... 137
BIOS..................................................................................................................................... 138
Appendix F Port Usage........................................................................................................ 139
Port Usage Table..................................................................................................................... 139
Appendix G MAC Address Map........................................................................................... 141
Appendix H Tree Structure and Description of CD Contents .......................................... 142
ARMC/2 CD ............................................................................................................................. 142
ARMC/2 CD Image............................................................................................................... 142
CD Contents......................................................................................................................... 142
Appendix I GtkRConsoleARMC2 for Linux ...................................................................... 144
Installation................................................................................................................................ 144
Notes........................................................................................................................................ 145
Limited Warranty
The buyer agrees that if this product proves to be defective, American Megatrends is only
obligated to repair or replace this product at American Megatrends’ discretion according
to the terms and conditions of the warranty registration card that accompanies this
product. American Megatrends shall not be liable in tort or contract for any loss or
damage, direct, incidental or consequential resulting from the use of this product. Please
see the Warranty Registration Card shipped with this product for full warranty details.
Preface
v
Technical Support
Please contact your local Acer Authorized Reseller for technical support.
Disclaimer
This manual describes the operation of the Acer ARMC/2 card. Although efforts have
been made to assure the accuracy of the information contained here, Acer expressly
disclaims liability for any error in this information, and for damages, whether direct,
indirect, special, exemplary, consequential or otherwise, that may result from such error,
including but not limited to the loss of profits resulting from the use or misuse of the
manual or information contained therein (even if Acer has been advised of the possibility
of such damages). Any questions or comments regarding this document or its contents
should be addressed to Acer at the address shown on the inside of the front cover.
Acer provides this publication “as is” without warranty of any kind, either expressed or
implied, including, but not limited to, the implied warranties of merchantability or fitness
for a specific purpose.
Some states do not allow disclaimer of express or implied warranties or the limitation or
exclusion of liability for indirect, special, exemplary, incidental or consequential
damages in certain transactions; therefore, this statement may not apply to you. Also, you
may have other rights which vary from jurisdiction to jurisdiction.
This publication could include technical inaccuracies or typographical errors. Changes
are periodically made to the information herein; these changes will be incorporated in
new editions of the publication. Acer may make improvements and/or revisions in the
product(s) and/or the program(s) described in this publication at any time.
Requests for technical information about Acer products should be made to your Acer
authorized reseller or marketing representative.
Retail Packing List
You should have received the following:
a ARMC/2 card
one USB cable
one universal cable
a warranty card
this ARMC/2 User's Guide (located on the ARMC/2 CD)
a ARMC/2 Quick Installation Guide
a ARMC/2 CD
a ARMC/2 external power adapter
Note: Your ARMC/2 may or may not ship with everything listed in the Retail Packing List.
Contact your Acer authorized reseller to find out what is shipped with your ARMC/2.
ARMC/2 User’s Guide
vi
Optional Components
The following component does not come with your ARMC/2 card. You must order this
component separately.
Power cable
FCC Class B Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Warning
Changes or modifications to this device not expressly approved by American
Megatrends could void the user’s authority to operate the equipment.
Preface
vii
Chapter 1 Introduction
Features
Feature Description
Key Feature
100% out-of-band
100% operating system independent
Soft Processor
provides out-of-band connectivity
plugs into a mission critical server
half-sized PCI form factor plugs into any PCI slot
Remote Client
industry standard Internet browser (any JavaScript 1.2 capable)
manage the server from anywhere in the world
SSL v3 for secure connection
Processor System On
Chip (SOC)
32-Bit 266 MHz ~ 400 MIPS MMU
16 K I-cache
16 K D-cache
Memory
32 megabyte PC-133 MHz SDRAM standard (soldered on PCB, you cannot
upgrade or remove)
Flash
16 bit, 16 megabyte flash ROM (soldered on PCB, you cannot upgrade or
remove)
Ethernet LAN
integrated SOC 10/100 MAC
external level one 10/100 BASE-TX Ethernet
I2C Controller Hardware
Monitor (OEM version
feature)
ambient temperature monitoring
PCI voltages monitoring
card internal voltages monitoring
RTC
external RTC for time stamp of events
Power Supply
switching logic between optional 6 V wall adapter, 5 V PCI, and 3.3 V PCI
Form Factor
half-size standard PCI card
Environmental
Specifications
storage temperature: -20 degrees to 80 degrees C
relative humidity: 5 to 80 percent non-condensing @ 40 degrees
operating temperature: 0 to 45 degrees C
vibration: 2.5G acceleration over 2000 Hz sine wave, 2oct/mian sine sweep
shock: 20G; 11 msec duration, half-sine shock sweep
Monitoring
IPMI 1.5 compliant (OEM version feature)
I2C sensors (OEM version feature)
SDR and Soft Processor (SP) file support for easy customization (OEM
version feature)
OEM specific
Cont’d
Chapter One : Introduction
1
Features, Continued
Feature Description
Communication
10/100 megabit Ethernet LAN
TCP/IP
DHCP enabled
SNMP
web-based interface
USB Device Controller
for Mouse/Keyboard
USB 1.1 device controller
USB Device Controller
for CD-ROM
USB 2.0 device controller
USB Device Controller
for FDD
USB 1.1 device controller
USB Hub
USB 2.0 hub
Serial Port X 3
debug port
RS485
one external
Debug Support
Jtag ICE
Alert Notification
SNMP trap up to eight destinations
email notification
Console Redirection
via 10/100 megabit Ethernet LAN
up to three multiple redirection sessions
up to 15 screens per second high speed redirection hardware engine
no overhead on the host system, complete operating system independence
redirect BIOS screens and setup screens
seamless text and graphics transition
Security
SSL (Secured Socket Layer) 3.0 (Pass-phrase encrypted certificates are not
supported)
DAA (Digestive Authentication Access)
MD-5
Virtual Boot
USB 2.0 CD-ROM
USB floppy
supports boot to image
allows remote operating system boot up and installation
Note: For information on how to create a bootable CD, visit nero.com or
roxio.com. You can do a search on how to create a bootable CD using their
products. You can also consult your CD writer's documentation.
Host Side Operating
System Support
Windows 2000/2003 and above
RedHat Linux 9.0; Enterprise Linux 3.0, AS; Enterprise Linux 3.0 Update2,
AS
Platform Management
Configuration Program
(PMCP)
Available
ARMC/2 User’s Guide
2
Important NOTES:
There are some NOTES for ARMC/2.
NOTE1.
This note applies to the Altos G520/G710/R710/R510 with Redhat Enterprise Linux 3.0
and Altos G520/R510 with Redhat 9.0. Because these server can not detect the virtual
device (keyboard/mouse/CDROM/Floppy) in Redhat Enterpeise Linux 3.0 and Redhat
Linux 9.0. These some methods can solve this issue.
Method 1.
. Disable the USB 2.0 controller in BIOS (only for G520, R510 and R710)
Method 2.
. Connect a external USB 1.1 hub to server, then connect the ARMC/2 USB
cable behind the USB 1.1 hub.
Method 3.
. Users can unplug and plug ARMC/2 USB cable then server can recognizes
virtual device in Linux. But if you shutdown or restart the server, you must unplug and plug
ARMC/2 USB cable again.
NOTE2.
For “Full Screen function key (Alt + F) issue if client computer OS is Linux:”
IF client computer OS is RH9.0 or RH Enterprise 3.0 Update 1, the function key
is no problem. But it is other Linux version; please use toolbar to control the
Full Screen mode.
NOTE3.
For “Use Mazilla browser of Linux OS on client computer to login ARMC/2 website”
IF client computer OS is Linux, please use the Mazilla browser version to 1.6 or later to login
ARMC/2 website.
NOTE4.
For “Must connect external power with ARMC/2.”
IF ARMC/2 does not connect external power, it will bring about the system
cannot power on by pressing power button.
NOTE5.
“The host heartbeat function is ONLY supported under Windows OS.”
Chapter Two : Installing Your ARMC/2 Card
3
Chapter 2 Installing Your ARMC/2 Card
Before You Start
Avoid Electro-Static Discharge (ESD)
Electro-Static Discharge (ESD) can damage the ARMC/2 card and other system
components. Keep your ARMC/2 card in its anti-static bag until it is to be installed.
Avoid contact with any component or connector on any adapter card, printed circuit
board, or memory module. Handle these components by the mounting bracket.
Perform all unpacking and installation procedures on a ground-connected anti-static mat.
Wear an anti-static wristband grounded at the same point as the anti-static mat. You can
also use a sheet of conductive aluminum foil grounded through a one megaohm resistor
instead of the anti-static mat. Similarly, a strip of conductive aluminum foil wrapped
around the wrist and grounded through a one megaohm resistor serves the same purpose
as a wristband.
ARMC/2 Installation and Setup
Use the following steps to install the ARMC/2 card into the host system.
Step Action
1 Unpack the ARMC/2 card (and check jumper settings)
2 Plug in the ARMC/2 card into the host system and attach internal cables
3 Connect external cables
4 Confirm the motherboard’s BIOS settings
5 Install the operating system and ARMC/2 card’s drivers
6 Install all ARMC/2 Windows Software Components
7 Setup your client system’s Internet browser
8 Connect to the ARMC/2 from a client system
9 Load the ARMC/2 SDR and Soft Processor (SP) File for your motherboard or
server board model
Note: Inspect the cardboard carton for obvious damage.
ARMC/2 User’s Guide
4
Step 1 Unpack the ARMC/2 Card (and check jumper settings)
ARMC/2 Card Layout
ARMC/2 MAC Address
Your ARMC/2 card has a unique MAC address. The MAC address is the only way to
distinguish one ARMC/2 card from another when you run programs such as Remote
Recovery Application (RRA) and ARMC2RMseek Locator. You can write down your
ARMC/2 card’s MAC address in the table below or in Appendix H, MAC Address Map.
See the first line for an example.
MAC Address Location Description
00-40-D9-02-9B-3C Server Room, Rack 2, 5
Windows 2003 Advanced
Server, Mail Server
Cont’d
Chapter Two : Installing Your ARMC/2 Card
5
Step 1 Unpack the ARMC/2 Card (and check jumper settings), Continued
Check the following jumpers:
Jumper Setting
JP4 Confirm that pins one and two are open.
JP5 Confirm that pins one and two are open.
JP6 Confirm that pins one and two are open.
JP7 Confirm that pins one and two are open.
JP8 Confirm that pins one and two are open.
JP11 Confirm that pins one and two are shorted.
JP12 Confirm that pins one, two and three are open.
JP13 If your hosts system’s motherboard has support for I2C on the PCI slots,
place a short pins one and two. If not, confirm that pins one and two are
open.
JP14 If your hosts system’s motherboard has support for I2C on the PCI slots,
place a short pins one and two. If not, confirm that pins one and two are
open.
Note: The ARMC/2 cards have these two jumpers, JP13 and JP14.
JP4 and JP5 Chassis/Motherboard Power Switch
Verify that there is no jumper on JP4 and JP5. These two headers are to be used with a
cable, not a jumper.
JP6 ARMC/2 Reset Button
You can temporarily short this jumper to reset your ARMC/2 card. For normal operations,
verify that there is no jumper on JP6.
Pin Description
1 Ground
2 Reset #
JP7 and JP8 Chassis/Motherboard Reset Switch
Verify that there is no jumper on JP7 and JP8. These two headers are to be used with a
cable, not a jumper.
JP11 Flash Write Enable/Disable
You can write-protect your ARMC/2 card’s firmware so that it cannot be flashed. By
default, pins one and two are shorted so that you can flash the firmware.
Pin Description
1 VCC3
2 Write-Protect Enabled
3 Ground
Pin Description
1-2 Flash Write Enable
2-3 Flash Write Disable
Cont’d
ARMC/2 User’s Guide
6
Step 1 Unpack the ARMC/2 Card (and check jumper settings), Continued
JP12 Diagnostic and Recovery Mode Jumper
This jumper is primarily used to recover a failed flash attempt. By shorting pins one and
two, you can place your ARMC/2 card into Diagnostics Mode. By shorting pins two and
three, you can place your ARMC/2 card into Recovery Mode. See Appendix C, Remote
Recovery Application (RRA) for more information on how to recover your ARMC/2 card.
By default, pins one, two and three are open.
Pin Description
1 GP I/O PA7
2 Ground
3 GP I/O PA10
JP13 and JP14 PCI Bus SMB Data and Clock Jumper
These two headers allow your ARMC/2 card to read I2C bus information. If your hosts
system’s motherboard has support for I2C on the PCI slots, place a jumper on these two
headers. By default these headers are open.
