Service Manual
EFTC-140F Hot Water Combination Boiler
Advanced Heating
& Hot Water Systems
120 Braley Road, East Freetown, MA 02717 1-800-323-9651 www.htproducts.com
LP-528 REV. 8.01.14
EFTC-140F Hot water combination boiler
Service Manual
EFTC-140F
(Hot Water Combination Boiler)
•NaturalGas
(
NG
)
– Factory Default
•LiquidPropaneGas
(
LP
)
–Field-Convertible
(Refertothegasconversionmanual.)
Model
WARNING
–Donotstoreorusegasolineorotherammablevaporsandliquidsinthevicinityofthisoranyotherappliance.
–WHATTODOIFYOUSMELLGAS
 ·Donottrytolightanyappliance.
 ·Donottouchanyelectricalswitch;donotuseanyphoneinyourbuilding.
 ·Immediatelycallyourgassupplierfromaneighborsphone.Followthegassupplier’sinstructions.
 ·Ifyoucannotreachyourgassupplier,calltheredepartment.
–Installationandservicemustbeperformedbyaqualiedinstaller,serviceagencyorthegassupplier.
Iftheinformationintheseinstructionsisnotfollowedexactly,areorexplosionmayresult,
causingpropertydamage,personalinjury,ordeath.
Heat Exchanger bears the ASME “H” Stamp
LP-528 REV. 8.01.14
1
LP-528 REV. 8.01.14
2
Chapter1ProductCharacteristics
Specications 6
Dimensions 7
ComponentsDescription 8
Flow chart 9
Time chart 10
Operationowchart 11
Wiringdiagram 13
Connector function 15
Chapter2Componentsdescription
MainControlBoard 17
Temperaturesensors 18
Burner Overheat Switch 19
Waterleveldetectionsensor 20
Detectionsensor 21
Jumpedwireconnection 22
AirPressureswitch 23
CondensateBlockageAPS 24
Flowsensor 25
Ignitiontransformer 26
FlameDetectionSensor 27
Gasvalve 28
BLDCFan 29
Burnerassembly 30
FireTubeHeatexchanger 31
Condensatetrap 32
InternalDHWstoragetank 33
InternalCH/DHWcirculationpumps 34
DHWMixingValve 35
Chapter3Howtousecontrolpanel
Functionexplanation 36
Contolpanel 37
LCDSpecication 38
ControlPanelMode 38
DHWTemperatureControl 41
DHWTemperatureControl 41
CHSupplywatertemperaturecontrol 42
LP-528 REV. 8.01.14
3
Outdoortemperaturedisplay 42
Waterowrate(GPMorLPM) 43
CHReturnwatertemperature 43
FanSpeed(RPM) 44
ProgramLockmode 44
CHSupplywatertemperature 45
DHWOutletWaterTemperature 45
ExhaustGasTemperature 46
Internalstoragetankwatertemperature 46
Overheattemperaturesensor 47
Viewsupplypowertime 47
ViewBurnerOperatingTime(Unit:1hr) 48
ViewBurnerOperatingTime(X1000hr) 48
ViewIgnitioncycles(X10times) 49
ViewIgnitioncycles(X10,000times) 49
PumpConditionDisplay 50
FaultCodeHistory 51
ClearErrorCodeHistory 51
SystemReset 52
ChangeDHWFlowRateMeasurementUnit 52
InternalStoragetankPreheatingMode 53
Changemaximumoutdoortemperature 53
Changeminimumoutdoortemperature 54
Fan,MaxRPMAdjustment 54
Fan,MinRPMAdjustment 55
ResetBurnerOperatingTime 55
DeleteIgnitingCycles 56
BoostFunction 56
CH anti-cycling time 57
BurnerONtemperature 57
LP-528 REV. 8.01.14
4
Warmweathershutdown 58
MaximumCHsupplytemperature 58
MinimumCHsupplytemperature 59
MaximumDHWSetTemperature 59
CHCapacity 60
DHWHeatingCapacity 60
InternalCHprimarypumppostruntime 61
InternalCHpumpoverruntimer(ON) 61
InternalCHpumpoverruntimer(OFF) 62
InternalDHWStorageTankSetPoint 62
InternalDHWStorageTankDierential 63
DelayTime(fromDHWtoCHMode) 63
InternalCHPumpPostPurgeTimer 64
InternalCH&DHWPumpsTestMode 64
Chapter4Troubleshooting
Flame Detection 65
GasDetection 66
APS/BurnerOverheatSwitch 66
StorageDHW/ExhaustOverheat 67
Errorcode 68
ErrorCode10 71
ErrorCode11 72
ErrorCode16 73
ErrorCode20 74
ErrorCode28 75
ErrorCode29 76
ErrorCode30 77
ErrorCode32 78
ErrorCode33 79
ErrorCode35 80
LP-528 REV. 8.01.14
5
ErrorCode36 81
ErrorCode37 82
ErrorCode38 83
ErrorCode40 84
ErrorCode41 85
ErrorCode42 86
ErrorCode43 87
ErrorCode61 88
ErrorCode66 89
ErrorCode68 90
ErrorCode72 91
ErrorCode76 92
ErrorCode80 93
ErrorCode81 94
ErrorCode85 96
ErrorCode94 96
Chapter5 Replacementinstructions
BlowAssembly 97
GasValve 98
FlowSensor 99
ElectronicMixingValve 99
APS(AirPressureSwitch) 100
InterPrimaryCHCirculationPump 100
InternalDHWStorageTank 101
FlameDetectionSensor 101
Main Controller 102
IgnitionTransformer 103
Chapter6 Componentsdiagram
RepairPartsDiagram 104
Memo
108
LP-528 REV. 8.01.14
6
ModelName EFTC-140F
GasInputRate
MAX
140,000Btu/h
MIN
28,000Btu/h
AFUE
93.2%
HotWaterCapacity
35°FRise
7.1Gal
45°FRise
5.5Gal
77°FRise
3.2Gal
Installation
Indoor/Floorstandtype
FlueSystem
SealedCombustionDirectVent
VentRun
2″(50ft),3″(100ft)Schedule40PVC,CPVC,PP,SS
OriceSize
NG(Orice/Needle)
0.232″(5.9mm)
LP(Orice/Needle)
0.185″(4.7mm)
GasSupplyPressure
NG
3.5″WCto14″WC
LP
3.5″WCto14″WC
ManifoldPressure
LowFire 2″/3"VENT
NG:-0.0039″WC/-0.002″WC
High Fire 2"/3″VENT
NG:-0.374″WC/-0.216″WC
PowerSupply
MainSupply
120V60Hz/6A
Maximum
PowerConsumption
160W
IgnitionSystem
DirectElectronicIgnition/AutomaticFlameSensing
BurnerSystem
SingleOricePremixedFuelModulationMetalFiberInfrared
GasValveSystem
Air ratio valve
Minimum Flow Rate
0.5GPM
InternalPipeMaterial
Copper
Dimensions
W15.7″-H53.0″–D26.8″
ShippingWeight
250lbs.
InternalStorageTankWaterCapacity
11Gallon
BoilerHeatExchangerCapacity
4Gallons
TotalWaterCapacity
15Gallons
MainController/ControlPanel
GTX-920C/P-920C_CB-HTP
CHPressure
Min15~Max30PSI
DHWPressure
Max150PSI
ConnectionSizes
DHWInlet/
Hot Water Outlet
3/4″NPT
CHSupply/Return
1″NPT
GasInlet
1/2″NPT(1/2x3/4BellCouplingProvidedtoUpsizeGasLine)
Materials
Cabinet
ColdRolledCarbonSteel
HeatExchanger
PrimaryHeatExchanger:StainlessSteel
SubHeatExchanger:StainlessSteel
SafetyDevices
FlameRod,OverheatCutODevice,GasValveOperationDetector,
ExhaustTemperatureHighLimitSensor,WaterTemperatureHighLimit
Sensor
Chapter1ProductCharacteristics
■
Specication
LP-528 REV. 8.01.14
7
Description Diameter
A GasConnectionAdapter
1/2″NPT(1/2x3/4BellCouplingProvidedtoUpsizeGasLine)
B ‘CHsupply’Adapter 1″
C ‘CHreturn’Adapter 1″
D ‘DHWoutlet’Adapter 3/4″
E ‘DHWinlet’Adapter 3/4″
F CondensateAdapter 1/2″
G DrainAdapter 1/2″
H
ExhaustVentConnection
3″
I IntakePipeConnection 3″
■Dimensions
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
8
NO NameofComponent
1
ExhaustOutletCollar
2
MainPCBBracket
3
BLDCFAN
4
AutomaticAirVent
5
FlameDetectionSensor
6
MainPCB
7
ExhaustGasPipe
8
Manual Switch
9
PowerPort
10
CHCirculationPump
11
AirPressureSensor
12
Tilt Switch
13
SubHeatExchangerAssembly
14
InternalCirculationPump
15
WaterDischargePipe&Connector
16
CondensateOutletConnector
17
CondensateCollector
18
DHWInletConnector
NO NameofComponent
19
WaterMixingvalve
20
WaterFillValve
21
DHW Outlet Connector
22
CH Return Connector
23
CHSupplyConnector
24
MainHeatingExchangerAssembly
25
ConrmationWindowFlame
26
GasInletConnector
27
IgnitionTrans
28
Igniter
29
GasValve
30
AirPressureSensor
31
AirIntakePipe
32
AirIntakeCollar
■ComponentsDescription
K1-14CCB K1-19CCB
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
9
[ Domestic Hot Water Mode ]
[ Space Heating Mode ]
■Flowchart
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
10
FAN
FAN
FAN
3s1.5s3s
120s(1st:60s+2nd60s)
3s1.5s3s 1.0s10s1.0s3s
■Ifnormalignition
■Ifameextinguishes
■Ifabnormalignition(Alarmafterthe10trial)
IGNITION
IGNITION
IGNITION
GASVALVE
GASVALVE
GASVALVE
FLAMEDETECTION
FLAMEDETECTION
FLAMEDETECTION
Chapter1ProductCharacteristics
■Timechart
LP-528 REV. 8.01.14
11
■Operationowchart
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
12
■Operationowchart
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
13
■WiringDiagram
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
14
■WiringDiagram
Chapter1ProductCharacteristics
Mixing Valve
LP-528 REV. 8.01.14
15
Connector
Descriptions
HT
SELV
no.oflocationand
type
Pinnr. BoardSilk
CN9
65001WS-12
1 - GROUND -
2 L PowerSupplyLine HT(120VAC)
3 CP1 Pump1:DHWPump HT(120V~)
4 IT Ignitor HT(120V~)
5 L(HT) Pump2:CentralHeatingPump HT(120V~)
6 GV GasValve HT(120V~)
7
-
- -
8 N PowerSupplyNeutral HT(120V~)
9-12
ACPowerCOMLine HT(120V~)
CN1
SMW250-05
1
RS-485
RS485+ SELV(5VDC)
2 RS485 - SELV(5VDC)
3 GND -
4 RS485+ SELV(5VDC)
5 RS485 - SELV(5VDC)
CN4
LWD1140-06
1
FAN
Unuse -
2 GND SELV(26VDC)
3 VDD SELV(14VDC)
4 Fanpower(startcoil) SELV(26VDC)
5 Fanpower(endcoil) SELV(26VDC)
6 Fanspeedfeedbacksignal SELV(14VDC)
CN8
SMW250-04
1
MCUISP
GND SELV(5VDC)
2 ISP/Resetport SELV(5VDC)
3 ISPTOOL0Dataport SELV(5VDC)
4 VCC SELV(5VDC)
CN11
LWD1140-16
1
HWL Unuse SELV(12V~)
8
2
LWL LowWaterLevelLeakageSensor SELV(12V~)
10
3
HD CentralHeatingDemand SELV(5V)
11
4
TH
ConnecttotheDisplay
Control(Thermostat)
SELV(14V)
12
5
APS AirPressureSwitch SELV(14V)
13
6
- NotUsed -
14
7
BL BurnerLimit SELV(14V)
15
8
HL CondensateBlock SELV(14V)
16
■Connectorfunction
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
16
Connector
Description
HT
SELV
no.oflocationand
type
Pin
nr.
Board
Silk
CN7
LWD1140-14
1
F.S FlameDetectSensor SELV(5VDC)
8
2
OP.S Operationwatertemperaturesensor SELV(5VDC)
9
3
DH.S DHWtemperaturesensor SELV(5VDC)
10
4
I.S
Returenwatertemperaturesensor SELV(5VDC)
11
5
BG.S Exhausttemperaturesensor SELV(5VDC)
12
6
ST.S Storagewatertemperaturesensor SELV(5VDC)
13
7
SP.S CHOverheattemperaturesensor SELV(5VDC)
14
CN14
SMW250-09
1
IWM
GND SELV(14VDC)
2 IWMSteppermotorposition SELV(14VDC)
3 VDD SELV(14VDC)
4 IWMSteppermotorcoilXphase SELV(14VDC)
5 IWMSteppermotorcoilYphase SELV(14VDC)
6 VDD SELV(14VDC)
7 IWMSteppermotorcoil/Xphase SELV(14VDC)
8 IWMpowerIWMSteppermotorcoil/Yphase SELV(14VDC)
9 NotUsed -
CN3
SMW250-06
1
WPS
NotUsed SELV(5VDC)
2 NotUsed SELV(5VDC)
3 NotUsed SELV(5VDC)
4
FLUX1
VCC SELV(5VDC)
5 WaterFlowSensor SELV(5VDC)
6 GND SELV(5VDC)
CN5
SMW250-10
1
RPM
FANRPMCheck SELV(5VDC)
2 GND SELV(5VDC)
■Connectorfunction
Chapter1ProductCharacteristics
LP-528 REV. 8.01.14
17
Description/Part# MainControlBoard/7855P-008 CheckPoint N/A
Function Thispartcontrolsallcomponentscontainedinthecombinationboiler.
Failure Event Abnormalmaincontrolleroperation.
Eects
Whenthemaincontrollerhasabnormalcondition,componentsmaynotoperate
properly.
ErrorCode Er38,Er70
Diagonostic Checkeachconnectionand/orwiresdamageonthePCB.
Color/WireNumber N/A
Chapter2Componentsdescription
LP-528 REV. 8.01.14
18
Description/Part#
CH Supply Temperature Sensor: 7855P-031
Storage Temperature Sensor:
7855P-057
DHW Temperature Sensor:
7855P-094
Exhaust Temperature Sensor:
7855P-092
Check Point CN7
Function
The controller compares each sensor with setting temperature then goes to
safety shut down when measured temperature is over the setting temperature.
Failure Event
Sensor malfunction or overheating condition detected.
Eects
Improper temperature measurement.
ErrorCode
Er 16, Er 28, Er 30, Er 32, Er 33, Er 35
Diagonostic
①
Visibly check for breakage of wires and/or each connections
②
Check each sensor’s resistance range with a multi-meter.
Color/WireNumber
CH Water High Limit Sensor (black/purple): Connector
,
Storage Temperature Sensor (black/orange): Connector
,
③
Exhaust Temperature Sensor (black/white): Connector
,
DHW Temperature Sensor (black/yellow): Connector
,
⑤
CH Supply Temperature Sensor (black/white): Connector
,
NO Item Standard
1
Temperature –
Resistance Type
Idling Condition
Temperature(
) Resistance(k
Ω
)
0 ± 0.1
-10.99
25 ± 0.1
-3.906
85 ± 0.1
0.552 ± 3%
( )Blank is for reference measurement
2 Fixed Number (25/85) 3482.4K ± 2%
3
Fixed Number of Heat
Dissipation
2.5mW/
(Min.) (While not boiling)
4 Fixed Number of Heating
8(15)Sec (Max)(63.2% reaching time
while boiling)
5
Range of Workable
Temperature
- 4 ~ 230 º
F
②③ ⑤⑥⑦
⑧⑨⑩⑪⑫⑬⑭
CHWaterHighLimitTemperatureSensor
ExhaustTemperatureSensor
StorageTemperatureSensor
DHWTemperatureSensor
CHSupplyTemperatureSensor
CN7
Chapter2Componentsdescription