TH-1

Amprobe TH-1 User manual

  • Hello! I am an AI chatbot trained to assist you with the Amprobe TH-1 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TH-1
Relative Humidity /
Temperature Probe
Style Meter
Users Manual
•Moded’emploi
•Bedienungshandbuch
•Manualed’Uso
•Manualdeuso
•Användarhandbok
English
TH-1
RelativeHumidity/Temperature
ProbeStyleMeter
UsersManual
TH1_Rev002
©2012AmprobeTestTools.
Allrightsreserved.
2
Limited Warranty and Limitation of Liability
YourAmprobeproductwillbefreefromdefectsinmaterialand
workmanshipfor1yearfromthedateofpurchaseunlesslocallaws
requireotherwise.Thiswarrantydoesnotcoverfuses,disposable
batteriesordamagefromaccident,neglect,misuse,alteration,
contamination,orabnormalconditionsofoperationorhandling.
Resellersarenotauthorizedtoextendanyotherwarrantyon
Amprobe’sbehalf.Toobtainserviceduringthewarrantyperiod,
returntheproductwithproofofpurchasetoanauthorizedAmprobe
TestToolsServiceCenterortoanAmprobedealerordistributor.See
RepairSectionfordetails.THISWARRANTYISYOURONLYREMEDY.
ALLOTHERWARRANTIES-WHETHEREXPRESS,IMPLIEDORSTAUTORY
-INCLUDINGIMPLIEDWARRANTIESOFFITNESSFORAPARTICULAR
PURPOSEORMERCHANTABILITY,AREHEREBYDISCLAIMED.
MANUFACTURERSHALLNOTBELIABLEFORANYSPECIAL,INDIRECT,
INCIDENTALORCONSEQUENTIALDAMAGESORLOSSES,ARISING
FROMANYCAUSEORTHEORY.Sincesomestatesorcountriesdo
notallowtheexclusionorlimitationofanimpliedwarrantyorof
incidentalorconsequentialdamages,thislimitationofliabilitymaynot
applytoyou.
Repair
Alltesttoolsreturnedforwarrantyornon-warrantyrepairorfor
calibrationshouldbeaccompaniedbythefollowing:yourname,
company’sname,address,telephonenumber,andproofofpurchase.
Additionally,pleaseincludeabriefdescriptionoftheproblemorthe
servicerequestedandincludethetestleadswiththemeter.Non-
warrantyrepairorreplacementchargesshouldberemittedinthe
formofacheck,amoneyorder,creditcardwithexpirationdate,ora
purchaseordermadepayabletoAmprobe®TestTools.
In-Warranty Repairs and Replacement – All Countries
Pleasereadthewarrantystatementandcheckyourbatterybefore
requestingrepair.Duringthewarrantyperiodanydefectivetest
toolcanbereturnedtoyourAmprobe®TestToolsdistributorforan
exchangeforthesameorlikeproduct.Pleasecheckthe“Whereto
Buy”sectiononwww.amprobe.comforalistofdistributorsnearyou.
Additionally,intheUnitedStatesandCanadaIn-Warrantyrepairand
replacementunitscanalsobesenttoaAmprobe®TestToolsService
Center(seeaddressnextpage).
Non-Warranty Repairs and Replacement – US and Canada
Non-warrantyrepairsintheUnitedStatesandCanadashouldbesent
toaAmprobe®TestToolsServiceCenter.CallAmprobe®TestToolsor
inquireatyourpointofpurchaseforcurrentrepairandreplacement
rates.
InUSA InCanada
AmprobeTestTools AmprobeTestTools
Everett,WA98203 Mississauga,ONL4Z1X9
Tel:877-AMPROBE(267-7623) Tel:905-890-7600
Non-Warranty Repairs and Replacement – Europe
Europeannon-warrantyunitscanbereplacedbyyourAmprobe®Test
Toolsdistributorforanominalvcharge.Pleasecheckthe“Whereto
Buy”sectiononwww.amprobe.comforalistofdistributorsnearyou.
EuropeanCorrespondenceAddress*
Amprobe®TestToolsEurope
Beha-AmprobeGmbH
IndenEngematten14
79286Glottertal,Germany
Tel.:+49(0)76848009-0
www.amprobe.eu
*(Correspondenceonly–norepairorreplacementavailablefromthis
address.Europeancustomerspleasecontactyourdistributor.)
3
LCDDualDisplay
Probewithprotectiveturnablecap
ON/OFF
DataHOLD
MIN/MAX
RESET
MODE
°C/°FPushbutton
4
TH-1
Relative Humidity / Temperature Probe
Style Meter
CONTENTS
Symbols...................................................................................................... 5
Introduction............................................................................................... 5
UnpackandInspection........................................................................ 5
Operation.................................................................................................. 5
AutoPowerOff.................................................................................... 5
BatteryReplacement................................................................................. 6
Troubleshooting........................................................................................ 6
Specications............................................................................................. 6
5
SYMBOLS
Refertothemanual
ComplieswithEU
directives
Conformstorelevant
Australianstandards.
Donotdispose
ofthisproductas
unsortedmunicipal
waste.
Warning and Precautions
Do not put the probe in contact with liquids. That may cause
permanent damage.
INTRODUCTION
CongratulationsonyourpurchaseoftheTH-1temperatureprobestyle
meter.Thismeterisequippedwithaprotectiveturnablesensorcap,a
patenteddesign,toprotectthesensorwhennotinuse.
Aconvenientinstrumenttomeasuretemperaturefrom-20°Cto60°C
(4°to140°F),RelativeHumidityupto99%RH,andthedewpoint(DP)
orwetbulb(WB)fortemperatureandhumidity.
Unpack and Inspection
1xTH-1TemperatureProbestylemeter
1xBatteryCR2032
1xManual
OPERATION
1. Beforeyoustartanymeasurement,pleaserotatethecapclockwise
orcounterclockwisetoexposethesensor.
2. PressON/OFFyellowpushbuttontoturnpowerONorOFF.Youwill
seeafulldisplayonthescreenforonesecond.(SeeFig.1)Themeter
willstartmeasuringthetemperatureandhumidityanddisplayboth
readingsatthesametime.(SeeFig.2)
3. PressHOLDuntil“HLD”appearsonthescreentofreezethereading
onthedisplay.PressHOLDagaintocanceltheHOLDfunctionand
continuewiththemeasurement.(SeeFIG.3)
4. PressMIN/MAXtodisplaytheminimumreadingoftheactual
measurement(Temp&RH).PressMIN/MAXagaintodisplaythe
maximumreading.PressMIN/MAXagaintoreturntherealtime
measurement.(SeeFig.4)
5. Press°C/°FpushbuttontoswitchbetweendegreesCelsiusto
degreesFahrenheit.
6. PressMODEtotogglebetween“AIR”,“DP”,and“WB”readings.
7. PressandholdRESETtoclearcurrentMINandMAXreadingsfrom
memory
Auto Power Off
Themeterwillturnitselfoffafter20-min.TooverrideAutoPowerOff
function,pressON/OFF&HOLDkeyssimultaneously.Thedisplaywill
show”n”.When”n”appears,releasetheON/OFFbutton.Themeter
willnowbeinNon-sleepmodeforlongtimeoperationpurposes.(See
Fig.5)
6
BATTERY REPLACEMENT
1. Turnoffthemeter.Useacointoopenthebatterycover.
2. Putthebattery(CR2032)withthe”+”facesup.
3. Replacethecover.
TROUBLESHOOTING
POWERONBUTNODISPLAY
• Makesureyoupressthe”ON/OFF”keyformorethan100mS.
• Checkthebatteryconditionsandreplaceifnecessary
DISPLAYDISAPPEARS
• Checkforlowbatteryindicatorbeforethedisplayisoff.Ifthelow
batteryindicatorappears,replacethebattery.
• Turnonthemeterbypressing“ON/OFF+HOLD”keystodisable
AutoPowerOff.
E02-Outofthelowestlimit.
E03-Outofthehighestlimit.
E04-Checkerrormessageoftheoriginaldata.
E11-Calibrationrequired.Thehumiditysensoraccuracycannotbe
calibratedbytheuserduetospecialproceduresrequired.Please
contactaqualiedcalibrationhouseforservice.
E33-Returnthemeterforrepair
SPECIFICATIONS
Size:17.5×4.2×1.6cm(6.89x1.65x0.63in)
Battery:150Hours
Powerconsumption:<2.0mA
Sensor:ElectronicCapacitancePolymerFilmSensor
Range:
RelativeHumidity:0to100%
Temperature:-20to50°C(-4to122°F)
DP/WB:-20to59.9°C/-5to59.9°C(-4to139.8°F/23to139.8°F)
Accuracy:
RelativeHumidity:±4%from10to95%RHand±5%forotherRH
range@25°C/77°F
TemperatureCoefcient:0.1x(speciedaccuracy)/°C(<25°Cor>
25°C)
Temperature:±0.6°C/±1°F
Resolution:0.1%,0.1°C/0.1°F
Themeterconformstothefollowingstandards:
EN50081-1/1992:EN55022
EN50082-1/1997:EN55024
(EN61000-4-2/-3/-8,ENV50204)
38
FIG-4
Press MIN/MAX
Press MIN/MAX
Again
Press MIN/MAX
Again
Figure4
Figure5
FIG-5
PleaseRecycle
Visit www.Amprobe.com for
•Catalog
•Applicationnotes
•Productspecications
•Usermanuals
/