  • Hello! I am an AI chatbot trained to assist you with the Triton Systems RL1600 Series Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TDN 007103-00187
THIS AREA FOR SERVICE PROVIDER
CONTACT INFORMATION:
May 1 2009
Model RL1600
QUICK REFERENCE GUIDE
0$1$*(0(17)81&7,216
$&&(66,16758&7,216
 $7$70:(/&20(6&5((135(66$1'+2/''2:17+(&75/!
.(</2:(55,*+7&251(52).(<3$'35(66!.(<7+(15(
/($6(%27+.(<67+(7230(18:,//%(',63/$<('
 $
77+(7230(186(/(&70$1$*(0(17)81&7,216237,21(17(5
3$66:25'
$1'6(/(&7(17(5!7+(0$1$*(0(17)81&7,216
0$,10(18,6',63/$<('
',$*1267,&6
385*(7+,6,16758&767+(',63(16(5725(029($1<127(6-$06,1
)(('
3$7+
)
2//2:$&&(66,16758&7,21672(17(50$1$*(0(17)81&7,2166(
/(&7',$*1267,&6!',63(16(5
7(67',63(16(
7+,6,16758&767+(',63(16(572',63(16(0,1,080
21(
127()520($&+,167$//('&$66(77(,1727+(5(-(&7&$66(77(
$5($
5(6(77(675(&(,3735,17(57+,6,16758&767+(35,17(5725(
,1,7,$/,=($1'3(5)250$7(6735,17287
6
(/(&7',$*1267,&6!35,17(5
5(67$576+87'2:17(50,1$/
5(67$577(50,1$/7+,6)81&7,215(%22767+(7(50,1$/
)
2//2:$&&(66,16758&7,21672(17(50$1$*(0(17)81&7,2166(
/(&76<67(03$5$0(7(56
6+87'2:17(50,1$/
7+,6)81&7,2132:(56'2:17+(7(50,
1$/623(5$7,1*6<67(0:+(1352037('7+$76+87'2:1,6&203/(7(
7851212))6:,7&+2132:(56833/<722))!326,7,21
'$<&/26(7+,6237,21,686('72&203/(7('$,/<%$/$1&,1*2)7+(
$70:,7+7+(352&(6625727$/6$5(&/($5('$1'6:,7&+('727+(
1(;7
%86,1(66'$<
35,17/$67;7
29,(:35,1735(9,286/<$8',7('2581$8',7('
5(&25'6
86(7+(35,17/$67;237,21
)
2//2:$&&(66,16758&7,21672(17(50$1$*(0(17)81&7,2166(
/(&77(50,1$/&/26()81&7,216
&/26()81&7,216
75,$/&/26(7+,6237,21)81&
7,216/,.($'$< &/26((;&(377+(
727$/6
$5(127&/($5('
-2851$/)81&7,216
)2//2:$&&(66,16758&7,21672(17(50$1$*(0(17)81&7,2166(
/(&7-2851$/
(;$03/((17(5,1*7+(180%(5µ¶:,///(7<289,(:7+(/$6775$16$&7,216(9(1767+$7+$9(2&
&855('<280$<35,17727+(5(&(,3735,17(5
7(50,1$/&21),*85$7,215(3257
)2//2:$&&(66,16758&7,21672(17(50$1$*(0(17)81&7,2166(
/(&7',$*1267,&6!7(50,1$/67$786
&21),*85$7,216800$5<7+,66800$5<,6$&2035(+(16,9(
5(3257
2)&855(177(50,1$/&21),*85$7,21$1'+$5':$5(67$786,1
)250$7,21
127(,7,6+,*+/<5(&200(1'('7+$77+,65(3257%(35,17('$1'6$9('$)7(5,1,7,$/6(783$1':+(1(9(5
&+$1*(6
$5(0$'(727+(7(50,1$/6&21),*85$7,21
4
CASSETTE CLOSE FUNCTIONS
FOLLOW ACCESS INSTRUCTIONS TO ENTER MANAGEMENT FUNCTIONS. SELECT TERMINAL CLOSE FUNCTIONS.
SELECT CASSETTE CLOSE.
nSELECT CASSETTE(S) TO CLOSE. A CHECK MARK ( ) IDENTI-
FIES WHICH CASSETTE(S) ARE SELECTED. PRESS <ENTER>.
pREMOVE AND REPLENISH THE SELECTED CASSETTE(S).
PROCEDURES FOR SPECIFIC DISPENSING MECHANISMS CAS-
SETTE REPLENISHMENT ARE ON THE FOLLOWING PAGES.
rPLACE SELECTED CASSETTE(S) IN SERVICE. PRESS <EN-
TER>.
sENTER CASSETTE QUANTITY (NUMBER OF NOTES, NOT
VA L U E ) FOR THE SELECTED CASSETTE(S). PRESS <ENTER> TO
ACCEPT
ENTRY. REPEAT FOR EACH SELECTED CASSETTE.
oA CLOSE REPORT IS DISPLAYED TO BE PRINTED OR SAVED.
T
HIS OPERATION WILL RESET THE NUMBER OF BILLS IN THE
CASSETTE(S) TO ZERO (0). PRESS <ENTER>.
qAFTER CASSETTE(S) HAVE BEEN REINSERTED IN THE DIS-
PENSER, PRESS <ENTER>.
tA TRIAL CASSETTE CLOSE REPORT AUTOMATICALLY IS
DISPLAYED
TO BE PRINTED OR SAVED. PRINT AND RETAIN A COPY
FOR
STARTING POINT REFERENCE. PRESS <ENTER> TO RETURN TO
CLOSE FUNCTIONS.
5
3
1
2
6
REMOVE ANY REJECTED NOTES FROM THE REJECT
COMPARTMENT. DO NOT RECYCLE REJECTED NOTES!
5
UNLOCK/OPEN DISPENSER SECURITY DOOR. GRASP
T
RAY HANDLE AND REMOVE NOTE CASSETTE
STEP ACTION
STEP
ACTION
PLACE CURRENCY IN THE CASSETTE. SLOWLY PUSH
PACKER FORWARDS AGAINST THE NOTES.
GRASP THE HANDLE AND SLIDE THE NOTE CASSETTE
FULLY INTO THE DISPENSER.
MOVE THE PUSHER PLATE TO THE REAR OF THE TRAY
(TOWARDS THE HANDLE).
4
COUNT THE NUMBER OF BILLS THAT REMAIN IN THE
CASSETTE, IF ANY.
C
OUNT THE NUMBER OF BILLS THAT ARE BEING ADDED
TO THE REMAINING NOTES.
T
HE TOTAL OF THESE AMOUNTS WILL BE ENTERED
IN THE “ENTER CASSETTE QUANTITYPROMPT FOR
C
ASSETTE CLOSE PROCEDURE.
REPLENISH MINI MECH CASSETTE
6
1
4
2
5
3
6
STEP
ACTION
REPLENISH RECEIPT PAPER
STEP
ACTION
OPEN CONTROL PANEL. IF PAPER REMAINS ON
ROLL, CUT OR TEAR PAPER BETWEEN ROLL AND
PRINTER.
P
RESS THE MANUAL FEED BUTTON TO CLEAR
REMAINING PAPER FROM FEED PATH.
R
EMOVE SPENT PAPER ROLL AND SPINDLE FROM
PAPER BRACKET.
I
NSTALL NEW PAPER ROLL ONTO SPINDLE.
I
NSERT PAPER/SPINDLE INTO PAPER BRACKET.
P
APER FEEDS FROM TOP OF ROLL!
F
EED END OF PAPER INTO PRINTER TAKE-UP SLOT.
P
APER WILL FEED AUTOMATICALLY THROUGH
THE PRINTER AND SLIGHTLY OUT FRONT OF UNIT.
NOTE: THIS PROCEDURE REQUIRES TERMINAL TO BE POWERED UP.
7
COMBINATION LOCKS
INTRODUCTION
THE SECURITY CABINET CAN BE SECURED USING EITHER A MECHANICAL OR ELECTRONIC COMBINATION LOCK. THIS PAGE COVERS
HOW TO OPERATE THE COMBINATION OF EITHER LOCK. TO CHANGE COMBINATIONS, SEE ATTACHMENT TO THE USER MANUAL.
OPERATING THE MECHANICAL LOCK
U
NLOCKING THE LOCK
THERE ARE TWO MARKS ON THE DIAL RING. THE INDEX AT THE TOP IS USED FOR OPENING THE LOCK, THE INDEX 30 DEGREES TO
THE LEFT IS USED ONLY WHEN CHANGING THE COMBINATION.
T
HE DIAL SHOULD ALWAYS BE TURNED SLOWLY AND EVENLY. A REVOLUTION IS COUNTED EACH TIME THE SELECTED NUMBER IS
ALIGNED WITH THE OPENING INDEX. DO NOT TURN THE DIAL BACK TO COMPENSATE FOR OVER-DIALING A NUMBER. IF, WHEN DIALING
THE COMBINATION, ANY NUMBER IS TURNED BEYOND THE INDEX, THE ENTIRE SEQUENCE MUST BE REPEATED.
UNLOCKING 3-NUMBER COMBINATIONS (FOR EXAMPLE, “25-10-25”) SEE USER MANUAL FOR DEFAULT COMBINATION.
1. TURN THE DIAL TO THE LEFT AT LEAST FOUR (4) COMPLETE TURNS TO CLEAR THE COMBINATION LOCK TO ACCEPT THE
COMBINATION.
2. U
SING THE ‘OPENING INDEX’, TURN THE DIAL TO THE LEFT, STOPPING WHEN ‘25’ IS ALIGNED WITH THE OPENING INDEX,
THE FOURTH TIME.
3. T
URN THE DIAL TO THE RIGHT, STOPPING WHEN ‘10’ IS ALIGNED WITH THE OPENING INDEX, THE THIRD TIME.
4. T
URN THE DIAL TO THE LEFT, STOPPING WHEN ‘25’ IS ALIGNED WITH THE OPENING INDEX, THE SECOND TIME.
5. T
URN THE DIAL SLOWLY TO THE RIGHT UNTIL THE BOLT RETRACTS.
OPERATING THE ELECTRONIC LOCK
THE ELECTRONIC LOCK COMBINATION CONSISTS OF SIX DIGITS. UPON ARRIVAL, THE COMBINATION OF THE LOCK SHOULD ALREADY
BE PRESET TO 1-2-3-4-5-6. NOTE: CHANGE THIS COMBINATION! SEE USER MANUAL FOR COMBINATION CHANGE PROCEDURES.
ENTERING THE COMBINATION
1. ENTER THE CURRENT COMBINATION AND CHECK FOR PROPER OPERATION. AFTER EACH KEYPRESS, THE LOCK WILL BEEP.
A
FTER THE FINAL DIGIT HAS BEEN ENTERED, THE LOCK WILL BEEP TWICE, AND THE OPEN PERIOD WILL BEGIN.
2. W
HEN A VALID COMBINATION HAS BEEN ENTERED, THE OPERATOR WILL HAVE APPROXIMATELY 4 SECONDS TO OPEN THE LOCK.
3. T
O OPEN THE LOCK, TURN THE OUTER DIAL CLOCKWISE.
4. A
FTER THE LOCK IS OPENED, THE CABINET DOOR MAY BE OPENED.
LOCKOUT FEATURE
THE LOCK INCLUDES A ‘WRONG TRY PENALTYLOCKOUT FEATURE THAT PREVENTS ENTRY FROM UNAUTHORIZED PERSONNEL. THIS
FEATURE PERFORMS AS FOLLOWS:


- LED
FLASHES RED AT TEN (10) SECOND INTERVALS.

        
5-
MINUTE DELAY.
/