The resideo HE150 is a humidistat designed to automatically control the humidity levels in your home. It features a digital display for precise humidity readings, and can be programmed to maintain a specific humidity level. The HE150 can be used with a variety of humidifiers, and can be wired to work with your existing HVAC system. It also has an outdoor sensor to prevent over-humidification when the outdoor air is humid. With its easy-to-use interface and reliable performance, the resideo HE150 is a great choice for maintaining a comfortable and healthy indoor environment.

The resideo HE150 is a humidistat designed to automatically control the humidity levels in your home. It features a digital display for precise humidity readings, and can be programmed to maintain a specific humidity level. The HE150 can be used with a variety of humidifiers, and can be wired to work with your existing HVAC system. It also has an outdoor sensor to prevent over-humidification when the outdoor air is humid. With its easy-to-use interface and reliable performance, the resideo HE150 is a great choice for maintaining a comfortable and healthy indoor environment.

INSTALLATION ADDENDUM
69-2576-06
Wiring Configuration
ADVANCED MODELS (HE150/HE250/HE300)
Fig. 1. Wiring HumidiPRO (H6062) to humidify only with a call for Heat or Fan.
Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent
control to program humidity calls with heat, cool, or on demand.
HumidiPRO
M35152
POWER IN
G OR W
C
AIR PROVING
DEVICE
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
1
1
2
2
LEFT
LEFT
OUTDOOR
SENSOR
C
R
U
U
S
S
M35153
FROM
HUMIDITY
CONTROL
POWER IN
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
1
1
RIGHT
LEFT
WIRING CONFIGURATION
69-2576—06 2
Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand).
Fig. 4. Wiring to force fan on and prove airflow in the duct.
M35154
G (FURNACE)
G (THERMOSTAT)
ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G.
IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION
AND ROUTE THROUGH HUMIDIFIER AS SHOWN.
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
1
1
2
POWER IN
2
R
RIGHT
RIGHT
HumidiPRO
OUTDOOR
SENSOR
C
R
U
U
S
S
ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G.
IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION
AND ROUTE THROUGH HUMIDIFIER AS SHOWN.
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
1
2
M35155
G (FURNACE)
G (THERMOSTAT)
1
POWER IN
2
R
AIR PROVING
DEVICE
LEFT
RIGHT
HumidiPRO
OUTDOOR
SENSOR
C
R
U
U
S
S
WIRING CONFIGURATION
369-2576—06
BASIC MODELS (HE100/HE200)
Fig. 5. Wiring connections on the H8908 humidistat. Fig. 6. Wiring H8908 humidistat.
Fig. 7. Wiring HumidiPRO with fan interlock.
M24734
M35804
OTHER WIRE(S)
TO HVAC/FAN
WHEN NECESSARY
HUMIDIFIER
H8908
HUM/U WIRE
HUM/U WIRE
M34570A
1
TRANSFORMER
FURNACE
FAN
MOTOR
FAN CONTROL
L1
(HOT)
L2
POWER
SUPPLY
1
2
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
24 VAC WIRING.
HUMIDIFIER
2
C
R
U
U
S
S
24V CONSTANT
REQUIRED
OUTDOOR SENSOR
WIRING CONFIGURATION
© 2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
www.resideo.com
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-2576—06 M.S. Rev. 03-21 | Printed in United States
Fig. 8. Wiring HumidiPRO with 2-speed fan motor.
Fig. 9. Wiring HumidiPRO with current sensing relay. Fig. 10. Wiring HumidiPRO with air proving device.
M34571A
1
TRANSFORMER
2-SPEED
FAN MOTOR
FAN CONTROL
L1
(HOT)
L2
POWER
SUPPLY
1
2
PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
24 VAC WIRING.
HUMIDIFIER
2
C
R
U
U
S
S
24V CONSTANT
REQUIRED
OUTDOOR SENSOR
DPST
SWITCHING
RELAY
HL
C
M34572A
1
L1
(HOT)
L2
1PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
HUMIDIFIER
C
R
U
U
S
SOUTDOOR SENSOR
CURRENT
SENSING
RELAY
CHI
LO
24V CONSTANT
REQUIRED
M34573A
1
L1
(HOT)
L2
1PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
HUMIDIFIER
C
R
U
U
S
SOUTDOOR SENSOR
AIR PRESSURE
SWITCH/SAIL
SWITCH
24V CONSTANT
REQUIRED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

resideo HE150 Installation guide

Type
Installation guide

The resideo HE150 is a humidistat designed to automatically control the humidity levels in your home. It features a digital display for precise humidity readings, and can be programmed to maintain a specific humidity level. The HE150 can be used with a variety of humidifiers, and can be wired to work with your existing HVAC system. It also has an outdoor sensor to prevent over-humidification when the outdoor air is humid. With its easy-to-use interface and reliable performance, the resideo HE150 is a great choice for maintaining a comfortable and healthy indoor environment.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI