Xtreme SNMP-3PEX User manual

Type
User manual
Web/SNMP Cards
SNMP-1PMINI, SNMP-1PIN, SNMP-R90, SNMP-USB, SNMP-3PEX, SNMP-2P3 models
User & Installaon Manual
www.xpcc.com | © 2015 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 12/20/18)
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 2
UPS Management
Table of Contents
Introducon.................................................................................................4
Features...........................................................................................................................................4
Applicaons.....................................................................................................................................4
NetAgent Models............................................................................................................................6
NetAgent UPS Installaon..........................................................................10
NetAgent, UPS and Network Connecon....................................................11
Install the NetAgent with UPS and Network..................................................................................11
Using Nelity Setup IP. Update Firmware....................................................13
Install Nelity.................................................................................................................................13
Using Nelity..................................................................................................................................13
UPS Web Management by NetAgent..........................................................17
Introducon...................................................................................................................................17
NetAgent UPS Web Interface.........................................................................................................17
Telnet (Remote Conguraon)....................................................................48
Introducon...................................................................................................................................48
Telnet Conguraon......................................................................................................................48
Telnet Conguraon......................................................................................................................50
ClientMate - Windows Shutdown Ulity.....................................................51
Install ClientMate..........................................................................................................................51
Using ClientMate...........................................................................................................................51
SNMPView – Windows Based UPS Management System............................57
Introducon...................................................................................................................................57
System Requirements....................................................................................................................58
Install SNMPView..........................................................................................................................58
Using SNMPView...........................................................................................................................58
SNMPView Buons.......................................................................................................................59
Appendix A: Update the Firmware of NetAgent UPS...................................75
Appendix B: 3 Ports NetAgent II with SMS Modem.....................................78
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 3
UPS Management
Appendix C: SMS Server with SMS Modem.................................................81
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 4
UPS Management
Introducon
Features
NetAgent is a new generaon SNMP (Simple Network Management Protocol) monitoring product. Not only
can you remotely control the UPS and get the current status of it, the SNMP-3PEX also can provide other func-
ons, such as connecng via Modem or GSM Modem to make monitoring possible when there is no permanent
internet connecon and send SMS nocaon . The SNMP-3PEX can also bee used to connect to SNMP-EMP, to
get the temperature, humidity and water condions. Smoke detector, gas detector, door and window detector
opons are also available.
This product is compable with Contact Closure and RS232 interface UPS. The communicaon protocol includes
the Contact Closure, RS232 [MegaTec], RS232 [Phoenixtec], SEC 2400, SEC 9600, Three Phase, Powerware, Smart
APC, EMERSON. User could also provide their own protocol to build in. NetAgent provides a simple and easy
installaon procedure. The CD included with the NetAgent cards oer several soware programs to allow the
user to congure IP address; central monitoring and mul client shutdown on dierent operang systems. Other
advance conguraons can be accomplished via a Web browser.
Features:
Provide SNMP MIB to monitor & control UPS
Auto-sense 10M/100M Fast Ethernet
Manage and congure via Telnet, Web Browser or NMS
Support TCP/IP, UDP, SNMP, Telnet, SNTP, PPP, HTTP, SMTP Protocol
Providing easy setup and upgrade tools via MS-Windows, just a few seconds to nish IP seng, about
1.5 minutes to upgrade rmware.
Send SNMP TRAP; E-mail and SMS for events nocaon.
Auto email daily UPS history report
Client shutdown soware for computers le saving and graceful shut down.
SNMP-3PEX: Environment Measurement (Oponal Kits), External modem dial in/out via PPP protocol or
GSM/GPRS Modem
Applicaons
NetAgent Connects your UPS to the Network
When the UPS is equipped with a NetAgent Web/SNMP card, the system manager can monitor and check the
state of each and every UPS via a Web browser. The manager can monitor and control the UPS by simply brows-
ing the IP address of the NetAgent Web/SNMP card in to the UPS. When an abnormal power condion happens,
the NetAgent can also send trap informaon or an email to the system manager to take proper acon.
NetAgent Provides Shutdown Ulies
When a computer on the network has the NetAgent ulity installed, it can locate all of the NetAgent Web/SNMP
cards on the network. When the registered UPS of this NetAgent is in AC failure condion or Baery Low condi-
on, the operang system can close all the les on the system, and perform a gracefully shutdown. This could
avoid system corrupon when the UPS baery runs low.
NetAgent for Surrounding Monitoring
SNMP-3PEX can be used to connect the environmental monitoring ulity, SNMP-EMP, to get the temperature/
humidity/smoke/re indicaons. This informaon can also be displayed on the NetAgent Web page. When an
abnormal condion happens, it can also be sent as a trap to the system manager.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 5
UPS Management
When do we need the NetAgent Web/SNMP Card?
1. When we need to remote monitor and control the UPS condions. For example, the system manager could
use the network to control all the UPS condions all over the country. When the shutdown ulity is installed,
the shutdown ulity could close all the les and shutdown the system when a abnormal power condion
happened.
2. When we need to monitor environmental condions of the machine room, warehouse, oce, …etc. For ex-
ample, the system manager could know the temperature, humidity, smoke and water condion by using the
SNMP-3PEX and SNMP-EMP. The system manager could connuously monitor these environmental condi-
ons over a Web browser.
NetAgent Connecon Soware
SNMP-3PEX Diagram
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 6
UPS Management
NetAgent Models
P/N Package Contents Internal/External
SNMP-1PIN
1. 1 Port Internal card
2. NetAgent Ulity CD
3. User Manual
Internal
SNMP-3PEX
1. 3 Port External Agent
2. NetAgent Ulity CD
3. User Manual
4. M2501 Cable (for Contact Closure UPS)
5. M2502 or M2505 Cable (for RS232 UPS)
6. M2506 Cable (for Modem)
7. 9V DC adapter
External
SNMP-1PMINI
1. Internal NetAgent Mini
2. NetAgent Ulity CD
3. User Manual
Internal
SNMP-R90
1. Internal NetAgent Mini
2. NetAgent Ulity CD
3. User Manual
4. 5.3V DC adapter
External
SNMP-USB
1. Internal NetAgent Mini with LCD Display
2. NetAgent Ulity CD
3. User Manual
4. 5.3V DC adapter
External
Pictures of NetAgent Web/SNMP Cads
SNMP-1PIN
SNMP-3PEX
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 7
UPS Management
SNMP-1PMINI
SNMP-R90
SNMP-USB
NetAgent Package Contents
NetAgent Ulity CD, includes:
» Nelity: Congure NetAgent IP address, update rmware
» ClientMate:Windows, Linux, FreeBSD shutdown ulity.
» SNMPView: Windows plaorm mulple NetAgent UPS management soware.
» SMS Server: SMS Nocaon
» UPS MIB: MIB le for the Network Management System
» Time Server:Time adjustment ulity
» And NetAgent Installaon/Users Manual
M2502 (or M2505) Cable: For external NetAgent II connecon to RS-232 UPS.
M2506 Cable: For connecon SNMP-3PEX and Modem.
9V DC Adapter: For SNMP-3PEX
5.3V DC Adapter: For SNMP-R90 or SNMP-USB
NetAgent Outlook
SNMP-1PIN
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 8
UPS Management
SNMP-3PEX
LED Table
Yellow Red Green Status
Solid O Solid O Solid ON Power ON
Flashing Solid ON Solid ON System inial
Solid ON Solid O Solid ON Normal operaon
Solid ON Flashing Solid ON No connecon to UPS
Flashing Flashing Solid ON
Wring data to ash
memory
Green light: Power state
Red light: Connecon state with UPS
SNMP-1PMINI
SNMP-R90
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 9
UPS Management
SNMP-USB
LED Table
Yellow Red Green Status
Solid O Solid O Solid ON Power ON
Flashing Solid ON Solid ON System inial
Solid ON Solid O Solid ON Normal operaon
Solid ON Flashing Solid ON No connecon to UPS
Flashing Flashing Solid ON Wring data to ash memory
Green light: Power state
Red light: Connecon state with UPS
Light signal applicaon - Status LED
Light color Signal denion Condion descripon
Green Power state On: Normal power
Red Connecon state with UPS Flash: no connecon with UPS
Orange Correspondence state Light ashes when Netagent transmits command to UPS
Light signal applicaon - LAN Port LED
Light color Condion descripon
Green
On: Internet correspond speed is 100M
Flash: Data transming
Yellow
On: Internet correspond speed is 10M
Flash: Data transming
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 10
UPS Management
NetAgent UPS Installaon
Before using the NetAgent, the proper hardware and soware conguraon is necessary. Hardware installaon
connects the NetAgent and UPS and network. Soware conguraon includes the IP address. Firmware upgrade.
Or using the Browser or Telnet for conguraon.
You could also install the shutdown ulity – ClientMate to protect your Windows operang system. And also
could use the UPS management soware – SNMPView, to control and manage mulple UPS on the network.
NetAgent UPS installaon owchart
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 11
UPS Management
NetAgent, UPS and Network Connecon
NetAgent provides external and internal model for dierent UPS interface requirement. Please reference the fol-
lowing descripon for detailed informaon of UPS and network connecon.
Install the NetAgent with UPS and Network
For SNMP-1PMINI
Please make sure the connector direcon of the cable is correct before connecng to the NetAgent.
Connect the NetAgent module to LAN, using the UTP port.
SNMP-1PMINI Installaon
For SNMP-3PEX
Connect the NetAgent Adapter to LAN, using the appropriate UTP port.
Connect the specied serial cable (M2501/M2502/M2505) from NetAgent Adapter to the serial port of
UPS.
Plug supplied AC adapter to the wall socket, the other side connects with the NetAgent Adapter.
Turn on the UPS
SNMP-3PEX Installaon
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 12
UPS Management
For SNMP-1PIN
Insert the Net Agent Card into the slot of UPS.
Connect the Net Agent Card to LAN, using the appropriate UTP port.
SNMP-1PIN Installaon
For SNMP-R90 and SNMP-USB
Connect the NetAgent to LAN, using the UTP port.
Connect the cable from NetAgent to the serial port of UPS.
Plug the DC adapter to UPS outlet, the DC plug connects with NetAgent.
SNMP-USB Installaon
Warning: Please make sure the input Voltage and Frequency of the DC power adapter (NetAgent II – DC 9V /
NetAgent Mini – DC 6V or 5.3V) is correct before plugging it in.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 13
UPS Management
Using Nelity Setup IP. Update Firmware
Install Nelity
Insert NetAgent Ulity CD to the CD-ROM driver and execute Nelity.exe.
Aer complete installaon, there will be a ‘Nelity’ group in Windows ’Start’ ‘Program Group’.
Nelity Group
Click “Nelity” to iniate the Nelity and enter the mail window for conguraon.
Using Nelity
The main window of Nelity is below. The right side is to show you all of the NetAgent devices found on the LAN;
the le side is the funcon selecon menu.
Nelity Main Window
Launch Device
Click Launch Device or double click the NetAgent listed in the table to launch it. Enter the Account (Login Name)
and Password (Login Password) set earlier to login. If you did not congure the login yet, then just click Apply to
login.
Network Sengs
Choose the NetAgent from the right of the screen, then click “Congure”, which shows the following seng
page.
IP Address: Set IP address for Netagent UPS
When using for the rst me, please set IP address; subnet mask; and gateway. Aer seng, enter IP address
from Telnet or Browser to connect to NetAgents web page.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 14
UPS Management
Nelity Congure
When using DHCP or BOOTTP to set up IP address, then the IP address, Subnet Mask and Gateway would receive
their address directly from the network system.
Advanced: Advanced NetAgent UPS Seng
In order to ensure the secure management of the UPS, Nelity provides two security funcons:
Management Protocol
Netagent UPS provides HTTP/HTTPS (WEB) and Telnet to reference any related parameter seng for the man-
ager. Concerning security, the manager could build use openly or any advance port seng methods. Followings
are the descripon:
1. At advanced seng, two funcons were set as acvated by using port number 80 and 23 for Hp and
Telnet. As for Hps and SSH are 443 and 22.
2. Unselect means not using the funcon.
3. When set to the other port value, full IP Address must be entered in order to login to the website or
Telnet.
For example,
Set 81 as HTTP port number, then hp://192.168.0.177:81 must be typed at the web address to proceed
to Netagent UPS’s web page.
Set 23 as Telnet port number, then “192.168.0.177:24” must be typed at Telnet to proceed to the Telnet
screen of NetAgent UPS.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 15
UPS Management
Nelity Advanced
Nelity Password
Aer seng the password, any further command to NetAgent by Nelity soware requires the users password.
(NB. If you lose this password, Netagent UPS will never be able to complete any upgrade process.)
Nelity : Advanced seng of Netagent UPS
Firmware Upgrade
NetAgent oers a convenient rmware upgrade funcon. When you are going to upgrade rmware, click Down-
load Firmware from the NetAgent Setup menu, click “Browser” select new rmware le (*.bin) and press “Start”.
NetAgents Red LED and Yellow LED ashing alternave means the rmware is upgrading. Aer upgrade is com-
pleted, Net Agent will auto reboot. To upgrade mulple NetAgents simultaneously with the same rmware, hold
the “Shi” or Ctrl” key and choose the NetAgent device from Nelity list.
(Please visit to hp://www.megatec.com.tw for the latest rmware) If upgrading mulple units, select When
upgrade rmware to mulple NetAgent.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 16
UPS Management
Note: NetAgent provides a rmware protecon funcon. If uploading was interrupted and upgrade data is
incomplete, NetAgent will keep its default data to avoid complete data loss. In this case, just repeat “rmware
upload” upgrade.
Nelity : Update NetAgent UPS rmware
About - Nelity version examined
Nelity version examined
Refresh List - Search Lan’s Netagent UPS manually
Nelity can search for all of the available NetAgent on Lan automacally, or the user can search manually by
clicking on “Search NetAgent.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 17
UPS Management
UPS Web Management by NetAgent
Introducon
Aer nishing NetAgent installaon, including hardware installaon and IP seng, you are now able to monitor
and control the UPS by inpung NetAgent IP address in Browser.
Starng the Web Brower (Netscape or Internet Explore)
Enter the NetAgent IP Address (Which is seng on Nelity, e.g. 192.168.0.156).
Input NetAgent UPS IP address
On the rst screen, enter the current password. If no password has been set, just press [ENTER].
NetAgent UPS Login dialog
NetAgent UPS Web Interface
Enter NetAgent UPS Web page, there are 4 main selecons in the rst Web page:
Informaon
Conguraon
Log Informaon
Help
Enter the selecon item, the sub-menu items will be shown on the le side of the page. When using this NetA-
gent for the rst me, please enter the [Conguraon] menu item to set all the conguraon items. Then the
UPS status will be accurately shown on other pages.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 18
UPS Management
NetAgent UPS - single port
NetAgent UPS - 3 ports
NetAgent 9
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 19
UPS Management
Informaon
Sub-Menu:
System Status
Basic Informaon
Current Status
Remote Control
Meter/Chart
Modem Status
Environment Sensors-NetFeeler II
Note: The opons available on this menu depend on the NetAgent model. (e.g. “NetFeeler II” will not be display
for one port.)
System Status
This page is to show NetAgent system informaon and Network sengs. Values shown here are either provided
by NetAgent itself or they are user sengs from the Conguraon pages.
System Informaon
This secon is to show NetAgent system informaon. Values in Hardware Version/Firmware Version/
Serial Number/System Time, are provided by NetAgent itself. Other values are user sengs from the
Conguraon pages.
Network Status
This secon is to show NetAgent Network sengs. The MAC address is provided by NetAgent. All other
values in this secon are user sengs from the Conguraon pages.
System Status
Basic Informaon
This page is to show UPS basic informaon. Values here are either provided by the UPS or they are user sengs
from the Conguraon pages.
UPS Informaon
Informaon about UPS Manufacturer/UPS Firmware Version/UPS Model are provided by the UPS.
Xtreme Power Conversion Corporaon
Web/SNMP Cards
Page 20
UPS Management
Baery Informaon
Values here are user sengs from the Conguraon pages.
Rang Informaon
Values here are provided by the UPS.
Basic Informaon
Current Status
This page is to show the UPS current status. Users can choose an interval from the drop-down box to refresh the
status readings.
UPS Status
This secon is to show the UPS power status. The abnormal status will be displayed in red when there is
a power event.
Input Status
This secon is to show the UPS input status, including AC Status/Input Voltage/Input Frequency. Values
here will be shown in red when an abnormal status condion occurs.
Output Status
This secon is to show the UPS output status, including Output Voltage/Output Status/UPS Loading.
Values here will be shown in red when an abnormal status condion occurs.
Baery Status
This secon is to show the UPS Baery Status, including Temperature/Baery Status/Baery Capacity/
Baery Voltage/Time on Baery..etc. Values here will be shown in red when an abnormal status condi-
on occurs.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73