Belmont PHOT-xII Sub-controller Template

  • I've reviewed the provided document, which serves as a wall mounting template for the Belmont Sub Controller PHOT-X II 303. This document includes key details such as mounting dimensions, hole placements, load-bearing requirements, recommended wiring, and installation height from the floor. Feel free to ask me any questions you have regarding the installation or specifications of this device.
  • What shear load must the wall withstand?
    What type of wire is recommended for interconnecting the main and sub controllers?
    What is the maximum recommended wire run distance?
    What is the recommended mounting height above the finished floor?
5mm
Mounting plateCover
40mm (1-9/16”) 40mm (1-9/16”)
16.5 mm
(5/8”)
124 mm (4-7/8”)
67.5 mm (2-5/8”)48 mm (1-7/8”)
155 mm (6-1/8”)
185mm (7-5/16”)
Sub Controller Wall Mounting Template
When mounting the model 303 sub controller, the wall and mounting
hardware must be sucient to withstand a 10 pound (45kg) shear load.
For interconnecting wiring between main controller and sub controller,
4 conductor, 20 AWG, 300V is recommended. Maximum wire run distance
is 33 feet (10m).
Recommended heights above the nished oor is 51-5/8" (1310mm).
/