ESAB RoboFeed 3004HW, FeedControl 3004HW User manual

Category
Welding System
Type
User manual

This manual is also suitable for

Aristo®
Instruction manual
0463 280 201 GB 20140710 Valid for: serial no. 325-xxx-xxxx, 410-xxx-xxxx
RoboFeed3004HW
FeedControl3004HW
TABLE OF CONTENTS
0463 280 201 © ESAB AB 2014
1 SAFETY ................................................................................................................ 4
2 INTRODUCTION................................................................................................... 7
2.1 Equipment............................................................................................................. 7
3 TECHNICAL DATA ............................................................................................... 8
4 INSTALLATION..................................................................................................... 9
4.1 Terminating resistor.............................................................................................9
4.2 Example of a robotic welding system ................................................................9
5 OPERATION ....................................................................................................... 10
5.1 Connection and control devices....................................................................... 11
5.2 Restrictions regarding the welding torch connector......................................13
5.3 Replacing and inserting wire ............................................................................14
5.4 Changing feed rollers ........................................................................................ 14
5.5 Pressure guard................................................................................................... 14
5.5.1 Adjusting the gas pressure pre-set value for the pressure guard ....................14
5.6 Wire feed pressure.............................................................................................15
6 MAINTENANCE.................................................................................................. 16
6.1 Inspection and cleaning ....................................................................................16
7 ORDERING SPARE PARTS ............................................................................... 17
DIAGRAM ..................................................................................................................18
WEAR PARTS............................................................................................................22
ORDERING NUMBERS.............................................................................................24
ACCESSORIES .........................................................................................................25
Rights reserved to alter specifications without notice.
1 SAFETY
0463 280 201
- 4 -
© ESAB AB 2014
1 SAFETY
Users of ESAB equipment have the ultimate responsibility for ensuring that anyone who
works on or near the equipment observes all the relevant safety precautions. Safety
precautions must meet the requirements that apply to this type of equipment. The following
recommendations should be observed in addition to the standard regulations that apply to
the workplace.
All work must be carried out by trained personnel well-acquainted with the operation of the
equipment. Incorrect operation of the equipment may lead to hazardous situations which can
result in injury to the operator and damage to the equipment.
1. Anyone who uses the equipment must be familiar with:
its operation
location of emergency stops
its function
relevant safety precautions
welding and cutting or other applicable operation of the equipment
2. The operator must ensure that:
no unauthorised person is stationed within the working area of the equipment when it
is started up
no-one is unprotected when the arc is struck or work is started with the equipment
3. The workplace must:
be suitable for the purpose
be free from drafts
4. Personal safety equipment:
Always wear recommended personal safety equipment, such as safety glasses,
flame-proof clothing, safety gloves
Do not wear loose-fitting items, such as scarves, bracelets, rings, etc., which could
become trapped or cause burns
5. General precautions:
Make sure the return cable is connected securely
Work on high voltage equipment may only be carried out by a qualified
electrician
Appropriate fire extinquishing equipment must be clearly marked and close at hand
Lubrication and maintenance must not be carried out on the equipment during
operation
1 SAFETY
0463 280 201
- 5 -
© ESAB AB 2014
WARNING!
Arc welding and cutting can be injurious to yourself and others. Take precautions
when welding and cutting. Ask for your employer's safety practices which should
be based on manufacturers' hazard data.
ELECTRIC SHOCK - Can kill
Install and earth the unit in accordance with applicable standards
Do not touch live electrical parts or electrodes with bare skin, wet gloves or
wet clothing
Insulate yourself from earth and the workpiece
Ensure your working stance is safe
FUMES AND GASES - Can be dangerous to health
Keep your head out of the fumes
Use ventilation, extraction at the arc, or both, to take fumes and gases away
from your breathing zone and the general area
ARC RAYS - Can injure eyes and burn skin
Protect your eyes and body. Use the correct welding screen and filter lens
and wear protective clothing
Protect bystanders with suitable screens or curtains
FIRE HAZARD
Sparks (spatter) can cause fire. Make sure therefore that there are no
inflammable materials nearby
NOISE - Excessive noise can damage hearing
Protect your ears. Use earmuffs or other hearing protection.
