ADSPOT

American Dynamics ADSPOT Installation guide

  • Hello! I am an AI chatbot trained to assist you with the American Dynamics ADSPOT Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SINGLE-POSITION OUTDOOR TRANSFORMER INSTALLATION GUIDE (8000-2573-29, REV. A)
1 of 4
ADSPOT Single-Position
Outdoor Transformer
Installation Guide
WARNING! This device contains a piece
of cardboard over the transformer to
protect it during shipping. Remove and
discard the cardboard before installing
this device.
IMPORTANT: Read Regulatory Requirements and
other declarations on page 4.
About the Product
This weather-tight box (Figure 1) contains a Class
2 limited power source providing power to the
SpeedDome Ultra and SpeedDome Optima
outdoor camera housings.
Note: Because customer requirements dictate the
placement of components, your Sales representa-
tive will supply this information separately.
Figure 1. Transformer and Box
N
© Sensormatic 2003
Important Safeguards
A 15A, 2-pole, ganged disconnect device, which
also provides short circuit and overload protection,
and has a minimum 3mm open circuit clearance, in
accordance with the National Electrical Code,
Canadian Electrical Code and applicable local
codes must be installed at a location readily
accessible to the equipment.
(Ein 15A, 2-poliges, gekoppeltes Ausschaltgerät,
welches auch über einen Kurzschluß- sowie
Überbelastungsschutz verfügt, und einen minimum
3mm offenen Schaltabstand aufweist, nach
Übereinstimmung mit den Nationalen Elektrischen
Regelungen und Kanadisch Elektrischen
Regelungen sowie lokalen Regeln, muß an einem
Standort installiert werden, welcher einfachen
Zugang zum Gerät erlaubt.)
Outside elements. To keep outside elements from
entering the box, always mount it vertically with
cables exiting to the side or down.
Wire routing. Ensure wires from the secondary
and primary sides of the transformer do not cross
paths within the box.
Adding access holes to the enclosure. The box
meets the IP66 and NEMA 4 standards for
weatherproofing. To maintain this rating, do not drill
into the enclosure. Use outdoor rated conduit to
maintain the IP66 NEMA 4 rating.
See following pages for additional safeguards.
Transformer Label
Orange
Terminal Block
Knockouts
Mounting / Cover
Screw Hole
Fuse
Terminals
Ground
Terminal
!
SINGLE-POSITION OUTDOOR TRANSFORMER INSTALLATION GUIDE (8000-2573-29, REV. A)
2 of 4
Installation
The box can be mounted either indoors or outdoors
to any suitable vertical flat surface.
1. Remove the cover from the box.
2. Discard the cardboard covering the
transformer.
3. Using the box as a template, mark locations for
four mounting screws.
4. Drill holes. If in concrete, insert anchors.
5. Place the box in its mounting position. Then
insert a 1 inch #8 mounting screw (not
supplied) into each hole in the four corners of
the box and tighten to secure (Figure 3).
6. Run conduit and ac cable to the box and clamp
the conduit in place using fittings suitable for
outdoor use.
7. Connect the ac line to Euro-style input
terminals 1 and 4 on the transformer using
2.5mm
2
–1.5mm
2
(12–14 AWG) wire rated at
75°C minimum, and jumper the primary taps of
the transformer according to the input voltage
(Figure 2).
Note: The unit is built for 240Vac (jumper
across pins 2–3). For 120Vac, use the jumper
on the primary side and the jumper in the
install kit and place one jumper across pins
1–3 and one jumper across pins 2–4 as shown
below.
Figure 2. Transformer Wiring
24V
12V
0V
GND
120V
0V
120V
0V
1
2
3
4
Transformer Primary Jumper Settings
120Vac 1–3, 2–4
240Vac 2–3
8. Connect the low voltage power cable from the
camera dome to the secondary side of the
transformer.
WARNING! Do not run low voltage
cables adjacent to or in the same
conduit as line voltage mains power.
The length of this cable depends on the ac line
voltage. See the following table for cable
lengths based on worst-case low line voltages.
Worst-Case
Line
Voltages
.75mm
2
(18AWG)
1.25mm
2
(16AWG)
1.5mm
2
(14AWG)
90 Vac 30m (100') 50m (160') 80m (260')
102 Vac 60m (200') 100m (320') 160m (520')
180 Vac 30m (100') 50m (160') 80m (260')
204 Vac 60m (200') 100m (320') 160m (520')
Figure 3. Installing the outdoor dome power
source
Transformer
GND
N / L2 (Neutral)
L1 (Line)
Orange Connector
Gray
Connector
24Vac with
Center Tap
Ground
!
Knockout diameters, side of box:
15.5mm (.61in.) and 21mm (.83in.)
Knockout diameters, end of box:
23mm (.91in.) and 29mm (1.14in.)
SINGLE-POSITION OUTDOOR TRANSFORMER INSTALLATION GUIDE (8000-2573-29, REV. A)
3 of 4
Changing the Fuse
The outdoor dome power source has two fuses
(P/N 5111-0017-21). To reduce the risk of fire,
replace fuses only with the same type and rating
(3.15A type, IEC127, sheet III).
Wiring Diagram
L1 (Line)
N / L2 (Neutral)
GND
Blk
Wht
24V
12V
0V
GND
120V
0V
120V
0V
Transformer
Grn
Orange Connector
Gray
Connector
24Vac with
Center Tap
Ground
4
2
3
1
Class 2
24Vac
Connect the ac line
using 2.5mm -1.5mm
(12-14 AWG) wire rated
at 75°C minimum.
22
SINGLE-POSITION OUTDOOR TRANSFORMER INSTALLATION GUIDE (8000-2573-29, REV. A)
4 of 4
Specifications
Note: Transformer primary jumpers are field
changeable to support either 120Vac or 240Vac.
Electrical
Power source:.................... 120/240Vac @
50-60Hz
Input current:...................... 1.0A/0.5A
Output: ............................... 24Vac (29Voc),
2.5A max.
Listed Class 2
Certified Limited Power
Source
Mechanical
Environment....................... Indoor / Outdoor
Wall mounting options ....... Concrete, wood, sheet
rock
Dimensions (H x W x D) .... 175 x 125 x75mm
(6.9 x 4.9 x 3 inches)
Mounting area (H x W)....... 281 x 200mm
(11.1 x 7.9 inches)
Weight................................ 1.9kg (4.2 lbs)
Enclosure material ............. Impact resistant poly-
carbonate, non-metallic
Flammability rating...... UL 94-5V
Color .................................. Light gray
Cover fasteners ................. 4 captive screws
Cable access knockouts.... Eight 21 or 15.5mm
(0.83 or 0.61 inches);
Four 29 or 23mm
(1.14 or 0.91 inches)
Environmental
Weatherproof standard ...... NEMA 4 / IP66
Operating temperature: ..... –40°C to 50°C
(–40°F to 122°F)
Storage temperature:......... –40°C to 50°C
(–40°F to 122°F)
Relative Humidity:.............. 0 to 95% non-
condensing
Declarations
Regulatory Compliance
Reg ID ................................SV JBOX2
Safety .................................UL 60950
CSA C22.2 No. 60950
EN 60950
IEC 60950
FCC COMPLIANCE: This equipment complies with Part 15
of the FCC rules for intentional radiators and Class A digital
devices when installed and used in accordance with the
instruction manual. Following these rules provides reasonable
protection against harmful interference from equipment
operated in a commercial area. This equipment should not be
installed in a residential area as it can radiate radio frequency
energy that could interfere with radio communications, a
situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment
changes or modifications not expressly approved by
Sensormatic Electronics Corporation, the party responsible for
FCC compliance, could void the user's authority to operate the
equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics
Corporation makes no representation or warranty with respect
to the contents hereof and specifically disclaims any implied
warranties of merchantability or fitness for any particular
purpose. Further, Sensormatic Electronics Corporation
reserves the right to revise this publication and make changes
from time to time in the content hereof without obligation of
Sensormatic Electronics Corporation to notify any person of
such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department
of Defense, all documentation and manuals were developed at
private expense and no part of it was developed using
Government Funds. The restrictions governing the use and
disclosure of technical data marked with this legend are set
forth in the definition of “limited rights” in paragraph (a) (15)
of the clause of DFARS 252.227.7013. Unpublished - rights
reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: American Dynamics, Sensormatic,
and the Sensormatic logo are trademarks or registered
trademarks of Sensormatic Electronics Corporation. Other
product names mentioned herein may be trademarks or
registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
MDR 1/03
/