TEMP-LED INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
FIXTURE MOUNTING
CAUTION: SUITABLE FOR WET LOCATION
1. Clip xture to a secure mounting point using Carabiner
(supplied).
WARNING: Fixture will get hot during operation, wait until it
cools before handling
IMPORTANT
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING FIXTURE.
WARNING: When using outdoor use portable luminaires, basic safety precautions, including the following, should always be
followed to reduce risk of re, electric shock and personal injury:
• Use only three-wire outdoor extension cords that have three-prong grounding plugs and grounding receptacles that accept
the appliance’s plug
• Ground Fault Circuit Interrupter (GFCI) protection is to be provided on the circuit(s) or outlet(s) to be used for the wet location
portable luminaire. receptacles are available having built-in GFCI protection and are able to be used for this measure of safety.
• Use only with extension cord for outdoor use, such as an extension cord of cord type SEW, SEOW, SEOOW, SOW, SOOW, STW,
STOW, STOOW, SJEW, SJEOW, SJEOOW, SJW, SJOW, SJOOW, SJTW, SJTOW or SJTOOW.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. Make certain power is
OFF before installing or maintaining xture. No user serviceable parts inside.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Cord
Carabiner
Lens
Guard
Fixture
Plug
DAISY CHAIN CONNECTION (OPTIONAL)
CAUTION: THE MAX WATTAGE FOR THE CASCADING UNITS IS
1016W/120VAC
Cascading models: The power cord plugs into previous unit, female
cord/plug receptacle (provided). To determine MAX power per
cascading model see following:
1. Connect the rst Fixture to power using the Plug
2. Connect the Plug from second Fixture into Convenience
Receptacle of the previous.
3. Repeat step 2 until all xtures are connected
4. If Convenience Receptacle is not used the female plug shall be
closed o with the attached Receptacle Cover. See Fig.A above.
Note: Do not remove or cut-o the Receptacle Cover
5. Total power equals the sum of the rst xture wattage plus all
xture wattages cascaded o the rst one.
Recepticle
Recepticle
Guard
Plug
Fixture
Fig. A
Fig. B
PLUG CONNECTION
1. 120VAC xtures with Plug, insert into outlet.
2. Connect the unit plug (provided) to a NEMA approved
receptacle (not provided)
Recepticle Cover