Follett Horizon HCD1400NVS Installation Instructions Manual

Type
Installation Instructions Manual

This manual is also suitable for

Order parts online
www.follettice.com
Horizon
Icemaker Installation Instructions
for Vision
Satellite- ll
Applications
208264
208264
Stock Module Identification Plate
Stock Module Identification Plate
Service No.
Service No.
Module No.
Module No.
Product
Product
R
E
F
R
IG
ER
A
N
T
R
E
F
RI
G
E
R
A
N
T
M
O
D
E
L
M
O
D
E
L
M
O
T
O
R
C
O
M
P
R
E
S
S
O
R
T
H
E
R
M
A
L
L
Y
P
R
O
T
E
C
T
E
D
M
O
T
O
R
C
O
M
P
R
E
S
S
O
R
T
H
E
R
M
A
LL
Y
P
R
O
T
E
CT
E
D
E
a
s
t
on
P
e
n
n
s
y
l
v
a
n
i
a
E
a
s
t
o
n
P
e
n
n
sy
l
v
a
n
i
a
F
U
L
L
L
OA
D
A
MP
S
F
U
L
L
L
OA
D
A
M
P
S
M
A
X
.
B
R
A
N
CH
CI
R
CU
I
T
F
U
S
E
S
I
Z
E
M
A
X
.
B
R
A
NC
H
C
I
R
C
U
I
T
F
U
S
E
S
I
Z
E
M
I
N
.
B
R
A
N
CH
CI
R
CU
I
T
A
M
P
A
CI
T
Y
M
I
N
.
B
R
A
N
C
H
C
I
R
C
U
I
T
A
M
P
A
C
I
T
Y
D
E
S
IG
N
P
R
E
S
S
U
R
E
HIG
H
S
ID
E
D
E
S
IG
N
P
R
E
S
S
U
R
E
HIG
H
S
ID
E
A
M
PS
AM
PS
A
M
PS
A
M
PS
V
O
L
T
S
V
O
L
T
S
C
O
R
P
O
R
A
T
IO
N
C
O
R
P
O
R
A
T
IO
N
S
E
R
IA
L
N
O
S
E
R
IAL N
O
P
H
A
S
E
P
H
A
S
E
S
I
N
G
L
E
S
I
N
G
L
E
C
HA
R
G
E
CH
A
R
G
E
L
O
W
S
ID
E
L
O
W
S
ID
E
P
A
R
T
N
O
P
A
R
T
NO
PS
I
G
PS
I
G
T
H
E
U
S
A
T
H
E
U
S
A
M
A
D
E
I
N
M
A
D
E
I
N
O
Z
OZ
R
C
R
H
Z
H
Z
U
L
L
NS
F
N
SF
U
HCD1000RVS, HCD1400RVS, HCD1000NVS, HCD1400NVS,
(See model number con gurator on page 2 for details.)
00159988R03
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
remote condensing
2
remote condensing VISION • SATELLITE-FILL
Horizon Series Icemaker Model Number Configurations
A Air-cooled, self-contained
W Water-cooled, self-contained
R Air-cooled, remote condensing unit
N Air-cooled, no condensing unit for
connection to parallel rack system
A V SC 1400HC
HC Horizon
Chewblet
HM Horizon
MINI
Chewblet
C 208-230/60/1
(self-contained only)
D Low side 115/60/1
Condensing unit
208-230/60/1
(remote condensing only)
E 230/50/1
(self-contained only)
Icemaker Voltage Series Condenser
V Vision™
H Harmony™
B Ice storage
bin
J Drop-in
M Ice Manager
diverter valve
system
1000 up to
1036 lbs
(471kg)
1400 up to
1450 lbs
(658kg)
S Satellite-fill™
T Top-mount
Application Configuration
† Ice Manager Diverter Valve Systems can be used to fill any two of these bins or dispensers with a single ice machine.
3
VISION • SATELLITE-FILL remote condensing
Front cover
8
Internal connection
7
Ice transport tube
5
External connection
6
Louvered docking assembly
4
Dispenser preparation
3
Site preparation
2
Unpack
1
Read and complete the following 8 installation steps
4
remote condensing VISION • SATELLITE-FILL
Carefully unpack and inspect the contents of your Follett icemaker.
1
Unpack
1/2"
1/2"
➊➋
➌➍
➎➏
Unpack icemaker
1. 1
5
VISION • SATELLITE-FILL remote condensing
HCC1000R/N
HCC1400R/N
5/8"(15,8mm)
3/8" (9,5mm)
NEMA
5-15
1/4"
1'
Prepare the installation site.
2
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of
icemaker in accordance with local and national codes. Outdoor installation of
low side is not recommended and will void warranty.
Electrical
• HCC1000(R/N)VS 120/60/1-6 amps
• HCC1400(R/N)VS 120/60/1-6 amps
Potable water supply
• 10-70 psi (69-483kpa)
• 45-90 F (7-32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
Drain
• The drain line from the icemaker must have at least 1/4" per foot pitch (6,4mm/0,3m)
Refrigeration lines
• 5/8" (15,8mm) diameter suction (insulated)
• 3/8" (9,5mm) liquid
Installation site requirements
2.1
6
remote condensing VISION • SATELLITE-FILL
Prepare the dispenser.
3
Dispenser preparation
Ground
24"
(610 mm)
Mount the electrical box to the side of the Vision dispenser
to establish a ground
connection.
Note: If a 4 x 4 box is mounted to a non-grounded surface, connect ground wire at an
appropriate ground.
Connect the bin signal plug on the electrical box to the bin signal cord on the bin
Insert 24" (609,6mm) of the long bin signal cable
into the hole in the back of the louvered
docking station
and secure in place with strain relief provided.
After sliding the icemaker module into the louvered docking station, disconnect the shuttle
plug
from the icemaker control box.
Complete normal installation procedure for the icemaker using the installation manual that
shipped with the icemaker.
Connect the bin signal plug
into the icemaker control box.
2.1
Bin Signal Installation
3.1
7
VISION • SATELLITE-FILL remote condensing
1" (25,4mm)
Stub Typ
3" (76mm)
1-3/4" (44,5mm)
5/8˝
low pressure
line
3" (76mm)
3/8˝
high pressure
line
Install the louvered docking assembly.
Louvered docking assembly
4
Mount louvered docking assembly
“Rough-in” the refrigerant piping
2.1
Louvered docking assembly
4.1
Mount louvered docking assembly to wall
bracket accessory
Mount louvered docking assembly to
machine stand accessory
Wall bracket accessory
Machine stand accessory
8
remote condensing VISION • SATELLITE-FILL
CROSSBRACE
21" min.
(534mm
24.5" min.
(623mm)
No Lip
Top View
Access panel/
door on counter
1.75" (45mm) min.
DOCKING STATION
Position and screw louvered docking assembly to the bottom of counter inside of access
panel/door min. of 1.75" (45mm) from the front edge of the cross brace
The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
There must be no lip or edge that would hinder the icemaker from sliding in or out of the
louvered docking station
Icemaker must be installed facing forward as shown for service accessibility
Undercounter installation requirements Horizon 1000 & 1400 series
4.1
9
VISION • SATELLITE-FILL remote condensing
Transport tube
Install the ice transport tube.
5
Dispenser ice transport tube installation
5.1
Push one end of ice transport tube(s) through hole(s) provided in side of dispenser
Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located
in end of ice transport tube(s)
Verify bin thermostat capillary tube is mounted correctly
Front View
VU155
Ice tube retainer bracket
Front View
VU300
thermostat thermostat
thermostat
ice tube
retaining
bracket
ice tube
retaining
bracket
ice tube
ice tube
tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
1" (25mm)
ice tube
retaining
bracket
ice tube
ice tube
10
remote condensing VISION • SATELLITE-FILL
1/4"
1'
Hot Water
160 F (71 C)
Ice transport tube tips
Insulate entire length of ice transport tube
Secure ice transport tube
as needed to prevent dips and traps from forming.
For long tube runs see guide on page 15.
Pitch ice transport tube at least 1/4" per foot (6,4mm/.3m)
Ice transport tube must drain towards icemaker
Ice transport tube to Icemaker
Be sure tube ends are square
Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers
before making connection to ease assembly
Push ice transport tube onto icemaker nipple
Install hose clamp
Ice transport tube installation.
5.2
11
VISION • SATELLITE-FILL remote condensing
Connect utilities to louvered docking assembly.
6
External connections
Remove access panel if necessary.
Install drain line
.
The rigid drain line from the icemaker
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
Install icemaker potable water supply
Replace access panel
Water and drain
6.1
Braze supplied expandable refrigerant
lines in place
Refrigerant
6.2
12
remote condensing VISION • SATELLITE-FILL
Connect louvered docking assembly to icemaker.
7
Internal connections
Rotate and braze refrigerant lines
Refrigeration lines
7. 3
Slide icemaker into louvered docking
assembly
Insert ice transport tube all the way into
coupling and tighten nut firmly
Ice transport tube installation
7. 1
Insert potable water line into valve
Push drain line over hose barb on
back of evaporator mount
Water and drain lines
7. 2
Remove twist tie
Carefully pass plug thru opening and
plug into wall outlet
Power cord
7. 4
13
VISION • SATELLITE-FILL remote condensing
Position plate into opening and secure
with supplied screw
Power cord
7. 5
14
remote condensing VISION • SATELLITE-FILL
Front cover
Install front cover to icemaker.
8
Complete installation of condensing unit
or connection to rack system.
Install condensing unit
8.1
Slide icemaker cover over machine
ensuring that tabs on back of cover
slip under louvers on back of louvered
docking assembly
Insert and tighten two screws through
cover and into louvered docking
assembly
Install icemaker front cover
8.2
NOTICE
Icemaker MUST be sanitized prior to operation!
Consult Operation and Service Manual provided with icemaker for sanitizing instructions.
15
VISION • SATELLITE-FILL remote condensing
1/4"
1'
max. 2 ft (.6m)
Pitch ice transport tube to allow melt water to drain towards icemaker
Secure insulated ice transport tube at least every 2 ft (.6m) to prevent dips or traps
Long tube run recommendations
00159988R03
01/11
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Follett Horizon HCD1400NVS Installation Instructions Manual

Type
Installation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI