Barco F70-W8 Installation guide

Type
Installation guide
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 1 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Checklist can be filled out electronically or can be printed and filled out manually.
Reporter
Date of report
Name of reporter
Installer information
Installing company
Address
Phone
Email contact
The installer confirms to be a valid laser show
variance holder
YES
Variance No.
OR
The installer confirms to be trained and
authorized (e.g. by Barco NV)
YES
Authority name
Authority Variance No. if not Barco
NOTE: If the end user intends to change the installation, the end user shall be a laser light show variance holder or
shall be trained and authorized by a laser light show variance holder.
Installers’ on-site representative responsible for safety and compliance
Name
Title
Phone
Venue information
Permanent installation (e.g. cinema theatre)
or temporary installation (e.g. show, gig)
PERMANENT
TEMPORARY
Name of venue
Room number (if applicable)
Address
Phone
Email
Safety Officer, Person responsible for safety of show and operator
Name
Title
Phone
Email
Training and documentation provided to Operator/Owner
Training on the safe operation and maintenance
PASS
FDA/CDRH installation requirements Any modifications must be approved
PASS
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 2 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
List of state, local, and other agencies notified if applicable for RG3
installations
A
B
C
D
Projectors in scope of this registration form
Per projector a Details Projector form page must be filled in this registration document! (see following pages)
Total number of projectors included in this registration form:
Signatures
Installer's signature
Safety officer/ Owner signature
Name:
Name:
Date:
Date:
Signature
Signature
!!! In case the installer is not a laser light show variance holder then this installation checklist must be
completed after the installation and sent to pvg@barco.com !!!
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 3 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 1.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 4 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 2.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 5 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 3.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 6 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 4.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 7 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 5.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 8 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 6.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 9 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 7.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 10 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 8.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 11 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 9.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 12 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 10.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 13 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 11.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 14 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 12.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 15 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 13.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 16 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 14.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 17 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 15.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 18 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 16.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 19 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 17.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
Checklist for laser illuminated RG3 projector installations performed in
the USA
P 20 / 22
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Details Projector 18.
Projector information
Manufacturer
Barco NV
Model
Serial Number
Manufacturing date
Laser Hazard Classification
CLASS 1 RG3
CLASS 2 RG3
OTHER CLASS
CLASS:
Projector and restricted access area inspected
Projector securely mounted
PASS
Projector housing is assembled properly
PASS
Restricted access area and RG3 product warning signs provided
PASS
Readily accessible control provided to immediately terminate projection
light (e.g. mains switch, circuit breaker)
PASS
Restricted access control implemented
(including physical means e.g. key, pass code)
PASS
Clearance distances confirmed
The Hazard Distance (HD) is confirmed to be
Meter
Foot
How high is the lower part of the projected beam above floor level where
audience is permitted to stand (=Separation Height SH)
Meter
Foot
If applicable: How wide is the lateral distance between the projected
beam from where audience is permitted to stand (=Separation Width SW)
Meter
Foot
The installer confirms that the Restriction Zone (RZ) is respected
YES
NO
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Barco F70-W8 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI