CKD MEVT-T9GAR series User manual

Type
User manual
-
-
Please read this instruction manual
carefully before using this product, par-
ticularly the section describing safety
Retain this instruction manual with the
product for further consultation whenev-
er necessary
1
To use this product safety, basic knowledge of pneumatic
equipment, including materials, piping, electrical system
and mechanism, is required (ISO 4414 *1 JIS B 8370 *2).
We do not bear any responsibility for accidents caused by
any person without such knowledge or arising from im-
proper operation.
Our customers use this product for a very wide range of
applications, and we cannot keep track of all of them. De-
pending on operating conditions, the product may fail to
operate to maximum performance, or cause an accident.
Thus, before placing an order, examine whether the product
meets your application, requirements, and how to use it.
This product incorporates many functions and mecha-
nisms to ensure safety. However, improper operation could
result in an accident. To prevent such accidents
Observe the cautions on handling described in this manu-
al, as well as the following instructions:
Additionally, the caution is classified into the following
three groups, “CAUTION”, “WARNING”, and DANGER”,
to identify the degree of the danger it presents and possible
hazard.
*1) ISO 4414 : Pneumatic fluid power Recommendations for
the application of equipment to transmission and
control systems.
*2) JIS B 8370 : General rule for pneumatic systems
2
Points to caution when handling the product
(1) Inferior quality air will deteriorate the product characteristics and affect its
durability badly. Use an air dryer, filter and Oil mist filter to eliminate solid
material, moisture and tar and thus provide clean air from the pressure
source.
When the control pressure decreases, for example, the air runs from the sec-
ondary side through the regulator to the exhaust port (R). Dust inside the
secondary side piping or the load circuit, therefore, will similarly deteriorate
the products characteristics and greatly affect its durability. Ensure the in-
terior of the piping is always clean.
(2) The products response capability will be affected by the working pressure
and load volume. When a stable response is required, regulate the
working pressure.
(3) Flush air into the pneumatic pipes employed in the PARECT
electro-pneumatic regulator before connection. Be careful not to allow
sealant tape to stray into the pipes.
(4) To avoid malfunction caused by electrical noise:
(a) Insert a line filter into the AC power line.
(b) Use a surge suppresser like a CR or diode in the inductive load (solenoid valve, relay and
so on) to remove any noise at the source.
(c) Keep the MEVT series cables as far away as possible from power line for motor.
(d) In the case of the influence of noise, each slave station can possibly be supplied the power
and wire individually.
(e) Wire the power line as short as possible.
(f) Don’t share the power with devices that generate the noise, such as inverter motor.
(g) Don’t wire the power line or communication line in parallel with other lines.
(5) Avoid unplanned dismantling of the product. We shall not warrant the
product operation in cases where it has been dismantled without
authorization.
(6) Avoid operating the product in places where it may be affected by direct
sunlight, water or oil.
(7) If the product remains connected to its supply pressure for a long time
while leaving the power turned off, the output pressure may increase to the
level of the supply pressure. For safety, when there is a problem, use the
valve on either the inlet or outlet side. It is recommended to set up the
system for safe operation.
Air filter
5m
Air dryer Oil mist filter
(Oil removing)
Pressure switch
Regulator
3
(8) If the power is turned off when the unit is up to control pressure, the pres-
sure will be maintained. In this case, if you need to be in an exhaust state,
lower the control pressure first and then turn off the power or use the ex-
haust valve. However, the maintained pressure is not guaranteed to last for
very long.
(9) Since the working pressure is supposed to provide the exact control pres-
sure, it is important for the working pressure not to drop below “Control
pressure + Maximum control pressure 0.1”.
In particular, if the primary pressure is supplied for a long period of time
with the secondary pressure specified in a range that exceeds 0MPa up to
12% F.S., this will shorten the life span of the product and thus the product
should not be used in this way.
(10) The MEVT Series regulators may oscillate if a leak occurs to the secondary
side piping. When connecting pipes to the regulator, connect them firmly
to prevent leaks. Do not use the regulator for blowing or in any other ap-
plication where the secondary side can be affected by back pressure. If
used in such applications, the regulator will not be able to achieve the spec-
ified pressure. Moreover, a large oscillation noise will be heard and the
product’s durability will be greatly reduced.
(11) Don’t supply the input signal over maximum control pressure, because an
excessive input signal exerts a bad influence on the deterioration of the
characteristic and also the durability.
(12) Keep the exhaust port (R) open to the air to allow the release of the exhaust
into the air.
(13) When it is maintained the condition where the power is on and the working
pressure isn’t supplied or the condition where the power is on and the input
signal is missing from the control range, the deterioration of the character-
istic and also life occur. Therefore, the product should not be used in this
way.
4
INDEX
MEVT Series
PARECT Electro-pneumatic Regulator
SERIAL TRANSMISSION TYPE (MEVT-T9GAR)
Manual No. SM-312366-A
1. DESIGN AND SELECTION  5
2. INSTALLATION  8
3. OPERATION  12
4. MAINTENANCE  14
5. PRODUCTS
5.1 General outline of the system 15
5.2 Structure of the System  16
5.3 Specifications  17
5.4 Dimensions  21
5.5 Switch and LED display  23
5.6 Inside structure  27
5.7 Component  27
5.8 Block constitution  28
5.9 Troubleshooting the slave station  29
6. WIRING  30
6.1 Communication line  31
6.2 Transmission distance  31
6.3 Communication line wiring  35
6.4 Power line wiring  37
6.5 Screw and tightening torque  39
6.6 Maintenance 39
7. HOW TO EXTEND EVT  40
8. PRODUCT CODE
8.1 How to order  43
8.2 Component code  44
5
6
7
8
.
9
10
11
12
Operating Conditions:
The pressure supplied to the electro-pneumatic regulator should be used in
the pressure range from the minimum operating pressure to maximum oper-
ating pressure that is specified in “5.3 Specifications”.
For supply power, use a stabilized power supply with the ripple rate 1% max.
at supply voltage 24 V DC+/-10%.
The input signal used and other working conditions should be based on “5.3
Specifications”.
Zero (Point) & Span Adjustment:
This product is factory adjusted for the specified control pressure output in
relation to each input signal before shipment.
As a rule, no zero & span adjustment change is allowed.
If zero & span adjustments are required at customers end, contact our near-
est sales office or agent.
However, it should be understood that the zero and span adjusted product is
out of warranty.
Air filter
5m
Air dryer Oil mist filter
(Oil removing)
Pressure switch
Regulator
13
14
15
5.1 General outline of the system
MEVT - -T9GAR- - -3
1) The MEVT - -T9GAR- - -3 is a PARECT Electro-pneumatic regulator
mounted with a slave station to the EVT-T9GAR which can be connected to
the open field network CC-Link. There are some following characteristics.
(1) It helps to curtail wiring man-hours since only the CC-Link cable is re-
quired to connect it to a PLC.
(2) Installation can choose which the under or back fixation.
(3) The HOLD/CLEAR switch can be used to hold or clear the output signal
during a communication fault or analog output permission signal is turned
off.
(4) The communication speed can be set to : 156k, 625k, 2.5M, 5M, 10M bps.
2) What are CC-Link ?
CC-Link, which is an open field network for FA purposes, reduces wiring of
I/O devices such as sensors and valves and intelligent devices such as high
speed counters and inverters, and the system can be controlled without con-
sciousness of communications..
It has the following features.
(1) CC-Link is the fastest network in the industry (10Mbps), and it can meet
requirements of sensors requiring quick responses and communication of
large volume data.
(2) The remote control that handles bit data and data communications that
handle word data (analog) can be made simultaneously, while the com-
munication time is fast and stable.
(3) An n-to-n cyclic transmission between controllers can be made, making
distributed control easier.
NOTE) Be sure to read the Users Manual.
This manual mainly describes the MEVT - -T9GAR- - -3 and the
slave station EVT-T9GAR. Also, read the Users Manual for the mas-
ter station and other slave stations to be connected to this system.
In addition, regarding the PARECT Electro-pneumatic Regulator,
please read this manual and the above manuals carefully to fully un-
derstand the functions and performance of the product to be able to use
it properly.
If the customer has any question about the CC-Link, contact the following home
page.
CC-Link Association
Home page address :
http://www.cc-link.org
16
5.2 Structure of the System
This system chiefly consists of PLC body, Master unit, the PARECT Elec-
tro-pneumatic regulator MEVT - -T9GAR- - -3 and peripheral equip-
ment.
Combination of PLC and Master unit
PLC Maker Type of CPU Type of Master Unit
MITSUBISHI
ELECTRIC
CORPORATION
For A series AJ61BT11
For AnS series A1SJ61BT11
For QnA series AJ61QBT11
For QnAS series A1SJ61QBT11
For Q series QJ61BT11
For FX series FX2N-16CCL-M
Personal computer (PCI bus) A80BD-J61BT11
NEC ,Ltd Personal computer (PCI bus) FC-UG-X002
etc. Various The Master Unit adaptable CC-Link
Fundamental structure of system
Master station  Station controlling remote I/O stations, remote device stations,
and local stations.
Remote I/O station  Remote station that handles ON/OFF data only.
Remote device station  Remote station that handles ON/OFF data and numerical data.
Local station  Station that has its own CPU and can communicate with
the master station and other local stations.
Intelligent device station  Station informed by the transient transmission.
(including the local station)
PLC
Remote I/O
station
Remote device
station
Manifold solenoid valve
(Remote I/O station)
CC
-
Link system
PLC
Local station
Master
station
Electro
-
pneumatic Regulator MEVT
(Remote device station)
17
5.3 Specifications
1) PARECT Electro-pneumatic Regulator (Individual)
1
Model
Item EVT100 EVT500
Media Cleaned air (equivalent to ISO 1 3 2)
Max. working pressure 200kPa 0.7MPa
Min. working pressure Control pressure Max. control pressure 0.1
Proof pressure Inlet side 300kPa 1.05 MPa
Outlet side 150kPa 0.75MPa
Pressure control range 0 to 100kPa 0 to 0.5MPa
Power supply voltage DC24V 10% (Stabilized power supply with a ripple rate of 1% or less)
Consumption current 0.1A or lower
Insulation resistance 100M (DC500V megger) or more
Withstand voltage AC 1500V 1 minute
Hysteresis
2, 3
0.4% F.S. or less
Linearity
2, 3
0.5% F.S. or less
Resolution
2, 3
0.1% F.S. or less
Repeatability
2, 3
0.3% F.S. or less
Temperature
characteristic
Zero point fluctuation 0.15% F.S. / or less
Span fluctuation 0.07% F.S. / or less
Max. flow rate (ANR)
4
2L / min 6L / min
Step response
5, 6
No load 0.1s or less
15cm
3
load 0.5s or less
Ambient temperature 5 to 50
Fluid temperature 5 to 50
Lubrication Nil
Indicator
7
Green/Red LED
Installation position Free
Working environment No corrosive gas
Dimensions W14 D75 H75
Mass (body) 80g
1 : The above specifications are valid when the product is powered by 24 0.15VDC at normal temperature.
2 : Accuracy of serial transmission department is not included.
3 : These specifications are valid at a working pressure which is “1.1 times the maximum control pressure”
(EVT100 : 110kPa, EVT500 : 0.55MPa) and control pressure is from 10 to 100%. It is also assumed that the sec-
ondary side circuit constitutes a closed circuit. If the product is used for such purposes as blowing, for example, a
pressure fluctuation may occur.
4 : Working pressure : Maximum operating pressure, Control pressure : Maximum control pressure
5 : Working pressure : Maximum working pressure, Step rate : 50% F.S. 100% F.S.
50% F.S. 60% F.S.
50% F.S. 40% F.S.
6 : Serial transmission delay is not included.
7 : Indicator is for a rough standard. Accuracy is not guaranteed.
2) PARECT Electro-pneumatic Regulator (Manifold specifications)
Item Specifications
Manifold type Block manifold
Installation type DIN rail mount type
Air supply and exhaust Concentrated supply and exhaust
Max. manifold number 12
8, 9
Port size Output port (A) 4 6 Push-in joint
Input port (P) Exhaust port (R) 4 6 Push-in joint
8 : Slave station is possible installation to maximum 3 units to one manifold.
9 : PARECT Electro-pneumatic regulator maximum 4 units to one slave station.
18
3) Slave station specification
Item Specifications
Power supply voltage (Slave side) DC24V 10% (Stabilized power supply with a ripple rate of 1% or less)
Consumption current (Slave side) 80mA or lower (Except for load current)
Ambient temperature 5 to 50
Ambient humidity 30 to 85%RH (No dew fall)
Working environment No corrosive gas
Object of communication CC-Link Ver1.10 conformance
Transmission speed 156k/625k/2.5M/5M/10M bps (Selectable by switch)
Max. number of Input / Output (AD/DA) 4 / 4
DA
output
Pressure set ting data 12 bit
Accuracy 1%F.S. or less (Accuracy of EVT is not included.)
AD
input
Pressure monitoring data 12 bit
Accuracy 6%F.S. or less (Accuracy of EVT’s monitoring voltage is included.)
Fuse Slave power supply 24V 2A
No. of monopolized stations 1 station (Remote device station)
19
4) Profile
Remote register signal list
EVT-T9GAR Master Master EVT-T9GAR
Remote Input
(RX) Name Remote Output
(RY) Name
RXn0 CH1 A/D conversion completion flag RYn0 CH1 Analog output permission signal
RXn1 CH2 A/D conversion completion flag RYn1 CH2 Analog output permission signal
RXn2 CH3 A/D conversion completion flag RYn2 CH3 Analog output permission signal
RXn3 CH4 A/D conversion completion flag RYn3 CH4 Analog output permission signal
RXn4 Reserve RYn4 Not used
RXn5 Reserve RYn5 Not used
RXn6 Reserve RYn6 Not used
RXn7 Reserve RYn7 Not used
RXn8 Not used RYn8 Not used
RXn9 Not used RYn9 Not used
RXnA Not used RYnA Not used
RXnB Not used RYnB Not used
RXnC Not used RYnC Not used
RXnD Not used RYnD Not used
RXnE Not used RYnE Not used
RXnF Not used RYnF Not used
RX(n+1) 0 Reserve RY(n+1) 0 Reserve
RX(n+1) 1 Reserve RY(n+1) 1 Reserve
RX(n+1) 2 Reserve RY(n+1) 2 Reserve
RX(n+1) 3 Reserve RY(n+1) 3 Reserve
RX(n+1) 4 Reserve RY(n+1) 4 Reserve
RX(n+1) 5 Reserve RY(n+1) 5 Reserve
RX(n+1) 6 Reserve RY(n+1) 6 Reserve
RX(n+1) 7 Reserve RY(n+1) 7 Reserve
RX(n+1) 8 Not used RY(n+1) 8 Not used
RX(n+1) 9 Not used RY(n+1) 9 Not used
RX(n+1) A Not used RY(n+1) A Not used
RX(n+1) B Remote READY RY(n+1) B Vacant
RX(n+1) C Not used RY(n+1) C Not used
RX(n+1) D Not used RY(n+1) D Not used
RX(n+1) E (Reserve QnA) RY(n+1) E (Reserve QnA)
RX(n+1) F (Reserve QnA) RY(n+1) F (Reserve QnA)
Address given to the master unit according to the station number setting
Details of remote I/O signals
Device No. Signal name Description
RXn0 3 A/D conversion com-
pletion flag
The signal is turned on upon completion of first A/D conversion after power-on.
Once the signal is turned, it is not turned off (during correct communication).
Conversion is made in four channels without relations to the number of con-
nected load units (EVT). After the signal is turned on, save the digital output
value (monitored pressure data).
RX(n+1) B Remote ready
The signal is turned on after power-on. Once the signal is turned on, it is not
turned off (during correct communication). The signal is used to interlock in the
reading/writing cycle of the master unit.
RYn0 3 Analog output per-
mission signal
Analog value output permission signal. The analog value (output voltage added
to the load (EVT)) is issued after this signal is turned on. The analog output is
not output if this signal is turned off.
The state of the load (EVT) follows the setting of the output selection switch of
the slave station in the output prohibition state.
- HOLD: The output data sent to the EVT immediately before the output is
prohibited is held.
- CLEAR: The output data sent to the EVT is reset to "0."
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47