Contents
Nomenclature......................................................................................................................1
Indoor Unit .....................................................................................................................1
Outdoor Unit ..................................................................................................................3
Product Line-Up .............................................................................................................4
Features.............................................................................................................................10
Application Information ................................................................................................... 11
Operating Range ......................................................................................................... 11
Refrigerant Circuit Diagram .........................................................................................12
Controller ....................................................................................................................14
Installation Guideline ...................................................................................................17
Engineering & Physical Data ...........................................................................................42
General Data - Heat pump ..........................................................................................42
Components Data - Heat pump ...................................................................................48
Performance Data .............................................................................................................54
Outline and Dimension ....................................................................................................57
Electrical Data ...................................................................................................................61
Wiring Diagram .................................................................................................................63
Service and Maintenance.................................................................................................70
Troubleshooting ...............................................................................................................72
Exploded View and Part List ...........................................................................................82
Nomenclature A5MSY-2010
1
Nomenclature
Indoor Unit
A 5 WM Y 10 J R
Brand
A : Acson
Refrigerant
5 : R410A
Model Name
WM : Wall Mounted
Inverter System Type
Y : Y series
Capacity Index
10
15
20
25
: 10,000 Btu/h
: 15,000 Btu/h
: 20,000 Btu/h
: 25,000 Btu/h
Chassis
J : J Series
Model Type
“ “
R
: Omitted if cooling only
: Heatpump
A5MSY-2010 Nomenclature
2
Indoor Unit
A 5 CK Y 10 C R
Brand
A : Acson
Refrigerant
5 : R410A
Model Name
CK
CC
CM
: Ceiling Cassette
: Ceiling Concealed
: Ceiling Mounted
Inverter System Type
Y : Y series
Capacity Index
10
15
20
25
: 10,000 Btu/h
: 15,000 Btu/h
: 20,000 Btu/h
: 25,000 Btu/h
Chassis
C
E
: C Series
: E Series
Model Type
“ “
R
: Omitted if cooling only
: Heatpump
Nomenclature A5MSY-2010
3
Outdoor Unit
A 5 MS Y 20 B R
Brand
A : Acson
Refrigerant
5 : R410A
Model Name
MS : Multi Split Condensing Unit
Inverter System Type
Y : Y series
Capacity Index
20
25
30
: 20,000 Btu/h
: 25,000 Btu/h
: 30,000 Btu/h
Chassis
B : B Series
Model Type
“ “
R
: Omitted if cooling only
: Heatpump
4
A5MSY-2010 Product Line-Up
Product Line-Up
Indoor Unit
A5WMY-J Series
A5WMY
Nomenclature
Classi cation
Handset
PCB
Air Puri cation
Marking
Others
GS01
W_2_03A
Saranet Filter
Negative Ionizer
Nano Technology Air Filtration
CE
Auto Restart
HEATPUMP
10JR ACLTC X X X X X
15JR ACLTC X X X X X
20JR ACLTA X X X X X
25JR ACLTA X X X X X
5
Product Line-Up A5MSY-2010
Indoor Unit
A5CKY-C Series
A5CKY
Nomenclature
Classi cation
Handset
PCB
Air Puri cation
Marking
Others
GS01
C_2_01A_M
Saranet Filter
Negative Ionizer
Nano Technology Air Filtration
CE
Auto Restart
HEATPUMP
10CR ACOA X X X
15CR ACOA X X X
20CR ACOA X X X
PLCKYCR NGS01 X X X
6
A5MSY-2010 Product Line-Up
Indoor Unit
A5CKY-E Series
A5CKY
Nomenclature
Classi cation
Handset
PCB
Air Puri cation
Marking
Others
GS01
C_2_01A_M
Saranet Filter
Negative Ionizer
Nano Technology Air Filtration
CE
Auto Restart
HEATPUMP
20ER ACOA X X X
25ER ACOA X X X
PLCKYER NGS01 X X X
7
Product Line-Up A5MSY-2010
Indoor Unit
A5CCY-C Series
A5CCY
Nomenclature
Classi cation
Handset
PCB
Air Puri cation
Marking
Others
Netware 3C
C_2_01A_M
Saranet Filter
Negative Ionizer
Nano Technology Air Filtration
CE
Auto Restart
HEATPUMP
10CR ACPA X X X X X
15CR ACPA X X X X X
20CR ACPA X X X X X
25CR ACPA X X X X X
8
A5MSY-2010 Product Line-Up
Indoor Unit
A5CMY-E Series
A5CMY
Nomenclature
Classi cation
Handset
PCB
Air Puri cation
Marking
Others
GS01
C_2_01A_M
Saranet Filter
Negative Ionizer
Nano Technology Air Filtration
CE
Auto Restart
HEATPUMP
15ER ACAA X X X X X
20ER ACAA X X X X X
25ER ACAA X X X X X
9
Product Line-Up A5MSY-2010
Outdoor Unit
A5MSY-BR
A5MSY
Nomenclature
Classi cation
Refrigerant
Control
Fin
Safety Devices
Compressor
Marking
Others
Cap Tube
EXV
Gold coated
Blue coated
Bare
Contactor
HP
LP
DC Inverter Swing
CE
Drain Elbow
HEATPUMP
20BR ACDOA
XX XXX
25BR ACDOA
XX XXX
30BR ACDOA
XX XXX
10
A5MSY-2010 Features
Features
Self Diagnosis
The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the
system. The error will be re ected by the blinking of the LED lights.
Advance Technology
Incorporating fuzzy logic control enables greater exibility in system control handling to achieve
Powerful, ef cient and economical operation.
Even room temperature control.
Constant and quiet compressor operation.
Enhanced system reliability and reduced maintenance costs.
On / Off Button on Indoor Unit
On/Off button is provided on the front panel of the unit. It can be used when the remote controller is missing or
if its battery has run out. (Note: This button can also be used for forced operation mode)
Wireless Remote Controller
The compact LCD transmitter is able to operate the air conditioner unit within the distance of 8 meters.
Fan speed can be set at high / medium / low / super low or automatic.
Sleep mode auto control will gradually increase or decrease the setting temperature to provide a
comfortable surrounding for sleeping.
Air ow direction can be controlled automatically.
Room temperature is controlled by electronic thermostat.
The real time timer allows the air conditioner to be switched On and Off automatically based on user
settings.
Turbo mode function is available to enables the required set temperature to be achieved in a short time.
Personalized Setting allows user to preset and store 2 groups of personal settings (including timer setting)
in the handset.
Higher Energy Savings
The inverter compressor is programmed to run at the optimum speed. This is controlled by input frequency that
varies according to the indoor load requirements.
Once the indoor set temperature is achieved, the input frequency supply to the compressor will be reduced.
Hence, less power is required to maintain the unit operation and this will consume less energy.
Improved Compressor Life Span
For this multi-split inverter system, once the unit is started, the compressor rotation speed is steadily ramp up
or down based on load requirement throughout the operation. This control method gives the compressor motor
a smooth operation. It helps to reduce the wear and tear of the compressor motor. In the long run, the life span
of compressor is increased.
Overheating Protection (for heat pump unit only)
In case the internal and/or the external temperature are too high, or the lter is dirty and clogged up, the
refrigerant may be overheated. The compressor will reduce its running speed in order to lower the temperature
of heat exchanger. If the temperature is still very high, the compressor will stop.
11
Application Information A5MSY-2010
Application Information
Operating Range
Ensure the operating temperature is in allowable range.
Heatpump
Heating
Outdoor temp. (°CWB)
Indoor temp. (°CDB)
Cooling
Outdoor temp. (°CDB)
Indoor temp. (°CWB)
-16
15 20 27
18
Standard
point
Caution :
The use of your air conditioner
outside the range of working
temperature and humidity can result
in serious failure
.
0
46
43
12 2319
10
12
A5MSY-2010 Application Information
Refrigerant Circuit Diagram
Model: A5MSY20BR
13
Application Information A5MSY-2010
Refrigerant Circuit Diagram
Model: A5MSY25BR
A5MSY30BR
14
A5MSY-2010 Application Information
Controller
GS01
SWING
TURBO
QUIET SLEEP
ON
CANCEL
CANCEL
OFF
TIMER
CLOCK
MODE
FAN
8
6
7
9
11
1
2
3
4
5
13
12
10
15
Application Information A5MSY-2010
1 Transmission source
The source where the signal will be transmitted.
2 Signal transmission indication
Blink to con rm that the last setting has been transmitted
to the unit.
3 “ON/OFF” Button
Press once to start the air conditioner unit.
Press again to stop the unit.
4 Fan Speed Selection
Press the
button continuously will toggle the fan speed
in the following order:
Low p Med p High p Auto
Stop pressing when the desired fan speed appears on the
display screen.
5 Operation mode
Press the MODE button to select the type of operating
mode.
For cooling only unit, the available modes are: COOL (
7
),
DRY (6) and FAN (
).
For heat pump unit, the available modes are: AUTO (U),
COOL (
7
), DRY (6), FAN ( ) and HEAT ( ).
The AUTO (U) mode is unavailable for chilled water
system.
6 Automatic air swing
Press the SWING
button to activate the automatic air
swing function.
To distribute the air to a speci c direction, press the
SWING button and wait until the louver move to the
desired direction and press the button once again.
Swing mode selection method (for CK-E model)
Press SWING (
) button for 4 seconds to enter eld
setting mode. While in eld setting mode, it will only show
SWING MODE ( ).
Press temperature and button to select SWING MODE ( )
rotation from Swing Mode 1 to Swing Mode 3.
There are 3 different SWING MODE, which are:
Swing mode 1 Swing mode 2 Swing mode 3
SWING MODE will not activate unless SWING is activated.
Swing is indicated by the logo:
If no mode changes within 4 seconds, unit will operate
according to the selected SWING MODE ( ).
7 Turbo function (model dependent)
Press for fast cooling or heating operation.
Fan speed turn to maximum speed.
Press again to deactivate the function.
Available under HEAT, COOL and DRY modes only.
Any change of fan speed will deactivate this function.
The Turbo function ( ) is unavailable for chilled water
system and remote control with SWING MODE ( )
function.
8 OFF timer setting
Press the TIMER OFF button will activate the off timer
function.
Set the desired off time by pressing the TIMER OFF button
continuously.
Press the CANCEL button to cancel the off timer setting.
9 Quiet function (model dependant)
Press
for quiet operation.
Fan speed turn to minimum speed.
Press again to deactivate the function.
Any change of fan speed will deactivate this function.
The Silent function ( ) is unavailable for chiller water
system.
10 Clock time setting
Press and hold
button to set the clock time.
11 ON timer setting
Press the TIMER ON button will activate the on timer
function.
Set the desired on time by pressing the TIMER ON
button continuously. If the timer is set to 7.30am, the air
conditioner will turn on at 7.30am sharp.
Press the CANCEL button to cancel the on timer setting.
12 Sleep mode setting
Press the button will activate the sleep mode function.
This is an energy
saving option. When
the unit is operating
under cooling mode,
the set temperature is
increased by 0.5°C
after the rst half an
hour, another 0.5°C
after the second half an
hour and 1°C after the
following 1 hour.
When the unit is
operating under
heating mode, the set
temperature is decreased by 1°C after the rst half an
hour, another 1°C after the second half an hour and 1°C
after the following 1 hour.
This function is available under COOL, HEAT and AUTO
mode.
13 Temperature setting
To set the desired room temperature, press the * or *
button to increase or decrease the set temperature.
The temperature setting range is from 16°C to 30°C
(Optional setting 20°C to 30°C).
Press both buttons S and T simultaneously to toggle from
°C to °F setting.
+2 C
+1 C
-1C
-2C
00.51 1.52
-3C
Operation Guide
16
A5MSY-2010 Application Information
Controller
Netware 3C
1 ON/OFF Button
Starting Operation:
When the unit is turned off, press the ON/OFF button.
The operation LED lights and the unit is turned on.
Stopping Operation:
When the unit is turned on, press the ON/OFF button. The
operation LED is extinguished and control are turned off.
2 SLEEP Button
Press SLEEP button to activate the sleep mode or energy
saving mode.
3 FAN Button
Press FAN button to select AUTO, HIGH, MEDIUM or LOW
fan speed.
4 MODE Button
Press the MODE button to switch operation from COOL,
HEAT, DRY, FAN.
Check the display to see in which mode the control is set.
5,6 or ‘ Set Temperature Button
Press the temperature button and set the temperature
of your choice. By pressing the ‘ or ‘’ button once,
temperature changes by 1°C [or 1°F].
Temperature can be set within the range 16°C~30°C
(61°F~86°F)
During fan mode, temperature cannot be set.
If pressing ‘ and ‘’ together, the unit of temperature will
change from °C to °F and vice-versa.
7 SWING button
Press SWING button to activate the air sweep function.
8 ON TIMER Button
Enable/disable the Event 1, 2 and 3 ON TIMER setting
mode
9 OFF TIMER Button
Enable/disable the Event 1, 2 and 3 OFF TIMER setting
mode
10 Timer Active Button
These timers will not triggered if the timer is not active.
To activate the timers, press the TIMER ACTIVE key
unit “TIMER ACTIVE” appears on LCD. This symbol is to
indicate Event 1, Event 2 and/or Event 3 timers are active.
Pressing the same steps will deactivate the timers and
“TIMER ACTIVE” symbol will disappear.
Another method to cancel the timers setting is changed all
the hour setting of the timers to null one by one. When the
setting is null, the LCD display --:--, then this respective
timer will be disable.
11 CLOCK Button
Enable/disable the Real Time Clock (RTC) setting mode
12 DAY Button
a) Select the day for RTC or timer setting
b) Enable/disable FAN Key lock
13 HOUR Button
a) Select the hour for RTC or timer settings
b) Set Override function for 1, 2 or 4 hours
14 MINUTE Button
a) Select the minute for RTC or timer settings
b) Enable/disable key lock
17
Application Information A5MSY-2010
Installation Guideline
Safety Precautions
WARNING
CAUTION
Installation and maintenance should be performed by qualifi ed
persons who are familiar with local code and regulation, and
experienced with this type of appliance.
All fi eld wiring must be installed in accordance with the national
wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the
name plate before commencing wiring work according to the wiring
diagram.
The unit must be GROUNDED to prevent possible hazard due to
insulation failure.
All electrical wiring must not touch the refrigerant piping or any
moving parts of the fan motors.
Confi rm that the unit has been switched OFF before installing or
servicing the unit.
Disconnect from the main power supply before servicing the air
conditioner unit.
DO NOT pull out the power cord when the power is ON. This may
cause serious electrical shocks which may result in fi re hazards.
Keep the indoor and outdoor units, power cable and transmission
wiring, at least 1m from TVs and radios, to prevent distorted
pictures and static. {Depending on the type and source of the
electrical waves, static may be heard even when more than 1m
away}.
Please take note of the following important points
when installing.
Do not install the unit where leakage of ammable
gas may occur.
If gas leaks and accumulates around the unit, it
may cause reignition.
Ensure that drainage piping is connected properly.
If the drainage piping is not connected properly,
it may cause water leakage which will dampen
the furniture.
Do not overcharge the unit.
This unit is factory pre-charged. Overcharge will
cause over-current or damage to the compressor.
Ensure that the unit’s panel is closed after service
or installation.
Unsecured panels will cause the unit to operate
noisily.
Sharp edges and coil surfaces are potential
locations which may cause injury hazards. Avoid
from being in contact with these places.
Before turning off the power supply, set the remote
controllers ON/OFF switch to the “OFF” position
to prevent the nuisance tripping of the unit. If this is
not done, the unit’s fans will start turning automatically
when power resumes, posing a hazard to service
personnel or the user.
Do not operate any heating apparatus too close to the
air conditioner unit. This may cause the plastic panel to
melt or deform as a result of the excessive heat.
Ensure the color of wires of the outdoor unit and
the terminal markings are same to the indoors
respectively.
IMPORTANT : DO NOT INSTALL OR USE THE
AIR CONDITIONER UNIT IN A LAUNDRY ROOM.
Do not use joined and twisted wires for incoming
power supply.
NOTICE
Disposal requirements
Your air conditioning product is marked with this symbol. This means that electrical and electronic products
shall not be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of
the refrigerant, of oil and of other parts must be done by a qualied installer in accordance with relevant
local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential
negative consequences for the environment and human health. Please contact the installer or local authority
for more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant
local and national legislation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98

Acson A5MSY25BR User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI