Admiral ZV4-1 Operating instructions

Type
Operating instructions
Admiral·
GAS FIRED MULTIPOINT WATER-HEATER
MODEL ZV4-1
[~
Your Admiral Gas Fired Water Heater is an efficient economic luxury appliance that provides an instantaneous hot
water supply to several water outlets, in your home, without the need for storage tanks.
The pilot flame remains alight during operation and is initially lit by a piezoelectric igniter which does not require
electricity or batteries. The main gas burner is ignited automatically whenever a hot water tap is opened and it is
turned off when the water tap is closed.
NOTE: Gas Safety (Installation and Use) Regulations 1984: It is the Law that all gas applicances are installed
by competant persons in accordance with the above regulations. It is in your own interest and that of
safety to ensure compliance with the law. Failure to install appliances correctly could lead to
prosecution.
A. LIGHTING THE PILOT FLAME FIG.3
1. Before ignition make sure that the gas service cock is turned on. The gas service cock is fitted to the
gas inlet located beneath the appliance in the central position (Fig. 1).
The gas supply is turned on when the slot of the lower screw is vertical (Fig.
2),
Vertical slot in lower screw
indicates 'GAS ON'
I(~·(nl
@
/
Water outlet
"'-
Water inlet
2. Slide the control knob (15) to the 'gas on' position (smaller symbol
ti'T ).
3. Press home the button (14) on the control knob as far as it will go and hold it in this position, then with
your right hand, press in the piezoelectric igniter (11) (symbol " ) until a click is heard, a spark will
then be generated. The gas flowing through the pilot flame burner (17) will be ignited by the piezo
spark.
The lighting of the pilot flame can be checked through the pilot flame monitoring window. If the
ignition has not been successful, press the piezoelectric igniter again.
4. After lighting the pilot flame, keep the push button (14) depressed for a period of approx. 15 secs.
When the button is released the pilot flame should remain alight. If it-does not, slide knob (15) to
OFF. - wait 3 minutes and repeat the sequence.
When the pilot flame is alight the main burner will be ignited automatically whenever any hot water tap is
opened.
7 1
KEY TO SYMBOLS
'GAS OFF'
I1f,
'GAS ON - LOW/PILOT IGNITION'
D
'GAS ON - HIGH'
" PIEZOELECTRIC IGNITER BUTTON
'WATER FLOWITEMPERATURE - HOT'
6
'WATER FLOW/TEMPERATURE - WARM'
Using the temperature selector (9) and the control knob (15) the water temperature can be adjusted over a
wide range to suit individual needs.
1.
When the control knob is moved fully to the Right (symbol
D )
the water heater operates at
maximum gas rate.
Then by means of the temperature selector (9) the hot water temperature can be adjusted between
approx. 35 to 65°C. Turning the selector in a clockwise direction increases the temperature and
reduces the quantity and when turned anti-clockwise the water temperature is reduced and the
quantity increased.
2. If the control knob (15) is positioned to the left at symbol
11',
the water heater operates at half gas
rate. Using the temperature selector (9) the temperature of the water can be adjusted within a warm
water range of approx. 22 to 35°C. The gas rate of the water heater can be adjusted to any position
between the symbols.
If the water heater is not required for short periods the pilot should be left alight. For longer periods turn
off the water heater.
7121
To turn off, slide the control knob (15) as far as it will go to the left to symbol . This cuts off the gas
supply and extingl.!ishes the pilot flame. Check through the monitoring window that the pilot flame has gone
out.
Wait 3 minutes before attempting to relight the pilot flame if the gas supply to the water heater has been cut-
off, or if the control has been set to off. or if the pilot flame has blown out.
As the water heater is directly connected with the outside atmosphere attention should be paid to the danger
of freezing.
(1)
In frosty weather the risk of freezing can be avoided if the pilot flame is kept alight.
(2)
In the case of severe frost or when the house isunoccupied for an extened period the water should be
!
drained from the appliance. Consult your local Service Engineer.
It is recommended that the cover be wiped regularly with a cloth dampened with hot soapy water and then
polished with a dry cloth. Do not use abrasive powders or strong detergent for cleaning as they will scratch or
damage the painted surface.
To ensure a long life and trouble free operation the water heater should be serviced on a yearly basis by a
competant person. Your local Gas supplier or a recognised CORGI installer will advise you on a regular
.servicing plan.
I. SAFETY
1. To allow for safety and servicing your installer will have provided clearance space on all sides of the
appliance. Do not use this space for storage or hang any article on the appliance.
2. If the appliance has been installed in a cupboard or separate compartment do not use for storage or
obstruct any purpose provided ventilation.
3. If a gas leak or fault is suspected, turn off the appliance and consult your installer or Service Engineer.