WURM CRC-BL-EEV Product information

Type
Product information

WURM CRC-BL-EEV is a state-of-the-art cold location controller designed for top-hat rail installation. With its enhanced operating modes, it can manage up to four cold locations or two control circuits with electronic expansion valves (EEVs). The device is highly versatile and can be adapted to various refrigeration applications.

One of the key features of the CRC-BL-EEV is its intelligent fan control system. It optimizes fan operation to ensure efficient cooling while preventing compressor oscillation and extending the lifespan of your refrigeration equipment. Additionally, the thermal fan control and draining time after defrosting ensure optimal performance and prevent unnecessary energy consumption.

WURM CRC-BL-EEV is a state-of-the-art cold location controller designed for top-hat rail installation. With its enhanced operating modes, it can manage up to four cold locations or two control circuits with electronic expansion valves (EEVs). The device is highly versatile and can be adapted to various refrigeration applications.

One of the key features of the CRC-BL-EEV is its intelligent fan control system. It optimizes fan operation to ensure efficient cooling while preventing compressor oscillation and extending the lifespan of your refrigeration equipment. Additionally, the thermal fan control and draining time after defrosting ensure optimal performance and prevent unnecessary energy consumption.

Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold loca-
tions or 2 control circuits with EEV
CRC-BL-EEV_V2.4.0_PI_2021-02_DE 1
Subject to technical changes
CRC-BL-EEV
1 CRC-BL-EEV
Cold location controller for top-hat rail installation with enhanced operating modes for 4
cold locations or 2 control circuits with EEV
1.1 Front view
Fig. 1: Front view
1.2 Features
Suitable for 4 cold locations max.
Up to 2 electronic expansion valves possible via expansion module
Basic functional sequences and parameters preprogrammed by selection of cold location type
Intelligent fan control, compressor oscillation protection, fan delay
Analogue fan control with X-tra-2 module
Thermal fan control and draining time after defrosting
Suitable for electric defrost, forced air defrost, hot gas defrost and cool gas defrost
Defrost control by real-time clock with power reserve
Simple defrost synchronisation of multiple controllers (master-slave)
8 defrost times by integrated weekly timer
Digital inputs for setpoint switchover, manual defrost initiation and door contact
Option to select 3-point control
Control sensor weighting can be set separately for day operation and night operation
Support for higher baud rates on the Wurm CAN communication bus (C-BUS)
Can be locked to prevent unwanted parameter adjustment (SAC - Security Access Control)
Plain text name for each parameter on the display, language selectable
Unique parameter identification with Quicklinks
BLUELINE operation
Connection of max. 2 external displays
Plug-in screw terminals
Large data memory for temperature list
Connection to the Wurm system via C-BUS and FRIGODATA XP
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold loca-
tions or 2 control circuits with EEV
2 CRC-BL-EEV_V2.4.0_PI_2021-02_DE
Subject to technical changes
CRC-BL-EEV
1.3 Safety instructions
Writing conventions
WARNUNG
Avoid the described hazard: otherwise, electric voltage represents a danger that could lead to
fatal or serious bodily injury.
VORSICHT
Avoid the described hazard: otherwise minor or medium bodily injury or damage to property will
result.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the prod-
uct and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold.
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in the case of improper use or use
for purposes other than the intended purpose.
WARNUNG
DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant when carrying out installation, wiring or removal work.
Otherwise a mains voltage and/or external voltage may still be present even if the control voltage
is switched off. Always remove both power plugs (L and N).
The wiring of the device must be carried out only by qualified electricians.
Use only the correct tools for all work.
Check all wiring after connection.
Take note of the maximum loads on all connections.
Never expose the device to moisture, for example due to condensation or cleaning agents.
Take the device out of operation if it is faulty or damaged and is therefore compromising safe
operation.
Do not open the device.
Do not repair the device yourself. If the device requires repairs, send it in with an exact descrip-
tion of the fault.
VORSICHT
ELECTROMAGNETIC INTERFERENCE CAN CAUSE FAULTS!
Always use shielded data cables and place them far away from power lines.
Target group This manual is intended for "service technician" personnel.
Intended use The CRC-BL-EEV is a cold location controller for max. 4 cold locations
or max. 2 control circuits with EEV via X-tra module.
Wurm Infocenter paperless info
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold loca-
tions or 2 control circuits with EEV
CRC-BL-EEV_V2.4.0_PI_2021-02_DE 3
Subject to technical changes
CRC-BL-EEV
Version and validity of the documentation
Any versions not listed are special solutions for individual projects and are not described in detail in this document.
This document automatically ceases to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
You can find more information on our website at www.wurm.de.
1.4 Connection diagram
Fig. 2: Connection diagram
Version Date
V2.4.0
and higher
2021-02 Documentation status
Pos. Designation Function
1C-BUS interface Data communication (H = CAN high, S = shield, L = CAN
low)
2Display sockets External displays DSP002, DSP100, DSP-LCD
3Output relays K1...K4 Dependent on cold location type, floating contact,
230V~, 4(2)A
4Power supply L 230V~/50Hz
5X-tra interface Expansion module for 2 electronic
expansion valves
6Power supply N Neutral conductor
7Digital inputs Di1...Di4 Dependent on cold location type
8Defrost bus Defrost synchronisation
9Sensor inputs S1...S4 Temperature sensor
12 13 14 15 16 17 18
11 22 23 24 25 26 27 28 29
21
38 37 36 35 34 33 32 31
39
4321
12 13 14 15 16 17 18
11 22 23 24 25 26 27 28 29
21
38 37 36 35 34 33 32 31
39
CRC-BL-EEV
Frigoentry Blueline
2sec.
74451213
d
c
13
6
8
4
7
9
2
S2
S3
S4
S1
GND
Di2
Sync.
Di3
N
Di1
Di4
L
K1
K2
K3
K4
DSP1
DSP2
H
5
0V
S
L
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold loca-
tions or 2 control circuits with EEV
4 CRC-BL-EEV_V2.4.0_PI_2021-02_DE
Subject to technical changes
CRC-BL-EEV
1.5 Installing the device
This device is designed for top-hat rail installation. The housing has standard DIN 43880 dimensions
and is also suitable for operation in fuse boxes and distribution cabinets.
The device can be positioned immediately adjacent to another device without gaps.
WARNUNG
DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant before installing. Otherwise, mains voltage and/or exter-
nal voltage may still be present, even if the control voltage is switched off. Always remove both
power plugs (L and N).
The entire plant must be free of voltage.
1. (A) Place the device with the leading edge at an acute angle to the top-hat rail.
2. (B) Push the device downwards onto the top-hat rail.
The device snaps into place with the fastening safety catch (a) on the top-hat rail.
You can now connect the device.
Fig. 3: Top-hat rail installation
1.6 Technical data
Power supply 230V~, +10% / -15%, max. 8VA
Display 1 x display with plain text display
2 x green LED, C-BUS data traffic (CAN Tx, CAN Rx)
C-BUS communication 3-conductor CAN bus interface with integrated power supply, gal-
vanically isolated
Expansion module com-
munication
Interface for connecting X-tra module
Temperature sensor 4 x TRK277/7 PLUS, DGF
(T2015, T3000, TF201/TF231, K243)
Digital inputs 4 x floating
Output relay 4 x normally open contacts, 230V~, 4(2)A
Display connection 2 x socket for ready-made line to display DSP002, DSP100, DSP-
LCD
Real-time clock Battery-buffered
Monitoring system Monitoring of data memory and connected sensors
Dimensions (W x H x D) 106mm x 90mm x 58mm (DIN 43880)
Fastening Top-hat rail TH 35-15 or TH 35-7.5 (DIN EN 60715)
Ambient temperature Operation: 0...+55°C, storage: -25...+70°C
Weight About 450g
CE conformity - 2014/30/EU (EMC Directive)
- 2014/35/EU (Low Voltage Directive)
EAC conformity - TR ZU 004/2011
- TR ZU 020/2011
RoHS II
Valid from Version 2.4.0
A
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

WURM CRC-BL-EEV Product information

Type
Product information

WURM CRC-BL-EEV is a state-of-the-art cold location controller designed for top-hat rail installation. With its enhanced operating modes, it can manage up to four cold locations or two control circuits with electronic expansion valves (EEVs). The device is highly versatile and can be adapted to various refrigeration applications.

One of the key features of the CRC-BL-EEV is its intelligent fan control system. It optimizes fan operation to ensure efficient cooling while preventing compressor oscillation and extending the lifespan of your refrigeration equipment. Additionally, the thermal fan control and draining time after defrosting ensure optimal performance and prevent unnecessary energy consumption.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI