Sensor: 2.5”H x 1”W x .5”D
Wireless signal range: 600ft (200M), open air.
Code outputs: tamper, tamper restore, alarm (primary open), alarm restore
(primary close), external alarm (secondary wired open), external restore
(secondary wired closed), low battery.
Transmitter frequency: 319.5 MHz
Unique code ID
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m
Operating Temperature: -10C~50C
Relative Humidity: 5-95% Non-Condensing
Storage Temperature: -40-80C
Replace battery with exact replacement every 5 years with 3V CR2032
Lithium (x2).
SEE REVERSE FOR REMAINING STEPS
USING EXTERNAL TERMINALS
Connect wired devices such as
garage door contacts, door window
contacts, and panic switches using
the external terminals. Wire lead
length should not exceed 20’.
Safes
Cabinets
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
STEP
2
STEP
3
REMOVE
BATTERY
TABS
STEP
4
LINE UP
SENSOR &
MAGNET
STEP
5
SECURE
SENSOR &
MAGNET
STEP
6
LEARN
INTO
PANEL
Document#: IQMDWEXTS-QG-08-18
Revision#: 8/7/18
Issue Date: AUG 2018
Qolsys Product #: QS1137-840
Test sensor before
placing. Gap should not
exceed .6”.
Includes rare earth magnet for
expanded gap forgiveness.
Magnet locator mark
Magnet
Sensor
APPLY
ADHESIVE
up to .6”
To reduce risk of damage over time, place
the sensor on the frame and the magnet
on the door or window itself.
Place your panel in
autolearn" mode
Customize name and settings
as desired and and touch “ADD”
ADD
Open and close the case
to “tamper” the device
TechSupport@Qolsys.com
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2ABBZ-RF-MDWS-ITI-S
IC: 11817A-RFMDWSITIS
CONTACT TECH SUPPORT
GOT QUESTIONS?
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
SECURE
CONNECTS
USING
319.5 MHz
  • Page 1 1
  • Page 2 2

QOLSYS QS1137-840 Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI