1.2 Functions of the Input Section
Number of Measurement Channels and Sampling Interval
There are two types of analog input terminals, 8 channels or 16 channels.
The sampling interval (scan interval and data storage interval) varies depending on the
number of input channels as shown in the table below.
Number of Channels Sampling Interval
8 100, 200 ,500 ms, 1 , 2, 5, 10, 20, 30 s, 1, 2, 5, 10, 20 , 30 min, or 1 h
16 200 ,500 ms, 1 , 2, 5, 10, 20, 30 s, 1, 2, 5, 10, 20 , 30 min, or 1 h
Input Type and Calculation
As shown in the table below, the available input types are analog input, which includes
DC voltage, thermocouple, and RTD, and other inputs, which consist of pulse signal (1
channel) and logic signals (2 channels). Also, addition, subtraction, multiplication, and
division between two inputs can be calculated and assigned to a calculation channel
and displayed in the same fashion as measured values. The statistics of measured
values can also be displayed.
Input/Calculation Description
DC voltage Measures a DC voltage in the range of ±100 mV to ±50 V.
Thermocouple Selectable from the following types: R, S, B, K, E, J, T, N, W, L, and U.
RTD Selectable from Pt100 and JPt100 types.
Pulse signal Displays the pulse input as number of revolutions, integrated value, or
instantaneous value.
Logic signal Displays the logic waveform by taking input voltage less than or equal
to 0.9 V to be OFF (0) and input voltage greater than or equal to 2.1 V to
be ON (1).
Arithmetic calculation When the input type is set to DC voltage, thermocouple, RTD, or pulse
input, addition, subtraction, multiplication, and division can be
performed with a measured value of another channel, and the result
displayed as the measured value of that channel.
Statistical calculation Calculates and displays the maximum, minimum, average, peak (P-P),
or rms value of the measured value.
Input Range and Measurable Range
Set the input range or type for analog inputs (DC voltage, thermocouple, and RTD) and
set the measurable range for a pulse signal digital input.
• DCvoltage
Select from the input ranges listed in the following table.
Input Range Measurable Range Maximum Display Resolution
100 mV –100.00 to 100.00 mV 10 µV
500 mV –500.0 to 500.0 mV 100 µV
1 V –1.0000 to 1.0000 V 100 µV
5 V –5.000 to 5.000 V 1 mV
10 V –10.000 to 10.000 V 1 mV
50 V –50.00 to 50.00 V 10 mV
1-5V/f.s. 1.000 to 5.000 V 1 mV
f.s.: measurable range
b
+
ch1
b
+
ch2
b
+
ch3
b
+
ch4
b
+
ch5
b
+
ch6
b
+
ch7
+
ch8
Terminal block unit (8 ch): M1273JE Terminal block unit (16 ch): M1273JF