Warn bystanders of the risk
MALFUNCTION - Call for expert assistance in the event of malfunction.
Read and understand the instruction manual before installing or operating.
PROTECT YOURSELF AND OTHERS!
CAUTION!
This product is solely intended for arc welding.
CAUTION!
Read and understand the instruction manual before
installing or operating.
CAUTION!
Class A equipment is not intended for use in residential
locations where the electrical power is provided by the
public low-voltage supply system. There may be potential
difficulties in ensuring electromagnetic compatibility of
class A equipment in those locations, due to conducted
as well as radiated disturbances.
1 SAFETY
0463 280 201
- 6 -
© ESAB AB 2014
NOTE!
Dispose of electronic equipment at the recycling
facility!
In observance of European Directive 2012/19/EC on
Waste Electrical and Electronic Equipment and its
implementation in accordance with national law, electrical
and/or electronic equipment that has reached the end of
its life must be disposed of at a recycling facility.
As the person responsible for the equipment, it is your
responsibility to obtain information on approved collection
stations.
For further information contact the nearest ESAB dealer.
ESAB can provide you with all necessary welding protection and accessories.
2 INTRODUCTION
0463 280 201
- 7 -
© ESAB AB 2014
2 INTRODUCTION
The RoboFeed 3004HW and FeedControl 3004HW wire feed unit is intended for MIG/MAG
welding with robotic equipment.
The wire feed unit consists of a drive unit (RoboFeed 3004HW) and a separate electronic
unit (FeedControl 3004HW).
NOTE!
The wire feed unit utilizes the robot's safety system to obtain maximum
interference protection.
ESAB's accessories for the product can be found in the "ACCESSORIES" chapter of
this manual.
2.1 Equipment
The wire feed unit is supplied with an instruction manual and a quick connection for
Marathon Pac™ .
3 TECHNICAL DATA
0463 280 201
- 8 -
© ESAB AB 2014
3 TECHNICAL DATA
RoboFeed 3004HW FeedControl 3004HW
Power supply - 42 V 50-60 Hz
Power requirement - 378 VA
Motor voltage 60 VDC PWM (Pulse Width
Modulation)
-
Motor current I
max
8.0 A 8.0 A
Wire feed speed 0.8 - 30.0 m/min -
Torch connection EURO -
Wire dimension
- Steel (Fe) 0.8-1.6 mm -
- Stainless steel (Ss) 0.8-1.6 mm -
- Aluminum (Al) 1.0-1.6 mm -
- Cored wire (FCW) 0.8-1.6 mm -
Operating temperature -10 to +40°C -10 to +40°C
Transport temperature -20 to +55°C -20 to +55°C
Weight 5.4 kg 4.9 kg
Dimensions (l × b × h) 251 × 182 × 221 mm 330 × 118 × 320 mm
Shielding gas Gases for MIG/MAGwelding Gases for MIG/MAGwelding
- max pressure 0.5 Mpa (5 bar) 0.5 Mpa (5 bar)
Coolant - ESAB's ready-mixed coolant
- max pressure - 0.5 Mpa (5 bar)
Maximum permissible load at
- 60% duty cycle 500 A 500 A
- 100% duty cycle 280 A 280 A
Enclosure class IP2X IP2X
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40°C/104°F.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP2X is intended for indoor use.
Coolant
It is very important to use the ESAB ready-mixed coolant! If other coolants are used the
equipment could be damaged or in worst case the chassis could become live. You can find
the ordering number of ESAB's ready-mixed coolant in the "ACCESSORIES" chapter of the
instruction manual.
4 INSTALLATION
0463 280 201
- 9 -
© ESAB AB 2014
4 INSTALLATION
The installation must be carried out by a professional.
WARNING!
When welding in an environment with increased electrical danger, only power
sources intended for this environment may be used. These power sources are
marked with the symbol .
4.1 Terminating resistor
The ends of the CAN bus must be fitted with terminating
resistors to avoid communication interference.
The terminating resistor is delivered with the power source.
One end of the CAN bus is at the control panel (U8
2
), which
has an integral terminating resistor.
The other end is at the FeedControl and must be fitted with the
terminating resistor, as shown on the right.
If U8
2
is used together with W8
2
, the terminal resistor in the
W8
2
must be disconnected, see the instruction manual for the
W82.
4.2 Example of a robotic welding system
NOTE!
A mounting kit and a cable kit are required for mounting to a robot, please contact
your local ESAB dealer for more information.
5 OPERATION
0463 280 201
- 10 -
© ESAB AB 2014
5 OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!
WARNING!
Assure that the side panels are closed during operation.
WARNING!
Rotating parts can cause injury, take great care.
5 OPERATION
0463 280 201
- 11 -
© ESAB AB 2014
5.1 Connection and control devices
RoboFeed 3004HW
1. Outlet for connection to the drive unit from
the electronic unit
5. Rating plate
2. Connection for shielding gas, in 6. Push button for inching
3. Connection for the welding cable or the
return cable.
7. Push button for gas purging
4. Connection for welding torch (EURO) 8. Quick connector Marathon Pac™
5 OPERATION
0463 280 201
- 12 -
© ESAB AB 2014
FeedControl 3004HW
Shows serial no. 325-xxx-xxxx: Shows serial no. 410-xxx-xxxx:
1. White indicating lamp Power supply ON 9. Rating plate
2. Connection from electronic unit to drive
unit - pulse signal encoder
10. Connection for terminating resistor or
forwarding to next wire feed unit
3. Connection from electronic unit to drive
unit - 42V power
11. Connection for control cable from power
source
4. Connection for spatter removal air, out 12. Connection for shielding gas, in
5. Connection for coolant to welding torch,
BLUE
13. Connection for spatter removal air, in
6. Connection for welding current from drive
unit (OKC)
14. Connection for coolant from power source
(cooling unit), BLUE
7. Connection for coolant from welding torch,
RED
15. Connection for welding current from power
source (OKC)
8. Connection for shielding gas, out 16. Connection for coolant to power source
(cooling unit), RED
Symbol and function explanations
Inlet spatter removal air
Shielding gas
Outlet spatter removal air
Used for spray-cleaning the contact tip on the welding torch.
Gas purging
Gas purging is used when measuring the gas flow or to flush any air or moisture
from the gas hoses before welding starts. Gas purging occurs for as long as the
button is held depressed and occurs without voltage or wire feed starting.
5 OPERATION
0463 280 201
- 13 -
© ESAB AB 2014
Wire inching
Wire inching is used when one needs to feed wire without welding voltage being
applied. The wire is fed as long as the button is depressed.
Shielding gas out
5.2 Restrictions regarding the welding torch connector
Nozzle ordering no. A
0469 837 880, 0469 837 882 3.5 ±0.1
0469 837 881 (Aluminum) 3.0 ±0.1
Dimensions for ESAB EURO connector Recommended dimensions mating parts
5 OPERATION
0463 280 201
- 14 -
© ESAB AB 2014
5.3 Replacing and inserting wire
Open the side panel.
Disconnect the pressure sensor by folding it backwards, the pressure rollers slide up.
Straighten out the new wire 10-20 cm. File off any burrs and sharp edges from the end
of the wire before inserting it into the wire feed unit.
Make sure that the wire goes properly into the feed roller's track and into the outflow
nozzle or wire guide.
Secure the pressure sensor.
Close the side panel.
WARNING!
Risk of crushing when replacing the wire bobbin! Do not use safety gloves when
inserting the welding wire between the feed rollers.
5.4 Changing feed rollers
1. Open the side panel.
2. Disconnect the pressure sensor (A) by folding it
backwards.
The pressure rollers slide up.
3. Disconnect the pressure rollers (B) by turning the axle (C)
1/4 turn clockwise and pulling out the axle.
The pressure rollers disconnect.
4. Disconnect the feed rollers (D) by unscrewing the nuts (E)
and pulling out the rollers.
Install the new feed rollers, by repeating the above-mentioned
steps in the reverse order.
5.5 Pressure guard
The pressure guard interrupts the ongoing welding process if the gas flow drops below
5.0l/min (approximately 0.2bar pressure). When this occurs, an error message is displayed
via the control unit.
5.5.1 Adjusting the gas pressure pre-set value for the pressure guard
This instruction applies to pressure guard with ordering no.
0465490001.
1. Connect a gasflowmeter (ordering no. 0155716880) in series
with the welding torch.
2. Open the gas to the preferred flow.
3. Connect a multimeter over the pressure guard.
4. Turn the adjusting screw on the pressure guard until you reach
the break point.
5. Repeat the test if needed.
6. After having set the correct pre-set value, fasten the adjusting
screw using thread locker (Loctite243 or equivalent).
5 OPERATION
0463 280 201
- 15 -
© ESAB AB 2014
5.6 Wire feed pressure
Figure A Figure B
Start by making sure that the wire moves smoothly through the wire guide. Then set the
pressure of the wire feeder's pressure rollers. It is important that the pressure is not too
high.
To check that the feed pressure is set correctly, you can feed out the wire against an
insulated object, e.g. a piece of wood.
When you hold the welding torch approximately 5 mm from the piece of wood (figure A) the
feed rollers should slip.
If you hold the welding torch approximately 50 mm from the piece of wood, the wire should
be fed out and bend (figure B).
6 MAINTENANCE
0463 280 201
- 16 -
© ESAB AB 2014
6 MAINTENANCE
NOTE!
Regular maintenance is important for safe, reliable operation.
CAUTION!
All warranty undertakings from the supplier cease to apply if the customer
attempts any work to rectify any faults in the product during the warranty period.
6.1 Inspection and cleaning
Wire feed unit
Check regularly that the wire feed unit is not clogged with dirt.
Cleaning and replacement of the wire feed unit mechanism's worn parts should take
place at regular intervals in order to achieve trouble-free wire feed. Note that if
pre-tensioning is set too hard, this can result in abnormal wear on the pressure roller,
feed roller and wire guide.
Welding torch
The wear parts of the welding torch should be cleaned and replaced at regular intervals
in order to achieve trouble-free wire feed. Blow the wire guide clean regularly and clean
the contact tip.
7 ORDERING SPARE PARTS
0463 280 201
- 17 -
© ESAB AB 2014
7 ORDERING SPARE PARTS
CAUTION!
Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
RoboFeed 3004HW is designed and tested in accordance with the international and
European standards IEC/EN 60974-5 and IEC/EN 60974-10. It is the obligation of the
service unit which has carried out the service or repair work to make sure that the
product still conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the back cover of this
document. When ordering, please state product type, serial number, designation and spare
part number in accordance with the spare parts list. This facilitates dispatch and ensures
correct delivery.
DIAGRAM
0463 280 201
- 18 -
© ESAB AB 2014
DIAGRAM
RoboFeed 3004HW & FeedControl 3004HW, valid for serial no. 325-xxx-xxxx
DIAGRAM
0463 280 201
- 19 -
© ESAB AB 2014
DIAGRAM
0463 280 201
- 20 -
© ESAB AB 2014
RoboFeed 3004HW & FeedControl 3004HW, valid for serial no. 410-xxx-xxxx
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

ESAB RoboFeed 3004HW, FeedControl 3004HW User manual

Category
Welding System
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI