  • Hello! I am an AI chatbot trained to assist you with the Munters ComDry-M160L Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Originalinstructions
Usermanual
ComDryM160L
Desiccantdehumidier
190TEN-1098-D1404©MuntersEuropeAB2014
Importantuserinformation
Intendeduse
Muntersdehumidiersareintendedtobeusedforthe
dehumidicationofair.Anyotheruseoftheunit,or
usewhichiscontrarytotheinstructionsgiveninthis
manual,cancausepersonalinjuryanddamagetotheunit
andotherproperty.
Nomodicationoftheunitisallowedwithoutprior
approvalbyMunters.Attachmentorinstallation
ofadditionaldevicesisonlyallowedafterwritten
agreementbyMunters.
Warranty
Thewarrantyperiodisvalidfromthedatetheunit
leftourfactory,unlessotherwisestatedinwriting.
Thewarrantyislimitedtoafreeexchangeofpartsor
componentswhichhavefailedasaresultofdefectsin
materialsorworkmanship.
Allwarrantyclaimsmustincludeproofthatthe
faulthasoccurredwithinthewarrantyperiodand
thattheunithasbeenusedinaccordancewiththe
specications.Allclaimsmustspecifytheunittypeand
fabricationnumber.Thisinformationisstampedonthe
identicationplate,seesectionMarking.
Itisaconditionofthewarrantythattheunitforthe
fullwarrantyperiodisservicedandmaintainedas
describedinsectionServiceandmaintenance.Theservice
andmaintenancemustbedocumentedforthewarranty
tobevalid.
Safety
Informationaboutdangersareinthismanualindicated
bythecommonhazardsymbol:
W W
W
ARNING! ARNING!
ARNING!
Indicatesapossibledangerthatcanleadtopersonalinjury.
CA CA
CA
UTION! UTION!
UTION!
Indicatesapossibledangerthatcanleadtodamagetothe
unitorotherproperty,orcauseenvironmentaldamage.
NOTE!Highlightssupplementaryinformationforoptimal
useoftheunit.
ConformitywithDirectives
Thedehumidierisinconformitywiththeessential
safetyrequirementsoftheMachineryDirective
2006/42/EC,theLowVoltageDirective2006/95/EC,
theRoHSDirective2011/65/ECandtheEMC
Directive2004/108/EC.Thedehumidieris
manufacturedbyanISO9001:2008accredited
manufacturingorganisation.
Copyright
Thecontentsofthismanualcanbechangedwithout
priornotice.
NOTE!Thismanualcontainsinformationwhichis
protectedbycopyrightlaws.Itisnotallowedtoreproduceor
transmitanypartofthismanualwithoutwrittenconsentfrom
Munters.
Pleasesendanycommentsregardingthismanualto:
MuntersEuropeAB
TechnicalDocumentation
P.O.Box1150
SE-16426KISTASweden
e-mail:t-doc@munters.se
iiImportantuserinformation190TEN-1098-D1404
Tableofcontents
Importantuserinformation...............ii
Intendeduse...........................
ii
Warranty...............................
ii
Safety..................................
ii
ConformitywithDirectives............
ii
Copyright..............................
ii
Tableofcontents...........................iii
1Introduction.................................1
1.1Aboutthismanual.....................
1
1.2Unintendeduse........................
1
1.3Safety..................................
1
1.4Marking................................
3
2Principleofoperation......................4
3Transport,inspectionandstorage.......5
3.1Transport..............................
5
3.2Inspectionofdelivery..................
5
3.3Storingtheequipment................
5
4Installation...................................6
4.1Safety..................................
6
4.2Closedsystem.........................
6
4.3Opensystem..........................
7
4.4Siterequirements.....................
7
4.5Installationoftheunit..................
8
4.6Ductsandhoses.......................
9
4.7Connectingthedrainhose............
9
4.8Electricalconnections................
10
4.9Expandingthesystem................
11
4.10Accessories...........................
12
5Controlpaneloverview....................13
6Operation....................................14
6.1Safety..................................
14
6.2Introduction............................
14
6.2.1Humiditycontrol................
14
6.2.2Fanmodes.....................
14
6.2.3Fanspeed......................
14
6.3Initiationandstart.....................
15
6.3.1Bootthecontrolsystem........
15
6.3.2Startthedehumidier..........
15
6.4Stopthedehumidier.................
16
6.5Emergency............................
16
6.6Automaticstartafterpowerfailure....
16
6.7Navigatethemenus...................
17
6.8Accessthecontrolsystem............
18
6.9Changethesystemsettings..........
19
6.10Resetanalarm........................
20
6.11Resetthecounters....................
21
6.12Serviceintervalalarm.................
22
6.13Restorethedefaultsettings...........
23
6.14Accesslevels..........................
23
7Menusandparameters....................24
7.1Humidity...............................
24
7.1.1Internalcontrollingsensor.....
25
7.1.2Externalcontrollingsensors..
25
7.2Runtime...............................
26
7.3Power..................................
27
7.4Temperature...........................
28
7.5Functions..............................
30
7.5.1Processfanspeed.............
30
7.5.2Processfanmode..............
30
7.5.3Humiditycontrolandunits.....
30
7.5.4Displayinformation............
31
7.6Alarm...................................
33
7.7Min,maxanddefaultvalues..........
34
7.7.1Humidity........................
34
7.7.2Servicetime....................
34
7.7.3Functions.......................
34
8Serviceandmaintenance.................35
8.1General................................
35
8.2Maintenanceschedule................
35
8.3Processairlterchange..............
36
9Faulttracing.................................37
10Technicalspecication....................39
10.1Dimensionsandservicespace.......
39
10.2Capacitydiagram.....................
40
10.3Fancurveprocessair.................
40
10.4T echnicaldata.........................
41
11Scrapping....................................42
12ContactMunters............................44
190TEN-1098-D1404Tableofcontentsiii
ComDryM160L
1Introduction
1.1Aboutthismanual
Thismanualiswrittenfortheuserofthedehumidier.Itcontainsnecessaryinformationforhowtoinstall
andusethedehumidierinasafeandefcientway.Readthroughthemanualbeforethedehumidieris
installedandused.
ContactyournearestMuntersofceifyouhaveanyquestionsregardingtheinstallationortheuseofyour
dehumidier.
Thismanualmustbestoredinapermanentlocationclosetothedehumidier.
1.2Unintendeduse
Thedehumidierisnotintendedforoutdoorinstallation.
Thedehumidierisnotintendedforuseinclassiedareaswhereexplosionsafetycompliantequipment
isrequired.
Thedehumidiermustnotbeinstallednearanyheatgeneratingdevicesthatcancausedamagetothe
equipment.
NOTE!Whenadehumidierisplacedinabuildingwithradonitisnecessarytocontactanexperttosecurethe
bestoverallsolution.Allchangesaffectingtheventilationorthepressurebalanceinthebuildingcanresultina
changedconcentrationofradon.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
1.3Safety
Everymeasurehasbeentakeninthedesignandmanufactureofthedehumidiertoensurethatitmeetsthe
safetyrequirementsofthedirectivesandstandardslistedintheECDeclarationofConformity.
Theinformationinthismanualshallinnowaytakeprecedenceoverindividualresponsibilitiesorlocal
regulations.
Duringoperationandotherworkwithamachineitisalwaystheresponsibilityoftheindividualtoconsider:
Thesafetyofallpersonsconcerned.
Thesafetyoftheunitandotherproperty.
Theprotectionoftheenvironment.
ThetypesofdangersthatareindicatedinthismanualaredescribedinsectionImportantuserinformation.
1Introduction190TEN-1098-D1404
ComDryM160L
W W
W
ARNING! ARNING!
ARNING!
-Theunitmustnotbesplashedwithorimmersedinwater.
-Allelectricalinstallationsmustbecarriedoutbyaqualiedelectricianandinaccordancewithlocalregulations.
-Theunitmustbeconnectedtoanearthedelectricaloutlet.
-Donotconnecttheunittoothermainsvoltagethanspeciedontheidenticationplate.
-Donotoperatetheunitifthepowerplugorcordisdamaged,riskofelectricalshock.
-Donotpulltheplugwithwethands,riskofelectricalshock.
-Donotinsertngersoranyotherobjectsintotheairvents,rotatingfansareinside.
-Donotcovertheunitasthatcanblockairintakeoroutletandcauseare.
-Iftheunithasoverturned,cutthepowerimmediately.
-AlwayscontactMuntersforserviceorrepair.
190TEN-1098-D1404Introduction2
ComDryM160L
1.4Marking
Figure1.1Identicationplateposition
Type
Fa br. No.
Fa br. ye a r
0,17 kW
Max 1,01 kW
1015 170XXX XXXXX
2010
ComDry M160L
0
0
·
·
230V 50/60 Hz
Ma de in S we de n
Munters Europe AB
Isa fjords ga ta n 1
164 26 Kista , S we de n
Weight: 17 kg
IP 33
0,84 kW
R
oHS
M
Figure1.2Identicationplate,anexample
Explanationof"Fabr.No."ontheidenticationplate:
10:Yearofmanufacture
15:Weekofmanufacture
170XXX:Articlenumber
XXXXX:Serialnumber
3Introduction190TEN-1098-D1404
ComDryM160L
2Principleofoperation
Thedesiccantrotoristheadsorptiondehumidifyingcomponentintheunit.Therotorstructureis
comprisedofalargenumberofsmallairchannels.
Thedesiccantrotorismadeofacompositematerialthatishighlyeffectiveinattractingandretainingwater
vapour.Therotorisdividedintwozones.Theairowtobedehumidied,processair,passesthroughthe
largestzoneoftherotorandthenleavestherotorasdryair.Sincetherotorrotatesslowly,theincomingair
alwaysmeetsadryzoneontherotor,thuscreatingacontinuousdehumidicationprocess.
Theairowthatisusedtodrytherotor,reactivationair,isheated.Thereactivationairpassesthrough
therotorintheoppositedirectiontotheprocessairandleavestherotoraswetair(warmhumidair).The
wetairre-circulatesthroughacondenserthatcoolsdowntheairtocondensethewaterusingapartofthe
processair.
Thecondensedwaterisdischargedbygravitythroughahose.
Thisprincipleenablesthedehumidiertoworkeffectively,evenatlowtemperaturesfrom±0°C.
1.Processair
2.Dryair
3.Coolingairout
1
3
2
Figure2.1Principleofoperation
190TEN-1098-D1404Principleofoperation4
ComDryM160L
3Transport,inspectionandstorage
3.1Transport
Beforemovingthedehumidier,makesurethereisnowaterleftinthedrainbypullingthedrainplugout.
CA CA
CA
UTION! UTION!
UTION!
Removethedrainpipefromthetraytoavoiddamage,seesection4.5,Installationoftheunit.
Transportthedehumidierbycarryingitbyitshandleorintheoriginalpackaging.Theunitmustalwaysbe
placedinanuprightpositionduringtransport.Failuretocomplywiththiscancausetheunittomalfunction.
Thepowercordshouldberolledupandplacedunderthehandlewhencarryingthedehumidier,see
Figure3.1.
Figure3.1Powercordplacement
3.2Inspectionofdelivery
1.Inspectthedeliveryandcomparewiththedeliverynote,orderconrmationorotherdelivery
documentation.Makesurethateverythingisincludedandnothingisdamaged.
2.ContactMuntersimmediatelyifthedeliveryisnotcompleteinordertoavoidinstallationdelays.
3.Iftheunitistobeputintostoragepriortoinstallation,seesectionStoringtheequipment.
4.Removeallpackagingmaterialfromtheunit,andmakesurethatnodamagehasoccurredduring
transportation.
5.AnyvisibledamagemustbereportedinwritingtoMunterswithin5daysandpriortoinstallationof
theunit.
6.Disposeofthepackagingmaterialaccordingtolocalregulations.
3.3Storingtheequipment
CA CA
CA
UTION! UTION!
UTION!
Alwaysunplugtheunitfromthepowersupplywhennotinuse.
Followtheseinstructionsifthedehumidieristobestoredpriortoinstallation:
Placethedehumidierinanuprightpositiononahorizontalsurface.
Re-usethepackagingmaterialtoprovideprotectionfortheunit.
Protectthedehumidierfromphysicaldamage.
Storethedehumidierundercoverandprotectitfromdust,frost,rainandaggressivecontaminants.
5Transport,inspectionandstorage190TEN-1098-D1404
ComDryM160L
4Installation
4.1Safety
W W
W
ARNING! ARNING!
ARNING!
Donotconnecttheunittoothermainsvoltagethanspeciedontheidenticationplate.
Theunitmustbeconnectedtoanearthedelectricaloutlet.
Donotoperatetheunitifthepowerplugorcordisdamaged.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
NOTE!Whenadehumidierisplacedinabuildingwithradonitisnecessarytocontactanexperttosecurethe
bestoverallsolution.Allchangesaffectingtheventilationorthepressurebalanceinthebuildingcanresultina
changedconcentrationofradon.
4.2Closedsystem
Thedehumidierisplacedinthespacetobedehumidied.Toensurethatthedryairisdistributedevenly
inthespacetobedehumidiedaductingcanbeconnectedtothedryairoutletofthedehumidier.The
condensedwaterisdrainedthroughahose.
Aclosedsystemispreferablewhenthereisaneedfordehumidicationtoaverydryclimate.Itismore
economicaltoruncomparedtoanopensystem.
1
2
C om D ry M 160L
3
Figure4.1Closedsystemprinciple
1.Process/Reactivationair
2.Dryair
3.Condensedwater
190TEN-1098-D1404Installation6
ComDryM160L
4.3Opensystem
Thedehumidierisplacedoutsidetheareatobedehumidied.Dryairistransportedwithductingtothe
spacetobedehumidied.Thecondensedwaterisdrainedthroughahose.Theinstallationisusedtosolve
thefollowingproblems:
-Whenmoisturedamagedobjectsaretobedehumidied.
-Dustorcorrosioncausingparticlesarepresentinaspacewheredryairwillbesupplied.
-Topreventmoisturefromenteringthedehumidiedspace/object.
2
1
3
C om D ry M 160L
Figure4.2,Opensystemprinciple
1.Process/Reactivationair
2.DryAir
3.Condensedwater
4.4Siterequirements
Thedehumidierisonlyintendedforindoorinstallation.Avoidinstallingthedehumidierinadamp
environmentwherethereisariskofwaterenteringtheunitorinaverydustyenvironment.Ifindoubt,
seekadvicefromMunters.Itisimportantthattheintendedinstallationsitemeetsthelocationandspace
requirementsfortheequipmentinordertoachievethebestpossibleperformanceandtrouble-free
operation.Forspacerequirements,seesection10.1,Dimensionsandservicespace.
7Installation190TEN-1098-D1404
ComDryM160L
4.5Installationoftheunit
ComDryM160Lisdesignedtobemountedonawallusingthewallbracketincludedinthedeliveryofthe
unit.Seetheseparatewallbracketleaet.
1.Assemblethethreemainpartsofthewallbracket.Seeitem1,2and3intheleaet.Usethefourscrews
included.
2.Markfourwallholesusingtheencloseddrillpattern.Makesuretogetatleast25cmspacebetweenthe
dehumidierandtheoor.
3.Usefourscrewswithamaximumdiameterof7mm(notincluded)tomountthebracketonthewall.
4.Screwthewallbracketontothewall.
5.Laydownthedehumidier.
1
2
Figure4.3Figure4.4
6.InserttheO-ring(1)intothedrainpipesleeve(2).PresstheO-ringsoitisproperlyseatedinthegroove
seeFigure4.3
7.Pushthedrainpipeontothedrainconnectionofthetray,seeFigure4.4
8.Fastenthedrainpipewiththetwoenclosedscrews.
9.Therearetwoslotsintheshelfenablingalashingstraptobemountedifthedehumidieristobexed
byastrap.
10.Alternativelythefourfeetcanbelockedsimplybychangingthescrewineachfoottoalonger(not
included)andusethefourpre-drilledholesinthebracket.Fournewwasherswillalsobeneeded.
11.Finallyputthehoseontothedrainpipeandlockthehoseusingahoseclamp.
12.Ifductsorhosesaretobeinstalled,seesection4.6,Ductsandhoses.
190TEN-1098-D1404Installation8
ComDryM160L
4.6Ductsandhoses
Wheninstallingductworkbetweenthedehumidierandtheinletandoutletconnections,thefollowing
recommendationsshouldbeobserved:
Ductlengthmustbekeptasshortaspossibletominimisestaticpressureloss.
Allductandhoseconnectionsmustbeairtightandvapourtighttoensurefullperformance.
Thetotalresistanceintheductworkmustnotexceedtheperformanceratingofthefansttedinthe
dehumidier.
NOTE!Maximumlengthofdryairhoseis25metres.
4.7Connectingthedrainhose
Beforeconnectingthedrainhosethedehumidiermustbemountedonthewallusingtheenclosedwall
bracket.Theminimumdistancebetweenthebottomofthedehumidierandtheooris25cm.
Figure4.5Drainhoseconnection
9Installation190TEN-1098-D1404
ComDryM160L
4.8Electricalconnections
Thedehumidierisdeliveredwitha2,7metrepowercable,equippedwithanearthedplug.Themain
electricalcomponentsareinstalledintheupperpartoftheunit.
CA CA
CA
UTION! UTION!
UTION!
Donotconnecttheunittoothermainsvoltagethanspeciedontheunit’sidenticationplate.
Themainsfrequencycanbeadjusted,seeTable7.5.
NOTE!Incaseofaxedinstallationwheretheplugisreplacedbyacircuitbreaker,checkthatthefuserating
inthecircuitbreakeriscorrect.
190TEN-1098-D1404Installation10
ComDryM160L
4.9Expandingthesystem
CA CA
CA
UTION! UTION!
UTION!
NeverconnectComDrydirectlytoastandardEthernetnetwork,eveniftheconnectortypeisthesame(RJ45-8,
modularconnector).DoingsomightdamageboththeComDrycontrolsystemand/orthecomputernetwork.
AllComDrydehumidiersareequippedwithtwoCANBUSports,locatedbehindacovernexttothe
applianceinlet.Anindoorremotecontrol,externalhumidity/temperaturesensorsoranexternalsignalbox
canbeconnectedtotheseCANBUSports.Itdoesnotmatterwhichoftheabovedeviceswillbeconnected
towhichport.Whennoportisusedthetwoemptyterminationplugsmustbettedtotheports.
Figure4.6RemovethecoverFigure4.7,2CANBUSportswithemptyplugstted
11Installation190TEN-1098-D1404
ComDryM160L
4.10Accessories
Therearesomeaccessoriesavailableasoptionstothedehumidier.
WallBracket.Astheunitmustbemountedonthewallthisisincludedinthesupply.
StubPipeKitisusedwhenthereisaneedtoconnectaninletductorhosetothedehumidier.
RemoteControlmakesitpossibletocontroltheunitfromdistance,deliveredwitha10metrecable.
Externalsignalboxisusedwhenthereisaneedtoconnecttoanexternalcontrolsystem.
RemoteRH/Tsensorforexternalmeasuringofhumidityandtemperature.
WallBracket
StubPipeKit
kWh
C
f
X
RemoteControl
Externalsignalbox
RemoteRH/Tsensor
190TEN-1098-D1404Installation12
ComDryM160L
5Controlpaneloverview
C
f
X
kWh
1
2
3
4
5
6
A
B
C
RH1 55%
*
Menuindicators1-6
1.Humiditymenu4.T emperaturemenuA.Alarmindicator
2.Timemenu5.FunctionsmenuB.Operationindicator
3.Powermenu6.AlarmmenuC.On/Offbutton
MenubuttonFunction
Up/Rightbutton
Enter/Conrmationbutton
Down/Leftbutton
Table5.1Menubuttonfunctions
13Controlpaneloverview190TEN-1098-D1404
ComDryM160L
6Operation
6.1Safety
W W
W
ARNING! ARNING!
ARNING!
Donotoperatetheunitifthepowerplugorcordisdamaged.
Donotinsertngersoranyotherobjectsintotheairvents.
Theunitcanrestartautomaticallywithoutwarningfollowingapowerfailure.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
6.2Introduction
6.2.1Humiditycontrol
TheComDrydehumidierisequippedwithasophisticatedmicroprocessorbasedcontrolsystem.This,in
combinationwiththebuilt-inhumidity/temperaturesensorintheprocessairinlet,makesitpossibletoset
boththecontrolandpresentationofthehumiditytoeitherrelativehumidity(RH%),dewpoint(Dp°C)or
absolutehumidity(Xgr/kg).Thecontrolsystemadditionallychecksthetemperaturesbeforeandafterthe
heater,aswellasinthewetairaftertherotor.Ahighsafetylevelisobtainedbyvarioustemperaturesensors.