Note: Only revision B1 and newer revisions of the ARMC/2 cards have these two jumpers.
Revisions A and B do not have JP13 and JP14.
Note: Most PCI slots have a “floating” I2C bus. A “floating” I2C bus means that there is no
physical connection between the two I2C pins on the PCI slot and the motherboard’s I2C
bus. Shorting JP13 and JP14 would be useless in this case.
Note: JP13 and JP14 can be used in place of the ARMC/2 Universal Cable to gather I2C bus
information from the motherboard.
Note: Only the OEM version can utilize the hardware health monitoring capabilities of
ARMC/2 card. The hardware health monitoring function requires an OEM specific cable
and Sensor Definition Kit (SDK/SDR) file and Soft Processor (SP) file.
Step 2 Plug in the ARMC/2 Card into the Host System and Attach Internal
Cables
Physically plug in the ARMC/2 card into any available PCI slot inside the host system.
J3 Service Connector
This jumper is used exclusively for servicing the ARMC/2 card. J3 is not described in
this document.
J4 JTAG (Joint Test Action Group) ICE (In-Circuit Emulator) Connector
This header is used to debug and service the ARMC/2 card. J4 is not described in this
document.
Cont’d
Chapter Two : Installing Your ARMC/2 Card
7
Step 2 Plug in the ARMC/2 Card into the Host System and Attach Internal
Cables,
Continued
J5 IPMB (Intelligent Platform Management Bus)
If your motherboard has an IPMB connector, you can connect a cable from J5 on the
ARMC/2 card to the IPMB connector on your motherboard.
Pin Description
1 Positive Signal
2 Ground
3 Negative Signal
IPMB (Intelligent Platform Management Bus)
The IPMI specification was developed by Intel, Dell, Hewlett-Packard, and NEC to
provide a standard interface to be used for monitoring server items such as temperature,
voltage, fans, power supplies, and chassis. IPMI is comprised of three specifications
Intelligent Platform Management Interface (IPMI), Intelligent Platform Management Bus
(IPMB) and Intelligent Chassis Management Bus (ICMB). The IPMI specification
defines the interface between management software and chassis management hardware.
The IPMB specification defines the internal Intelligent Platform Management Bus. The
ICMB specification defines an external bus for connecting additional IPMI enabled
systems.
The electrical interconnect for system management is based on the inter-IC (I2C) bus.
This bus is a two wire serial interface (clock, data) driven by open-collector drivers.
Devices arbitrate for the bus based on a collision detection mechanism. The I2C data and
I2C clock signals are referred to as an IPMB.
The IPMB connector can be used to read IPMI information from the motherboard's
System Management Controller. The format and definition of the IPMI information must
be based on the IPMI v1.5 Specification.
The IPMI specification was architected around the server motherboard environment. In a
typical motherboard, the Management Controller connects to a variety of dumb sensors
located on the motherboard and within the chassis. The command set contains commands
tailored to this environment and are intended to handle sensors, data repositories, event
logs and watchdog timers.
Cont’d
ARMC/2 User’s Guide
8
Step 2 Plug in the ARMC/2 Card into the Host System and Attach Internal
Cables,
Continued
J9 ARMC/2 Feature Connector
This feature connector is primarily used for operating the host system’s motherboard
power and reset switch. It can also be used to gather I2C bus information from the
motherboard.
Pin Description Pin Description
1 Not Connected 11 Reset_Host #
2 I2C Clock 12 Ground
3 Not Connected 13 Ground
4 Not Connected 14 Not Connected
5 Power_Off # 15 Not Connected
6 I2C Data 16 Ground
7 Not Connected 17 Not Connected
8 Not Connected 18 Not Connected
9 Not Connected 19 Not Connected
10 Not Connected 20 Ground
Note: JP13 and JP14 can be used in place of the ARMC/2 Universal Cable to gather I2C bus
information from the motherboard.
Note: JP4 and JP5 can be used in place of the ARMC/2 Universal Cable to power on, power off,
and power cycle the motherboard.
Note: JP7 and JP8 can be used in place of the ARMC/2 Universal Cable to reset the
motherboard.
Note: Only the OEM version can utilize the hardware health monitoring capabilities of
ARMC/2 card. The hardware health monitoring function requires an OEM specific cable
and Sensor Definition Kit (SDK/SDR) file and Soft Processor (SP) file.
