BE09-220509

MOES BE09-220509 User manual

  • Hello! I am a chat assistant familiar with the MOES Human presence sensor ZigBee 3.0 instruction manual. This document provides details on setting up and using the sensor and its main features, which include human presence, static, micro-motion and motion detection. There are also configuration details for adjusting detection distance and sensitivity, as well as setting custom delay times. I'm here to assist you with any questions you may have about the sensor or its operation.
  • What is the detection range for human presence?
    What is the detection range for human motion and micro-motion?
    How can I adjust the sensitivity of the sensor?
    What should I do if the sensor detects someone when no one is there?
    What is the default delay time?
Common problems and precautions
Detect someone when no one there: it is recommend-
ed to set the detection distance short, high and low
sensitivity to investigate the cause and find the
interferences in the environment. Avoid the
interference by limiting the farthest detection distance
and installation method.
Cannot detect when humman present: people need to
be in the effective detection area; if sitting still, they
need the body parts with relative movement (such as
breathing movement) to be inclined or facing the
equipment and then be detected.
It is suggested that the target disappearance
confirmation time (delay time) should not be too small.
The default time is 15 seconds. If it is smaller, the
target may disappear with a certain probability due to
accidental respiratory pause, resulting in missing
report.
In the scenes with low and narrow installation height,
such as bathroom, washing room and kitchen, it is
recommended to set the detection distance smaller
than the installation height and have high and low
sensitivity.
1.
2.
3.
4.
Packing List
● Human presence sensor x1
● User manual x1
SERVICE
1.During the free warranty period, if the product breaks down during
normal use, we will offer free maintenance for the product.
2.Natural disasters/man-made equipment failures, disassembly and
repair without the permission of our company, no warranty card,
products beyond the free warranty period, etc., are not within the
scope of free warranty
3.Any commitment (oral or written) made by the third party
(including the dealer/service provider) to the user beyond the
warranty scope shall be executed by the third party
4.Please keep this warranty card to ensure your rights
5.Our company may update or change the products without notice.
Please refer to the official website for the updates.
WARRANTY CARD
RECYCLING INFORMATION
All products marked with the symbol for separate collection of
waste electrical and electronic equipment (WEEE Directive 2012/19
/ EU) must be disposed of separately from unsorted municipal
waste. To protect your health and the environment, this equipment
must be disposed of at designated collection points for electrical
Installation instruction
Select a suitable installation position on the ceiling
according to the range and shape of the area to be
tested to ensure that the detection area can be
effectively covered.
The diameter of the equipment panel is 93mm, the
rear rectangular part is 65x70mm, and a circular hole
with a diameter of 80mm can be opened on the
coiling.
a.
b.
Clamp the power and signal wires on the equipment
(clamp the wires gently, otherwise the wires are easy
to be clamped off and introduced inlo the ceiling
opening).
Clip the equipment into the ceiling hole to complete
the installation.
c.
d.
Delay time: the delay time has two parameters:
The parameter configures the confirmation time after
“largel delecled”. Configuring the best parameter
value can greatly reduce the false alarm rate. Although
the larger the value is, the more reliable it is, when the
real target appears, the equipment needs a longer
time to report that the target has been detected.
The parameter configures the confirmation time after
the “targel disappears” (the delay time generally
understood by the user). The larger the configured
parameter value, the easier it is to reduce the false
alarm rate caused by the accidental disappearance of
the target. Although the larger the value, the more
reliable it is, after the target really disappears, the
equipment needs a longer lime to report that the
target has disappeared.
3.
Use instruction
Detection distance: up to 9.5 m, default to 6 m. If the
detection distance is too far, unnecessary target
interference is easy to occur in the scane with low
installation height and narrow installation height
(secondary multiple reflection, L-shaped right angle
reflection and other effects lead to the detection of
targets that do not need to be detected or affect
parameter indicators);
Sensitivity: any number from 0 to 9 can be set. 9
represents the highest sensitivity and O represents the
lowest. The default sensitivity is 7. The smaller the
sensitivity, the greater the target micro motion or
breathing amplitude and the closer the distance can
be detected. The greater the sensitivity, if there are
weaker and wider range of interferents, it is easier to
make false alarm.
1.
2.
In order to better adapt the equipment to the scene and
environment and realize the best detection function and
performance index simultaneously, the three main
parameters of “detection distance”, “sensitivity” and
“delay time" can be adjusted:
Entering the Network Configura-
tion Mode
Power on the device1.
Long press the button until blue indicator light flash
quickly, then sensor enter network configuration state.
When network configuration, make sure the device as
close as possible to the Gateway.
Open My Home Page in TuyaSmart App, click to enter
the added gatedway, select to add sub-device. Then
follow the operation according to the App hint.
If network configuration fail, repeat to long press the
device button until blue light flash quickly. Repeat
above operation.
2.
3.
4.
5.
Press and hold
the button for 5s
12V power access
Detection area instruction
Device detection area:
presence delect diameter: 2-6 m.
motion and micro motion detecct diameter: 8-12 m.
1.
Important hint: the detectable distance is related to
many factors such as installation environment, human
volume, relative angle and micro motion / movement
speed. The above parameters are only the test results of
our testers for reference only. In different environment,
the user shall be subject to the actual measurement.
Ceiling installation
2~4m
Presence detect area diamete
Motion and micro motion detecct area diameter
Product introduction
The human presence sensor has the function of human
presence, human static, human micro motion and human
motion detection, which can detect the presence or
absence of people in the area. It can also accurately
detect the static state such as personnel sleeping. The
sensor can output sensing results through wireless (WiFi,
ZigBee, Bluetooth, 4G) or wired (RS485, RS232, dry
contact, wet contact) to provide sensing and scene
intermodal functions for IOT fields such as smart home,
smart hotel, smart office, smart elevator, security
monitoring, etc.
Distribution
indicator
Reset
button
Spring
clamp
Power
access
Information
output
Instruction Manual
Human presence sensor
Enjoy Our Smart Life
English
- 1 - - 2 - - 3 - - 4 - - 5 - - 6 -
- 8 -- 7 - - 9 - - 10 - - 11 - - 12 - - 13 -
Technical parameter
Product name
Wireless Technology
Work voltage
Work current
Work temperature
Sensitivity
Detect distance
Human presence sensor
Zigbee
DC 12V
≤70mA
-20℃ ~ +70℃
0-9 (Default 7)
0.39m (Default distance 6 m)
Delay time
Light sense
Installation mode
Product size
0~2000Lux
Ceiling
93x30
1. target detection confirmation time: 010s.
2. target disappearance delay time: 0.5s25min.
It is recommended not to be less than 15 seconds.
If too small, easy to miss.
indicates that the toxic or hazardous substance
amount contained in all homogeneous materials of a
component does not exceed that stipulated in GB/T
26572.
indicates that the toxic or hazardous substance
amount contained in at least one of the homogeneous
materials of a component exceeds that stipulated in
GB/T 26572.
○:
X :
Warranty Certificate Toxic or Hazardous
Substances or Elements of this Product
This table complies with SJ/T 11364.
Toxic or Hazardous Substances or Elements
LED
PCB
Component
name
Cover and
other
components
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
○ ○
○ ○
○ ○
X
X
Maintenance Records
Failure date Cause Of Issue Fault Content Principal
Thank you for your support and purchase at we Moes,
we are always here for your complete satisfaction, just
feel free to share your great shopping experience with
us.
If you have any other need, please do not hesitate to
contact us first, we will try to meet your demand.
MOES.Official@moessmart
@moes_smart@moes_smart
@moes_smart
www.moes.net
WENZHOU NOVA NEW ENERGY CO.,LTD
Address: Power Science and Technology Innovation Center,
NO.238, Wei 11 Road, Yueqing Economic Development Zone,
Yueqing, Zhejiang, China
Tel:+86-577-57186815
AMZLAB GmbH
Laubenhof 23, 45326 Essen
Made In China
BE09
Product Information
Product Name
Product Type
Purchase Date
Warranty Period
Dealer Information
Customer's Name
Customer Phone
Customer Address
Bitte scannen Sie den QR-Code, um das deutsche
Handbuch, das Installationsvideo und die Funktionsein-
führung zu erhalten
Escanee el código QR para obtener el manual en
español, el video de instalación y la introducción de la
función
Veuillez scanner le code QR pour obtenir le manuel en
français, la vidéo d'installation et l'introduction des
fonctions
Отсканируйте QR-код, чтобы получить руководство
на русском языке, видео по установке и описание
функций
Leia o código QR para obter o manual em português, o
vídeo de instalação e a introdução das funções
请扫描二维码获取中文的说
明书、安装视频及功能介
and electronic equipment designated by the government
or local authorities. Correct disposal and recycling will
help prevent potential negative consequences for the
environment and human health. To find out where these
collection points are and how they work, contact the
installer or your local authority.
ZigBee 3.0
/