Toohightemperaturesgivesareductionoftheheaterpower,whileexcessivetemperatureswillmakethe
systemissueanalarmandshutthedehumidierdowninacontrolledway.Forfurtherexplanation,see
7.1,Humidityand7.5,Functions.
NOTE!Thedehumidieralwaysoperatesinautomaticmode(moisturebasedoperation).Asdefaultitwilluse
thebuilt-inhumidity/temperaturesensor,asoptionanexternalsensor.
6.2.2Fanmodes
Dependingontheapplication,ifxedortemporarilyinstalledetc.,thedehumidiercanberunindifferent
processfanmodes:Fan“ON”(continuous),“INT”(INTermittent)or“DEM”(onDEMand).Forfurther
explanation,see7.5,Functions.
6.2.3Fanspeed
Therearethreeprocessfanspeedsettingsavailable:“HIGH”,“NORM”and“LOW”.Thespeedis
manuallysetbytheoperator.Forfurtherexplanation,see7.5,Functions.
190TEN-1098-D1404Operation14
ComDryM160L
6.3Initiationandstart
6.3.1Bootthecontrolsystem
Connectthedehumidiertomains.Result:ThecontrolsystemwillinitiatebyashingallLEDsforafew
seconds,andthedisplayrstshowstheComDrymachinetype[[M160L],thenthesetfrequency,e.g.[50Hz]
andnallythesoftwareversionnumber,e.g.[VER:1.00]andthecurrenthumiditylevel,e.g.[*RH146%].
NOTE!Thebootsequencetakesabout10seconds.Letthecontrolsystemnishthebootingbeforeattempting
tostartthedehumidier.
6.3.2Startthedehumidier
Followthesestepstostartthedehumidier:
StepActionIllustration
1PresstheOn/Offbutton(C)oncetostartthedehumidier.
Result:IfthemeasuredhumidityislowerthantheSetValue,
thegreenoperatingindicator(B)willstarttoashinalong
on/shortoffsequence.Dependingonfanmodesetting,the
processfanwillrunornot.Theunitisnowinstand-bymode.
C
B
2Thedehumidierstartstodehumidifywhenthemeasured
humidityisequalorgreaterthantheSetValue,andthe
operatingindicator(B)willshifttocontinuouslylit.
B
15Operation190TEN-1098-D1404
ComDryM160L
6.4Stopthedehumidier
CA CA
CA
UTION! UTION!
UTION!
Donotunplugthedehumidierwhileitiscoolingdown.Ifunpluggeditmightleadtopermanentunitdamage.
Followthesestepstostopthedehumidier:
Step
Action
Result/Illustration
1
PressOn/Offoncetostopthedehumidier.Thegreenoperatingindicatorstartsashing
withequallylongandshortonandoffperiods.
2
Theunitcontinuestorunforawhileinordertocooldownand
thenstops.
6.5Emergency
CA CA
CA
UTION! UTION!
UTION!
Onlyquickstopthedehumidierinthecaseofanemergency.Thefanstopsandtheheatercanbeveryhot,which
canresultindamagetotheheaterandothercomponentsclosetoit.
Incaseofemergency,stopthedehumidierbypullingthemainsplugor,ifitispermanentlyconnected
tomains,byusingtheexternalswitch.
6.6Automaticstartafterpowerfailure
Ifthedehumidierisswitchedonitwillreverttooperationafterapowerfailure,regardlessofifitwas
runningorinstand-by.
190TEN-1098-D1404Operation16
ComDryM160L
6.7Navigatethemenus
Thethreebuttons,andonthecontrolpanelmakeitpossibletonavigatethemenus.
Followthesestepstonavigatethemenus:
Step
Action
Result/Illustration
1
Toselectamenu,pressor.untiltheselectedmenuappears.
Theselectedmenuindicatorislit.
2
Toenterthemenu,press.
Themenuindicatorstarts
ashing.
f
X
3
Useortoscrollthroughthemenu.
4
Leavethemenubyusingandgoto[EXIT].
Press.
Themenuindicatorstops
ashing.
NOTE!Allmenulistsarecircular.Attheendofeachmenuyouwillnd
[
EXIT
]
.Thequickestwayofnavigating
thereistopress
onetimeafterhavingenteredamenu.
17Operation190TEN-1098-D1404
/