Munters ComDry-M160L Owner's manual

Category
Dehumidifiers
Type
Owner's manual
Originalinstructions
Usermanual
ComDryM160L
Desiccantdehumidier
190TEN-1098-D1404©MuntersEuropeAB2014
Importantuserinformation
Intendeduse
Muntersdehumidiersareintendedtobeusedforthe
dehumidicationofair.Anyotheruseoftheunit,or
usewhichiscontrarytotheinstructionsgiveninthis
manual,cancausepersonalinjuryanddamagetotheunit
andotherproperty.
Nomodicationoftheunitisallowedwithoutprior
approvalbyMunters.Attachmentorinstallation
ofadditionaldevicesisonlyallowedafterwritten
agreementbyMunters.
Warranty
Thewarrantyperiodisvalidfromthedatetheunit
leftourfactory,unlessotherwisestatedinwriting.
Thewarrantyislimitedtoafreeexchangeofpartsor
componentswhichhavefailedasaresultofdefectsin
materialsorworkmanship.
Allwarrantyclaimsmustincludeproofthatthe
faulthasoccurredwithinthewarrantyperiodand
thattheunithasbeenusedinaccordancewiththe
specications.Allclaimsmustspecifytheunittypeand
fabricationnumber.Thisinformationisstampedonthe
identicationplate,seesectionMarking.
Itisaconditionofthewarrantythattheunitforthe
fullwarrantyperiodisservicedandmaintainedas
describedinsectionServiceandmaintenance.Theservice
andmaintenancemustbedocumentedforthewarranty
tobevalid.
Safety
Informationaboutdangersareinthismanualindicated
bythecommonhazardsymbol:
W W
W
ARNING! ARNING!
ARNING!
Indicatesapossibledangerthatcanleadtopersonalinjury.
CA CA
CA
UTION! UTION!
UTION!
Indicatesapossibledangerthatcanleadtodamagetothe
unitorotherproperty,orcauseenvironmentaldamage.
NOTE!Highlightssupplementaryinformationforoptimal
useoftheunit.
ConformitywithDirectives
Thedehumidierisinconformitywiththeessential
safetyrequirementsoftheMachineryDirective
2006/42/EC,theLowVoltageDirective2006/95/EC,
theRoHSDirective2011/65/ECandtheEMC
Directive2004/108/EC.Thedehumidieris
manufacturedbyanISO9001:2008accredited
manufacturingorganisation.
Copyright
Thecontentsofthismanualcanbechangedwithout
priornotice.
NOTE!Thismanualcontainsinformationwhichis
protectedbycopyrightlaws.Itisnotallowedtoreproduceor
transmitanypartofthismanualwithoutwrittenconsentfrom
Munters.
Pleasesendanycommentsregardingthismanualto:
MuntersEuropeAB
TechnicalDocumentation
P.O.Box1150
SE-16426KISTASweden
e-mail:t-doc@munters.se
iiImportantuserinformation190TEN-1098-D1404
Tableofcontents
Importantuserinformation...............ii
Intendeduse...........................
ii
Warranty...............................
ii
Safety..................................
ii
ConformitywithDirectives............
ii
Copyright..............................
ii
Tableofcontents...........................iii
1Introduction.................................1
1.1Aboutthismanual.....................
1
1.2Unintendeduse........................
1
1.3Safety..................................
1
1.4Marking................................
3
2Principleofoperation......................4
3Transport,inspectionandstorage.......5
3.1Transport..............................
5
3.2Inspectionofdelivery..................
5
3.3Storingtheequipment................
5
4Installation...................................6
4.1Safety..................................
6
4.2Closedsystem.........................
6
4.3Opensystem..........................
7
4.4Siterequirements.....................
7
4.5Installationoftheunit..................
8
4.6Ductsandhoses.......................
9
4.7Connectingthedrainhose............
9
4.8Electricalconnections................
10
4.9Expandingthesystem................
11
4.10Accessories...........................
12
5Controlpaneloverview....................13
6Operation....................................14
6.1Safety..................................
14
6.2Introduction............................
14
6.2.1Humiditycontrol................
14
6.2.2Fanmodes.....................
14
6.2.3Fanspeed......................
14
6.3Initiationandstart.....................
15
6.3.1Bootthecontrolsystem........
15
6.3.2Startthedehumidier..........
15
6.4Stopthedehumidier.................
16
6.5Emergency............................
16
6.6Automaticstartafterpowerfailure....
16
6.7Navigatethemenus...................
17
6.8Accessthecontrolsystem............
18
6.9Changethesystemsettings..........
19
6.10Resetanalarm........................
20
6.11Resetthecounters....................
21
6.12Serviceintervalalarm.................
22
6.13Restorethedefaultsettings...........
23
6.14Accesslevels..........................
23
7Menusandparameters....................24
7.1Humidity...............................
24
7.1.1Internalcontrollingsensor.....
25
7.1.2Externalcontrollingsensors..
25
7.2Runtime...............................
26
7.3Power..................................
27
7.4Temperature...........................
28
7.5Functions..............................
30
7.5.1Processfanspeed.............
30
7.5.2Processfanmode..............
30
7.5.3Humiditycontrolandunits.....
30
7.5.4Displayinformation............
31
7.6Alarm...................................
33
7.7Min,maxanddefaultvalues..........
34
7.7.1Humidity........................
34
7.7.2Servicetime....................
34
7.7.3Functions.......................
34
8Serviceandmaintenance.................35
8.1General................................
35
8.2Maintenanceschedule................
35
8.3Processairlterchange..............
36
9Faulttracing.................................37
10Technicalspecication....................39
10.1Dimensionsandservicespace.......
39
10.2Capacitydiagram.....................
40
10.3Fancurveprocessair.................
40
10.4T echnicaldata.........................
41
11Scrapping....................................42
12ContactMunters............................44
190TEN-1098-D1404Tableofcontentsiii
ComDryM160L
1Introduction
1.1Aboutthismanual
Thismanualiswrittenfortheuserofthedehumidier.Itcontainsnecessaryinformationforhowtoinstall
andusethedehumidierinasafeandefcientway.Readthroughthemanualbeforethedehumidieris
installedandused.
ContactyournearestMuntersofceifyouhaveanyquestionsregardingtheinstallationortheuseofyour
dehumidier.
Thismanualmustbestoredinapermanentlocationclosetothedehumidier.
1.2Unintendeduse
Thedehumidierisnotintendedforoutdoorinstallation.
Thedehumidierisnotintendedforuseinclassiedareaswhereexplosionsafetycompliantequipment
isrequired.
Thedehumidiermustnotbeinstallednearanyheatgeneratingdevicesthatcancausedamagetothe
equipment.
NOTE!Whenadehumidierisplacedinabuildingwithradonitisnecessarytocontactanexperttosecurethe
bestoverallsolution.Allchangesaffectingtheventilationorthepressurebalanceinthebuildingcanresultina
changedconcentrationofradon.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
1.3Safety
Everymeasurehasbeentakeninthedesignandmanufactureofthedehumidiertoensurethatitmeetsthe
safetyrequirementsofthedirectivesandstandardslistedintheECDeclarationofConformity.
Theinformationinthismanualshallinnowaytakeprecedenceoverindividualresponsibilitiesorlocal
regulations.
Duringoperationandotherworkwithamachineitisalwaystheresponsibilityoftheindividualtoconsider:
Thesafetyofallpersonsconcerned.
Thesafetyoftheunitandotherproperty.
Theprotectionoftheenvironment.
ThetypesofdangersthatareindicatedinthismanualaredescribedinsectionImportantuserinformation.
1Introduction190TEN-1098-D1404
ComDryM160L
W W
W
ARNING! ARNING!
ARNING!
-Theunitmustnotbesplashedwithorimmersedinwater.
-Allelectricalinstallationsmustbecarriedoutbyaqualiedelectricianandinaccordancewithlocalregulations.
-Theunitmustbeconnectedtoanearthedelectricaloutlet.
-Donotconnecttheunittoothermainsvoltagethanspeciedontheidenticationplate.
-Donotoperatetheunitifthepowerplugorcordisdamaged,riskofelectricalshock.
-Donotpulltheplugwithwethands,riskofelectricalshock.
-Donotinsertngersoranyotherobjectsintotheairvents,rotatingfansareinside.
-Donotcovertheunitasthatcanblockairintakeoroutletandcauseare.
-Iftheunithasoverturned,cutthepowerimmediately.
-AlwayscontactMuntersforserviceorrepair.
190TEN-1098-D1404Introduction2
ComDryM160L
1.4Marking
Figure1.1Identicationplateposition
Type
Fa br. No.
Fa br. ye a r
0,17 kW
Max 1,01 kW
1015 170XXX XXXXX
2010
ComDry M160L
0
0
·
·
230V 50/60 Hz
Ma de in S we de n
Munters Europe AB
Isa fjords ga ta n 1
164 26 Kista , S we de n
Weight: 17 kg
IP 33
0,84 kW
R
oHS
M
Figure1.2Identicationplate,anexample
Explanationof"Fabr.No."ontheidenticationplate:
10:Yearofmanufacture
15:Weekofmanufacture
170XXX:Articlenumber
XXXXX:Serialnumber
3Introduction190TEN-1098-D1404
ComDryM160L
2Principleofoperation
Thedesiccantrotoristheadsorptiondehumidifyingcomponentintheunit.Therotorstructureis
comprisedofalargenumberofsmallairchannels.
Thedesiccantrotorismadeofacompositematerialthatishighlyeffectiveinattractingandretainingwater
vapour.Therotorisdividedintwozones.Theairowtobedehumidied,processair,passesthroughthe
largestzoneoftherotorandthenleavestherotorasdryair.Sincetherotorrotatesslowly,theincomingair
alwaysmeetsadryzoneontherotor,thuscreatingacontinuousdehumidicationprocess.
Theairowthatisusedtodrytherotor,reactivationair,isheated.Thereactivationairpassesthrough
therotorintheoppositedirectiontotheprocessairandleavestherotoraswetair(warmhumidair).The
wetairre-circulatesthroughacondenserthatcoolsdowntheairtocondensethewaterusingapartofthe
processair.
Thecondensedwaterisdischargedbygravitythroughahose.
Thisprincipleenablesthedehumidiertoworkeffectively,evenatlowtemperaturesfrom±0°C.
1.Processair
2.Dryair
3.Coolingairout
1
3
2
Figure2.1Principleofoperation
190TEN-1098-D1404Principleofoperation4
ComDryM160L
3Transport,inspectionandstorage
3.1Transport
Beforemovingthedehumidier,makesurethereisnowaterleftinthedrainbypullingthedrainplugout.
CA CA
CA
UTION! UTION!
UTION!
Removethedrainpipefromthetraytoavoiddamage,seesection4.5,Installationoftheunit.
Transportthedehumidierbycarryingitbyitshandleorintheoriginalpackaging.Theunitmustalwaysbe
placedinanuprightpositionduringtransport.Failuretocomplywiththiscancausetheunittomalfunction.
Thepowercordshouldberolledupandplacedunderthehandlewhencarryingthedehumidier,see
Figure3.1.
Figure3.1Powercordplacement
3.2Inspectionofdelivery
1.Inspectthedeliveryandcomparewiththedeliverynote,orderconrmationorotherdelivery
documentation.Makesurethateverythingisincludedandnothingisdamaged.
2.ContactMuntersimmediatelyifthedeliveryisnotcompleteinordertoavoidinstallationdelays.
3.Iftheunitistobeputintostoragepriortoinstallation,seesectionStoringtheequipment.
4.Removeallpackagingmaterialfromtheunit,andmakesurethatnodamagehasoccurredduring
transportation.
5.AnyvisibledamagemustbereportedinwritingtoMunterswithin5daysandpriortoinstallationof
theunit.
6.Disposeofthepackagingmaterialaccordingtolocalregulations.
3.3Storingtheequipment
CA CA
CA
UTION! UTION!
UTION!
Alwaysunplugtheunitfromthepowersupplywhennotinuse.
Followtheseinstructionsifthedehumidieristobestoredpriortoinstallation:
Placethedehumidierinanuprightpositiononahorizontalsurface.
Re-usethepackagingmaterialtoprovideprotectionfortheunit.
Protectthedehumidierfromphysicaldamage.
Storethedehumidierundercoverandprotectitfromdust,frost,rainandaggressivecontaminants.
5Transport,inspectionandstorage190TEN-1098-D1404
ComDryM160L
4Installation
4.1Safety
W W
W
ARNING! ARNING!
ARNING!
Donotconnecttheunittoothermainsvoltagethanspeciedontheidenticationplate.
Theunitmustbeconnectedtoanearthedelectricaloutlet.
Donotoperatetheunitifthepowerplugorcordisdamaged.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
NOTE!Whenadehumidierisplacedinabuildingwithradonitisnecessarytocontactanexperttosecurethe
bestoverallsolution.Allchangesaffectingtheventilationorthepressurebalanceinthebuildingcanresultina
changedconcentrationofradon.
4.2Closedsystem
Thedehumidierisplacedinthespacetobedehumidied.Toensurethatthedryairisdistributedevenly
inthespacetobedehumidiedaductingcanbeconnectedtothedryairoutletofthedehumidier.The
condensedwaterisdrainedthroughahose.
Aclosedsystemispreferablewhenthereisaneedfordehumidicationtoaverydryclimate.Itismore
economicaltoruncomparedtoanopensystem.
1
2
C om D ry M 160L
3
Figure4.1Closedsystemprinciple
1.Process/Reactivationair
2.Dryair
3.Condensedwater
190TEN-1098-D1404Installation6
ComDryM160L
4.3Opensystem
Thedehumidierisplacedoutsidetheareatobedehumidied.Dryairistransportedwithductingtothe
spacetobedehumidied.Thecondensedwaterisdrainedthroughahose.Theinstallationisusedtosolve
thefollowingproblems:
-Whenmoisturedamagedobjectsaretobedehumidied.
-Dustorcorrosioncausingparticlesarepresentinaspacewheredryairwillbesupplied.
-Topreventmoisturefromenteringthedehumidiedspace/object.
2
1
3
C om D ry M 160L
Figure4.2,Opensystemprinciple
1.Process/Reactivationair
2.DryAir
3.Condensedwater
4.4Siterequirements
Thedehumidierisonlyintendedforindoorinstallation.Avoidinstallingthedehumidierinadamp
environmentwherethereisariskofwaterenteringtheunitorinaverydustyenvironment.Ifindoubt,
seekadvicefromMunters.Itisimportantthattheintendedinstallationsitemeetsthelocationandspace
requirementsfortheequipmentinordertoachievethebestpossibleperformanceandtrouble-free
operation.Forspacerequirements,seesection10.1,Dimensionsandservicespace.
7Installation190TEN-1098-D1404
ComDryM160L
4.5Installationoftheunit
ComDryM160Lisdesignedtobemountedonawallusingthewallbracketincludedinthedeliveryofthe
unit.Seetheseparatewallbracketleaet.
1.Assemblethethreemainpartsofthewallbracket.Seeitem1,2and3intheleaet.Usethefourscrews
included.
2.Markfourwallholesusingtheencloseddrillpattern.Makesuretogetatleast25cmspacebetweenthe
dehumidierandtheoor.
3.Usefourscrewswithamaximumdiameterof7mm(notincluded)tomountthebracketonthewall.
4.Screwthewallbracketontothewall.
5.Laydownthedehumidier.
1
2
Figure4.3Figure4.4
6.InserttheO-ring(1)intothedrainpipesleeve(2).PresstheO-ringsoitisproperlyseatedinthegroove
seeFigure4.3
7.Pushthedrainpipeontothedrainconnectionofthetray,seeFigure4.4
8.Fastenthedrainpipewiththetwoenclosedscrews.
9.Therearetwoslotsintheshelfenablingalashingstraptobemountedifthedehumidieristobexed
byastrap.
10.Alternativelythefourfeetcanbelockedsimplybychangingthescrewineachfoottoalonger(not
included)andusethefourpre-drilledholesinthebracket.Fournewwasherswillalsobeneeded.
11.Finallyputthehoseontothedrainpipeandlockthehoseusingahoseclamp.
12.Ifductsorhosesaretobeinstalled,seesection4.6,Ductsandhoses.
190TEN-1098-D1404Installation8
ComDryM160L
4.6Ductsandhoses
Wheninstallingductworkbetweenthedehumidierandtheinletandoutletconnections,thefollowing
recommendationsshouldbeobserved:
Ductlengthmustbekeptasshortaspossibletominimisestaticpressureloss.
Allductandhoseconnectionsmustbeairtightandvapourtighttoensurefullperformance.
Thetotalresistanceintheductworkmustnotexceedtheperformanceratingofthefansttedinthe
dehumidier.
NOTE!Maximumlengthofdryairhoseis25metres.
4.7Connectingthedrainhose
Beforeconnectingthedrainhosethedehumidiermustbemountedonthewallusingtheenclosedwall
bracket.Theminimumdistancebetweenthebottomofthedehumidierandtheooris25cm.
Figure4.5Drainhoseconnection
9Installation190TEN-1098-D1404
ComDryM160L
4.8Electricalconnections
Thedehumidierisdeliveredwitha2,7metrepowercable,equippedwithanearthedplug.Themain
electricalcomponentsareinstalledintheupperpartoftheunit.
CA CA
CA
UTION! UTION!
UTION!
Donotconnecttheunittoothermainsvoltagethanspeciedontheunit’sidenticationplate.
Themainsfrequencycanbeadjusted,seeTable7.5.
NOTE!Incaseofaxedinstallationwheretheplugisreplacedbyacircuitbreaker,checkthatthefuserating
inthecircuitbreakeriscorrect.
190TEN-1098-D1404Installation10
ComDryM160L
4.9Expandingthesystem
CA CA
CA
UTION! UTION!
UTION!
NeverconnectComDrydirectlytoastandardEthernetnetwork,eveniftheconnectortypeisthesame(RJ45-8,
modularconnector).DoingsomightdamageboththeComDrycontrolsystemand/orthecomputernetwork.
AllComDrydehumidiersareequippedwithtwoCANBUSports,locatedbehindacovernexttothe
applianceinlet.Anindoorremotecontrol,externalhumidity/temperaturesensorsoranexternalsignalbox
canbeconnectedtotheseCANBUSports.Itdoesnotmatterwhichoftheabovedeviceswillbeconnected
towhichport.Whennoportisusedthetwoemptyterminationplugsmustbettedtotheports.
Figure4.6RemovethecoverFigure4.7,2CANBUSportswithemptyplugstted
11Installation190TEN-1098-D1404
ComDryM160L
4.10Accessories
Therearesomeaccessoriesavailableasoptionstothedehumidier.
WallBracket.Astheunitmustbemountedonthewallthisisincludedinthesupply.
StubPipeKitisusedwhenthereisaneedtoconnectaninletductorhosetothedehumidier.
RemoteControlmakesitpossibletocontroltheunitfromdistance,deliveredwitha10metrecable.
Externalsignalboxisusedwhenthereisaneedtoconnecttoanexternalcontrolsystem.
RemoteRH/Tsensorforexternalmeasuringofhumidityandtemperature.
WallBracket
StubPipeKit
kWh
C
f
X
RemoteControl
Externalsignalbox
RemoteRH/Tsensor
190TEN-1098-D1404Installation12
ComDryM160L
5Controlpaneloverview
C
f
X
kWh
1
2
3
4
5
6
A
B
C
RH1 55%
*
Menuindicators1-6
1.Humiditymenu4.T emperaturemenuA.Alarmindicator
2.Timemenu5.FunctionsmenuB.Operationindicator
3.Powermenu6.AlarmmenuC.On/Offbutton
MenubuttonFunction
Up/Rightbutton
Enter/Conrmationbutton
Down/Leftbutton
Table5.1Menubuttonfunctions
13Controlpaneloverview190TEN-1098-D1404
ComDryM160L
6Operation
6.1Safety
W W
W
ARNING! ARNING!
ARNING!
Donotoperatetheunitifthepowerplugorcordisdamaged.
Donotinsertngersoranyotherobjectsintotheairvents.
Theunitcanrestartautomaticallywithoutwarningfollowingapowerfailure.
CA CA
CA
UTION! UTION!
UTION!
Donotsit,stand,orplaceanyobjectsontheunit.
6.2Introduction
6.2.1Humiditycontrol
TheComDrydehumidierisequippedwithasophisticatedmicroprocessorbasedcontrolsystem.This,in
combinationwiththebuilt-inhumidity/temperaturesensorintheprocessairinlet,makesitpossibletoset
boththecontrolandpresentationofthehumiditytoeitherrelativehumidity(RH%),dewpoint(Dp°C)or
absolutehumidity(Xgr/kg).Thecontrolsystemadditionallychecksthetemperaturesbeforeandafterthe
heater,aswellasinthewetairaftertherotor.Ahighsafetylevelisobtainedbyvarioustemperaturesensors.
Toohightemperaturesgivesareductionoftheheaterpower,whileexcessivetemperatureswillmakethe
systemissueanalarmandshutthedehumidierdowninacontrolledway.Forfurtherexplanation,see
7.1,Humidityand7.5,Functions.
NOTE!Thedehumidieralwaysoperatesinautomaticmode(moisturebasedoperation).Asdefaultitwilluse
thebuilt-inhumidity/temperaturesensor,asoptionanexternalsensor.
6.2.2Fanmodes
Dependingontheapplication,ifxedortemporarilyinstalledetc.,thedehumidiercanberunindifferent
processfanmodes:Fan“ON”(continuous),“INT”(INTermittent)or“DEM”(onDEMand).Forfurther
explanation,see7.5,Functions.
6.2.3Fanspeed
Therearethreeprocessfanspeedsettingsavailable:“HIGH”,“NORM”and“LOW”.Thespeedis
manuallysetbytheoperator.Forfurtherexplanation,see7.5,Functions.
190TEN-1098-D1404Operation14
ComDryM160L
6.3Initiationandstart
6.3.1Bootthecontrolsystem
Connectthedehumidiertomains.Result:ThecontrolsystemwillinitiatebyashingallLEDsforafew
seconds,andthedisplayrstshowstheComDrymachinetype[[M160L],thenthesetfrequency,e.g.[50Hz]
andnallythesoftwareversionnumber,e.g.[VER:1.00]andthecurrenthumiditylevel,e.g.[*RH146%].
NOTE!Thebootsequencetakesabout10seconds.Letthecontrolsystemnishthebootingbeforeattempting
tostartthedehumidier.
6.3.2Startthedehumidier
Followthesestepstostartthedehumidier:
StepActionIllustration
1PresstheOn/Offbutton(C)oncetostartthedehumidier.
Result:IfthemeasuredhumidityislowerthantheSetValue,
thegreenoperatingindicator(B)willstarttoashinalong
on/shortoffsequence.Dependingonfanmodesetting,the
processfanwillrunornot.Theunitisnowinstand-bymode.
C
B
2Thedehumidierstartstodehumidifywhenthemeasured
humidityisequalorgreaterthantheSetValue,andthe
operatingindicator(B)willshifttocontinuouslylit.
B
15Operation190TEN-1098-D1404
ComDryM160L
6.4Stopthedehumidier
CA CA
CA
UTION! UTION!
UTION!
Donotunplugthedehumidierwhileitiscoolingdown.Ifunpluggeditmightleadtopermanentunitdamage.
Followthesestepstostopthedehumidier:
Step
Action
Result/Illustration
1
PressOn/Offoncetostopthedehumidier.Thegreenoperatingindicatorstartsashing
withequallylongandshortonandoffperiods.
2
Theunitcontinuestorunforawhileinordertocooldownand
thenstops.
6.5Emergency
CA CA
CA
UTION! UTION!
UTION!
Onlyquickstopthedehumidierinthecaseofanemergency.Thefanstopsandtheheatercanbeveryhot,which
canresultindamagetotheheaterandothercomponentsclosetoit.
Incaseofemergency,stopthedehumidierbypullingthemainsplugor,ifitispermanentlyconnected
tomains,byusingtheexternalswitch.
6.6Automaticstartafterpowerfailure
Ifthedehumidierisswitchedonitwillreverttooperationafterapowerfailure,regardlessofifitwas
runningorinstand-by.
190TEN-1098-D1404Operation16
ComDryM160L
6.7Navigatethemenus
Thethreebuttons,andonthecontrolpanelmakeitpossibletonavigatethemenus.
Followthesestepstonavigatethemenus:
Step
Action
Result/Illustration
1
Toselectamenu,pressor.untiltheselectedmenuappears.
Theselectedmenuindicatorislit.
2
Toenterthemenu,press.
Themenuindicatorstarts
ashing.
f
X
3
Useortoscrollthroughthemenu.
4
Leavethemenubyusingandgoto[EXIT].
Press.
Themenuindicatorstops
ashing.
NOTE!Allmenulistsarecircular.Attheendofeachmenuyouwillnd
[
EXIT
]
.Thequickestwayofnavigating
thereistopress
onetimeafterhavingenteredamenu.
17Operation190TEN-1098-D1404
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Munters ComDry-M160L Owner's manual