H3C WA510H Installation guide

Category
Network switches
Type
Installation guide
H3C WA510H Access Point
Installation Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W101-20190527
Copyright © 2018-2019, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written
consent of New H3C Technologies Co., Ltd.
Trademarks
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this
document are the property of their respective owners.
Notice
The information in this document is subject to change without notice. All contents in this document, including
statements, information, and recommendations, are believed to be accurate, but they are presented without
warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions
contained herein.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage, use,
and disposal of this product must meet the applicable national laws and regulations.
Preface
This installation guide describes the installation procedure for the H3C WA510H Access Point.
This preface includes the following topics about the documentation:
Audience.
Conventions.
Documentation feedback.
Audience
This documentation is intended for:
Network planners.
Field technical support and servicing engineers.
Network administrators working with the WA510H.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Description
Boldface Bold
text represents commands and keywords that you enter literally as shown.
Italic
Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars,
from which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign
can be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Description
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the
New User
window opens; click
OK
.
>
Multi-level menus are separated by angle brackets. For example,
File
>
Create
>
Folder
.
Symbols
Convention Description
WARNING!
An alert that calls attention to important information that if not understood or followed
can result in personal injury.
CAUTION:
An alert that calls attention to important information that if not understood or followed
can result in data loss, data corruption, or damage to hardware or software.
IMPORTANT:
An alert that calls attention to essential information.
NOTE:
An alert that contains additional or supplementary information.
TIP:
An alert that provides helpful information.
Network topology icons
Convention Description
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that
supports Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access
controller engine on a unified wired-WLAN switch.
Represents an access point.
Represents a wireless terminator unit.
Represents a wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security
gateway, or load balancing device.
Represents a security module, such as a firewall, load balancing, NetStream, SSL
VPN, IPS, or ACG module.
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots,
and other information in the examples differ from what you have on your device.
T
T
T
T
Documentation feedback
You can e-mail your comments about product documentation to [email protected].
We appreciate your comments.
i
Contents
Preparing for installation ···································································· 1
Safety recommendations ············································································································· 1
Temperature and humidity requirements ························································································· 1
Accessories provided with the AP ·································································································· 1
Installation tools and equipment ···································································································· 2
Installing the AP ··············································································· 3
Check before installation ············································································································· 3
Installing the AP ························································································································ 3
Attaching the mounting bracket to an electrical outlet box ···························································· 3
Connecting cables ··············································································································· 4
Installing the AP ·················································································································· 5
Connecting the AP to the power supply ·························································································· 6
Check before power-on ········································································································ 6
Connecting the PoE power supply ·························································································· 6
Connecting the local power supply ·························································································· 7
PoE injector power supply ····································································································· 8
Check after power-on ··········································································································· 8
Connecting the AP to the network ·································································································· 8
Appendix A Technical specifications ··················································· 10
Appendix B LEDs and ports ······························································ 11
LEDs ····································································································································· 11
Ports ····································································································································· 12
1
Preparing for installation
Safety recommendations
WARNING!
Only qualified personnel can install and remove the AP and its accessories. You must read all safety
instructions supplied with the AP before installation and operation.
Take adequate safety measures to avoid injury and AP damage.
Place the AP in a dry and flat location and take anti-slip measures.
Keep the AP clean and dust-free.
Do not place the AP in a moist area and avoid any liquid intrusion.
Keep the AP and installation tools away from walkways.
Temperature and humidity requirements
Item Specification
Operating temperature
0°C to +40°C (32°F to 104°F)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
Operating humidity (noncondensing)
5% to 95% RH
Accessories provided with the AP
× 2
× 1
M3.5 × 25 screw M2.9 × 4 security screw Mounting bracket
2
Installation tools and equipment
When installing the AP, you might need the following tools. Prepare these tools and equipment
yourself.
Phillips screwdriver Needle-nose pliers Wire-stripping pliers
Torx screwdriver Wire crimper
3
Installing the AP
Figure 1 Installation flowchart
Check before installation
Before installing an AP, perform the following tasks:
Connect the AP to the power supply and the network. Examine the LEDs to verify that the AP
can operate correctly. For more information about AP LEDs, see "Appendix B LEDs and ports."
Record the AP MAC address and serial number marked on the rear of the AP for future use.
Installing the AP
Attaching the mounting bracket to an electrical outlet box
As shown in Figure 2, use the M4 screws to attach the mounting bracket to an electrical outlet box.
4
Figure 2 Attaching the mounting bracket to an electrical outlet box
Connecting cables
Connect the network cable from the box to the Uplink/PoE In port on the rear of the AP. Connect a
cable to the Pass Through port on the rear of the AP as required.
NOTE:
The Pass Through ports on the rear and right side of the AP are standard RJ-45 ports. You can
connect telephone cables or other cables to them as needed.
Figure 3 Connecting cables
5
Installing the AP
1. Align the installation hole in the rear of the AP with the standout on the mounting bracket.
Figure 4 Aligning the AP installation hole with the mounting bracket standout
2. Push the AP onto the mounting bracket, and then slide it down until it is fully engaged. Then
secure the AP to the bracket by using the M2.9 × 4 security screw, as shown in Figure 5.
6
Figure 5 Securing the AP on the mounting bracket
Connecting the AP to the power supply
You can power the AP with local power or by using 802.3af- or 802.3at-compliant PoE.
Check before power-on
Check the following items before powering on the AP:
To power the AP with local power, make sure the local power supply is reliably grounded.
To power the AP through PoE, make sure the PoE power supply (PSE) is reliably grounded.
To power the AP through PoE injector, make sure the PoE power supply (PSE) is reliably
grounded.
Connecting the PoE power supply
Use a network cable to connect the Uplink/PoE In port on the AP to a switch that supports PoE.
12
7
Figure 6 Connecting the PoE power supply
Connecting the local power supply
NOTE:
The Power adapter must be ordered separately.
Table 1 Power adapter specifications
Item Specification
Input 100 VAC to 240 VAC
Output
+54 VDC at 0.74 A
You can power the AP by using an power adapter. Use the power adapter to connect the power port
of the AP to the local power source.
Figure 7 Connecting the local power supply
8
PoE injector power supply
CAUTION:
A PoE injector must be used together with an LPS-compliant adapter provided by H3C.
The PoE injector must be ordered separately.
Connect the PoE injector to the AP and a switch with Ethernet cable. Use the power adapter to
connect the power port of the PoE injector to the local power source.
Connect the PoE injector as shown inFigure 8
Figure 8
PoE injector power supply
Check after power-on
Verify that the AP is powered on and operating correctly by examining the AP status LED. For more
information about AP LEDs, see "Appendix B LEDs and ports."
Connecting the AP to the network
For Internet or MAN access, connect an Ethernet port on the AP to an Ethernet port on an Ethernet
switch, and then verify that the AP has been connected to the network.
The AP can only act as a fit AP, and all fit AP settings are configured on the AC. Execute the display
wlan ap all command on the AC that connects to the fit AP. If the AP status is R/M, the AP is
connected to the network.
<Sysname> display wlan ap all
Total number of APs: 1
Total number of connected APs: 1
Total number of connected manual APs: 1
Total number of connected common APs: 0
Total number of connected WTUs: 0
Total number of inside APs: 0
Maximum supported APs: 3072
Remaining APs: 3071
9
Total AP licenses: 128
Local AP licenses: 128
Server AP licenses: 0
Remaining local AP licenses: 127
Sync AP licenses: 0
AP information
State : I = Idle, J = Join, JA = JoinAck, IL = ImageLoad
C = Config, DC = DataCheck, R = Run, M = Master, B = Backup
AP name AP ID State Model Serial ID
ap1 1 R/M WA510H 219801A1NS8182032235
10
Appendix A Technical specifications
Table 2 WA510H specifications
Item Specification
Protocol IEEE802.11a/b/g/n/ac Wave2
Radio Two
Dimensions (H × W × D) 150 × 86 × 36.8 mm (5.91 × 3.39 × 1.45 in)
Weight 250 g (0.55 lb)
Built-in antenna
2.4 G antenna: 3.46 dBi peak gain
5 G antenna: 3.40 dBi peak gain
Maximum power consumption 12.95 W
11
Appendix B LEDs and ports
LEDs
Figure 9 LEDs on the AP
(1) Power LED (2) Radio LED
(3) Uplink LED (4) Ethernet port LEDs
Table 3 LED description
Mark Status Description
Power LED
Off The AP is not powered on.
Steady yellow An exception has occurred during AP initialization.
Flashing yellow (1 Hz) No radio card is detected.
Flashing yellow (2 Hz)
The Ethernet interfaces are shut down and no mesh link
is present.
Flashing green (0.5 Hz) The AP has started up but is not connected to any AC.
Flashing green (2 Hz) The AP is updating applications.
Steady green The AP is operating correctly.
Radio LED
Off
No clients are associated with the AP or the LED is
disabled from the CLI.
Flashing green (1 Hz) The 2.4 G radio has associated clients.
Flashing yellow (1 Hz) The 5 G radio has associated clients.
Alternating green and yellow
(1 Hz)
Both the 2.4 G and 5 G radios have associated clients.
12
Mark Status Description
Uplink LED
Off No link is present on the port.
Steady yellow The negotiated rate is 10/100 Mbps.
Flashing yellow
The uplink port is sending or receiving data at 10/100
Mbps.
Steady green The negotiated rate is 1000 Mbps.
Flashing green
The uplink port is sending or receiving data at 1000
Mbps.
Ethernet port
LED
Off No link is present on the port.
Steady yellow The negotiated rate is 10/100 Mbps.
Flashing yellow
The Ethernet port is sending or receiving data at 10/100
Mbps.
Steady green The negotiated rate is 1000 Mbps.
Flashing green
The Ethernet port is sending or receiving data at 1000
Mbps.
Ports
The AP provides the following ports:
One console port.
Four 10/100/1000 Mbps copper Ethernet ports.
One power port.
Two Pass Through ports.
One Uplink/PoE In port.
One USB port.
NOTE:
The AP also has a reset button.
13
Figure 10 Bottom view
(1) 10/100/1000 Mbps copper Ethernet port (2) Uplink/PoE In port
(3) Pass Through port
Figure 11 Right side view
(1) Pass Through port (2) Power port
(3) Reset button (4) USB port
(5) Console port
Table 4 Port description
Port Standards and protocols Description
CONSOLE RS/EIA-232
The console port is used for configuration and
management.
NOTE:
Only the maintenance staff can use the console port.
ETH
IEEE802.3
IEEE802.3u
IEEE802.3af
The 10/100/1000 Mbps copper Ethernet port acts as a
downlink interface. Ports 1 through 4 are represented by
GE1/0/2 through GE1/0/5, respectively.
Uplink/PoE In
IEEE802.3
IEEE802.3u
IEEE802.3af
The 10/100/1000 Mbps copper Ethernet port can act as
an uplink interface connecting to Internet or MAN and
receive PoE power supply at the same time. It is
represented by interface GE1/0/1.
DC 54V N/A The port receives +54 VDC power from the local supply.
Pass Through
IEEE802.3
IEEE802.3u
The port is used for telephone cable or RJ-45 cable
connection.
USB USB2.0 The port is used for data reading and writing and charging.
1
3
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

H3C WA510H Installation guide

Category
Network switches
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI