QFX3000-M QFabric System

Juniper QFX3000-M QFabric System, QFX3000-G QFabric System, QFX3100 Quick start guide

  • Hello! I am an AI chatbot trained to assist you with the Juniper QFX3000-M QFabric System Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Quick Start Guide
QFX3100
IN THIS GUIDE
Step 1: Begin | 1
Step 2: Up and Running | 5
Step 3: Keep Going | 6
Step 1: Begin
IN THIS SECTION
Mount the QFX3100 | 2
Connect Power to the QFX3100 | 3
Connect the QFabric System Control Plane and Data Plane | 4
To install and configure a Juniper Networks QFX3100 Director device, you need:
One pair of adjustable rear mounting brackets (provided)
Screws to attach the mounting brackets to the chassis (provided)
Phillips (+) screwdriver, number 2, to remove and tighten screws
12 screws to secure the chassis and mounting brackets to the rack (not provided)
Screwdriver appropriate for your rack mounting screws (not provided)
Two power cords with plugs appropriate for your geographical location (provided)
Mount the QFX3100
These instructions describe mounting the device in a four-post 19-in. rack or cabinet.
1. Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the
building structure.
NOTE: If you are mounting multiple units in the rack, mount the heaviest unit at the bottom of the rack, and
mount the others from bottom to top in order of decreasing weight.
2. Measure the distance between the front and rear rack rails. Using this measurement, attach the adjustable rear mounting
brackets to both sides of the chassis using the provided screws. These mounting brackets support the rear of the
chassis and must be installed.
g050061
3. Flip open the hinged rack-mounting plates at the end of the brackets before positioning the device between the rack
rails.
NOTE: The device weighs approximately 41.2 lb (18.7 kg). Installing the QFX3100 Director device in a rack
or cabinet requires one person to lift it and a second person to secure it to the rack.
4. Have one person grasp both sides of the device, lift it, and position it in the rack, aligning the front bracket holes with
the holes in the rack.
2
5. Have a second person install a mounting screw—and cage nut and washer if your rack requires them—in each of the
four bracket holes to secure the device to the front rack rails.
6. While still supporting the chassis, have the second person install a mounting screw—and cage nut and washer if your
rack requires them—in each of the three bracket holes on the adjustable rear mounting brackets to secure the device
to the rear rack rails.
Connect Power to the QFX3100
1. Insert the coupler end of the power cord into the AC power cord inlet on the AC power supply faceplate.
2. If the AC power source outlet has a power switch, set it to the OFF (O) position.
3. Insert the power cord plug into an AC power source outlet.
4. If the AC power source outlet has a power switch, set it to the ON (|) position.
5. Repeat Step 1 through Step 4 for the second AC power supply.
6. To power on the device, set the power switch on the back of the QFX3100 Director device to the ON (I) position. The
power switch is located next to the power supplies.
3
Connect the QFabric System Control Plane and Data Plane
The initial connection and configuration of your Juniper Networks QFX3000 QFabric System are beyond the scope of
this quick start. The following steps provide an overview of the tasks required to complete the setup process for your
QFabric system. The port connections are specific and cannot be described fully here. For a detailed description of the
port connections, see the deployment guide for your QFabric system at
https://www.juniper.net/documentation/en_US/junos/information-products/pathway-pages/qfx-series/qfabric-deployment.html.
g050068
USB
Management
Ethernet port
Console
port
Ports 1-4 Ports 5-8
1. Install a second QFX3100 Director device. Together the two Director devices form a Director group. The second
Director device provides redundancy for the QFabric system control plane and management network.
2. Connect network module ports on the first QFX3100 Director device to the second Director device. See the QFabric
system control plane example in the deployment guide for your QFabric system at
https://www.juniper.net/documentation/en_US/junos/information-products/pathway-pages/qfx-series/qfabric-deployment.html.
3. Using the connection diagram in the deployment guide, connect network module ports on the QFX3100 Director
device to Juniper Networks control plane Ethernet switches. This connects the Director device to the control plane
for your QFabric system.
4. Connect your Interconnect devices and Node devices to the control plane Ethernet switches.
5. Connect the QSFP+ uplink ports on each Node device to the 40-Gigabit Ethernet QSFP+ ports on your Interconnect
devices. Connect the 10-Gigabit Ethernet or Fibre Channel ports on the Node devices to servers or storage devices.
These connections form the data plane for your QFabric system.
6. Connect your management network to the management Ethernet port on both Director devices.The management
Ethernet (MGMT) port is located on the left side of the front panel of the Director device.
4
Step 2: Up and Running
IN THIS SECTION
Set Parameter Values | 5
Perform the Initial Configuration | 5
Log In | 6
Set Parameter Values
After you power on the QFX Series device, you must perform the initial setup of the QFX3100 Director group.
Before you begin, set the following parameter values in the terminal emulator software on your laptop or PC:
Baud Rate—9600
Flow Control—None
Data—8
Parity—None
Stop Bits—1
DCD State—Disregard
Perform the Initial Configuration
To connect and configure the Director group from the console:
1. Connect the console port of one Director device in the group to a laptop or PC using the provided RJ-45 cable and
RJ-45 to DB-9 serial port adapter. The console (CONSOLE) port is located on the front panel of the Director device.
2. Insert the USB flash drive containing the range of reserved MAC addresses, software serial number, and platform type
information for your QFabric system into the USB port on the Director device.
NOTE: If the USB flash drive is not provided with your Director device, the initial setup script will prompt you for this
information, which is obtained through the License Management System at
https://www.juniper.net/documentation/en_US/release-independent/licensing/information-products/pathway-pages/licensing.html.
5
3. Log in as root. If the software booted before you connected to the console port, you might need to press the Enter
key for the prompt to appear.
NOTE: The login prompt is either dg0 login or dg1 login depending on the Director device to which you
connected your cable.
4. The Director group initial setup script prompts you to configure the QFabric system with the following information:
IP addresses and a default gateway IP address for your QFabric system default partition
IP addresses for your Director group device management ports
A root password for your Director group, and a root password for the QFabric components such as the Node devices,
Interconnect devices, and infrastructure
Log In
1. Once you connect your management network to the management Ethernet ports on your Director devices and you
run the initial setup script on your Director group, log out of your console connection to the Director group.
2. From a management station on your management network, log in to the QFabric system default partition (using the
IP addresses you specified in the Director group installation script). For detailed information about these procedures,
see the deployment guide for your QFabric system at
https://www.juniper.net/documentation/en_US/junos/information-products/pathway-pages/qfx-series/qfabric-deployment.html.
Step 3: Keep Going
IN THIS SECTION
Safety Warnings Summary | 7
Power Cable Warning (Japanese) | 7
Contacting Juniper Networks | 8
6
See the complete QFX3100 documentation at
https://www.juniper.net/documentation/en_US/release-independent/junos/topics/concept/qfxctrl-hardware-overview.html.
Safety Warnings Summary
This is a summary of safety warnings. For a complete list of warnings, including translations, see the QFX3100 documentation
at
https://www.juniper.net/documentation/en_US/release-independent/junos/topics/concept/qfxctrl-hardware-overview.html.
WARNING: Failure to observe these safety warnings can result in personal injury or death.
Permit only trained and qualified personnel to install or replace device components.
Perform only the procedures described here and in the QFX Series documentation. Other services must be performed
only by authorized service personnel.
Before installing the device, read the planning instructions in the QFX Series documentation to make sure that the site
meets power, environmental, and clearance requirements for the device.
Before connecting the device to a power source, read the installation instructions in the QFX3100 Director device
documentation.
z A fully loaded QFX3100 Director device weighs approximately 41.2 lb (18.73 kg). Manually installing the device in a
rack or cabinet requires one person to lift the device and a second person to install the mounting screws. To prevent
injury, keep your back straight and lift with your legs, not your back.
If the rack or cabinet has stabilizing devices, install them in the rack before mounting or servicing the device in the rack
or cabinet.
Before installing or after removing an electrical component, always place it component-side up on a flat antistatic mat
or in an antistatic bag.
Do not work on the device or connect or disconnect cables during electrical storms.
Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches.
Metal objects heat up when connected to power and ground and can cause serious burns or become welded to the
terminals.
Power Cable Warning (Japanese)
The attached power cable is only for this product. Do not use this cable for another product.
7
g040300
Contacting Juniper Networks
For technical support, see:
http://www.juniper.net/support/requesting-support.html
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in the
United States and other countries. All other trademarks, service marks, registered marks, or registered service marks are the
property of their respective owners. Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper
Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Copyright © 2020
Juniper Networks, Inc. All rights reserved. Rev. 01, June 2020.
8
/