Page 9
English
induSENSOR, EDS, model F
Measuring Principle4.
0
1/1
4
12
20
Output signal (mA)
Measuring range
1/2
Sensor rod
Alu tube
Sensor
housing
Measuring Principle of an eddy current long stroke dis-Fig. 1
placement sensor, alu tube is shown at the start of the measu-
ring range
Electrical Connection5.
Connector 5-pins, CA02COM-E14S with bayonet connection
Unpacking, Shipping6.
Do not take and hold the sensor
at the sensor rod.
Check for completeness and ship-
ping damage immediately after
unpacking.
Installation and Assembly7.
Measuring Tube Guide and Fastening7.1
Mount the measuring tube in the piston borehold.
The dimensions for the measuring tube, see Fig. 4. When the piston
is moved in the measuring tube must not touch the sensor shaft.
Observe the measuring tube position at the zero point (= 4 mA out-
put), see Fig. 2. A slightly eccentric mounting of the measuring tube
has no negative influence on the sensor signal.
Mount the measuring tube in the piston by means of pressing
or glueing.
Spot clamping is not permissable.
i
The specified technical data are valid only if the
measuring tube is used supplied by MICRO-EPSILON!
Fig. 2 Zero point of the measuring tube
Measuring
range
100 160 200 250 300 400 630
Dimension a
20
(0.79)
20
(0.79)
20
(0.79)
20
(0.79)
20
(0.79)
25
(0.98)
25
(0.98)