Note: IPMI support is an OEM version feature.
Note: This cable is an optional component and must be custom made for your specific
configuration.
JP2 Serial Port Connector
You can connect an external 9 pin serial port connector to this header. This header is
primarily used to text redirect over the serial port.
JP3 Service Connector
This jumper is used exclusively for servicing the ARMC/2 card. JP3 is not described in
this document.
Cont’d
Chapter Two : Installing Your ARMC/2 Card
9
Step 2 Plug in the ARMC/2 Card into the Host System and Attach Internal
Cables,
Continued
JP4 and JP5 Chassis/Motherboard Power Switch
JP4 and JP5 can be used in place of the ARMC/2 Universal Cable to power on, power off,
and power cycle the motherboard.
Connect a two pin cable from the motherboard’s Power (Soft On/Off) header to JP4 on
your ARMC/2 card. Connect the chassis power switch to JP5 on your ARMC/2 card.
Note: JP4 and JP5 can be used in place of the ARMC/2 Universal Cable to power on, power
off, and power cycle the motherboard.
JP6 ARMC/2 Reset Button
You can short this jumper to reset your ARMC/2 card.
Pin Description
1 Ground
2 Reset #
JP7 and JP8 Chassis/Motherboard Reset Switch
JP7 and JP8 can be used in place of the ARMC/2 Universal Cable to reset the
motherboard.
Connect a two pin cable from the motherboard’s Reset header to JP7 on your ARMC/2
card. Connect the chassis reset switch to JP8 on your ARMC/2 card.
Note: JP7 and JP8 can be used in place of the ARMC/2 Universal Cable to reset the
motherboard.
Step 3 Connect External Cables
Connect the USB cable from the back of the ARMC/2 card to the motherboard’s
USB port.
Connect your VGA monitor to your ARMC/2 card.
Connect the RJ45 LAN cable from your local network to your ARMC/2 card.
Connect your AC adapter. (Only if the AC Adapter is part of your ARMC/2 kit)
Cont’d
ARMC/2 User’s Guide
10
Step 4 Confirm the Motherboard’s BIOS Settings
Power on the motherboard and enter the BIOS. Using the following table, confirm that
your motherboard’s BIOS settings are correct.
BIOS Section Setting
Boot Options> Removable Devices Virtual Floppy or USB Boot Device
Boot Options> ATAPI CDROM Virtual CDROM or USB Boot
Device
Advanced> PCIPnP> Configuration> Legacy USB Support Enable
Save the BIOS settings and restart the computer.
Note: Make sure that your motherboard BIOS supports Legacy USB devices, USB Boot or Boot
to USB.
Note: On some motherboards and server boards, depress the <CTRL>, <ALT>, and <ESC>
keys simultaneously to enter the BIOS. On others use the <F2> keys. See your server’s
documentation for more information on entering the BIOS setup.
Step 5 Install the Operating System and ARMC/2 Drivers
Step Action
1 Install the operating system (if applicable) on the host system.
2 (Windows 2000/2003 only) When prompted for the AMI Virtual Floppy drivers, install the ARMC/2
card’s AMI Virtual Floppy drivers located on the ARMC/2 CD in the INF folder.
3 (Windows 2000/2003 only) When prompted for the virtual CD-ROM drivers, install the Windows
default CD-ROM drivers.
Note: Do not use the amivirtfl.inf when prompted to install the virtual CD-ROM drivers. The
Virtual CD-ROM device does not require any special drivers. You can select the default option
Microsoft Windows provides.
Cont’d
Chapter Two : Installing Your ARMC/2 Card
11
Step 5 Install the Operating System and ARMC/2 Drivers, Continued
Installing Virtual Floppy Drivers on Microsoft® Windows Operating Systems
Microsoft® Windows 2000/2003 operating systems need an .INF for the AMI Virtual
Floppy device exposed by the ARMC/2 card.
Note: This installation procedure needs to be done one time only on the host system. Once the
Virtual Floppy is properly loaded, you can perform floppy redirection without going
through any extra steps.
Step Action
1 Microsoft® Windows 2000/2003 operating systems for the Virtual Floppy device .INF file the first
time you install the ARMC/2 card on the server.
Cont’d
ARMC/2 User’s Guide
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153

Acer ARMC_2 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI