Bogen SAH5/15/30SMTB User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

Bogen SAH5/15/30SMTB is a professional-grade surface mount loudspeaker designed to deliver clear and powerful audio in a variety of applications. With its wide frequency response, high power handling, and versatile mounting options, the SAH5/15/30SMTB is ideal for use in retail stores, restaurants, offices, schools, and more. Its compact size and sleek design make it easy to integrate into any décor, while its durable construction ensures long-lasting performance.

Bogen SAH5/15/30SMTB is a professional-grade surface mount loudspeaker designed to deliver clear and powerful audio in a variety of applications. With its wide frequency response, high power handling, and versatile mounting options, the SAH5/15/30SMTB is ideal for use in retail stores, restaurants, offices, schools, and more. Its compact size and sleek design make it easy to integrate into any décor, while its durable construction ensures long-lasting performance.

54-2222-01A 1308
Specifications are subject to change without notice.
© 2013 Bogen Communications, Inc.
SPLM
DIGITAL SOUND PRESSURE
LEVEL METER
SoundLAB Software
INSTALLATION &
INSTRUCTION MANUAL
Download Software from the Bogen website:
www.bogen.com/software
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 1
Installing and Using SoundLAB Software
Installing SoundLAB Software ..........................1-4
Software Instructions ............................................5
Software Control Panel, File Menu, Option Bar
Software Command Descriptions ........................5
Software Tool Bar ..................................................6
Tool Bar Functions
PC Connection .......................................................6
System Setup .........................................................7
SPL Unit Setting.....................................................7
PC Software Setting ..............................................8
Real-Time Measurement........................................8
Measurement Bar Instructions .............................9
Import Data.............................................................9
TABLE OF CONTENTS
Minimum requirements for
connection with a PC:
• CPU: Pentium 600 MHz or higher
• One USB interface port
• Resolution of 800 x 600 (True Color)
• 8 MB available memory
• 50 MB available disk memory
• Operating system:
Microsoft Windows XP/
Windows7
PC Requirements
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 2
1
Installing SoundLAB Software
You can download the SoundLAB software from the Bogen website at:
www.bogen.com/software. Install the driver file and double-click the
Setup.exe program icon to enter the program installation contact interface.
Click NEXT to continue
.
Click BROWSE to change the installation folder. Click NEXT to continue.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 3
2
Installing SoundLAB Software (contʼd)
When this interface appears on screen, click NEXT to enter next step.
Select “Create A Desktop Icon” if you want a desktop icon. Then click
NEXT to enter the next step.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 4
3
Click INSTALL to begin the installation.
Installing SoundLAB Software (contʼd)
When the interface displays, make sure to select “Setupbde” (database
access engine). If it is the first time installing the software on the PC, click
FINISH to install the database access engine. If this is not the first instal-
lation of the software on the PC, DO NOT
select “Setupbde”.
To begin using SoundLab, select “Run SoundLab”. Click FINISH to com-
plete the installation.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 5
4
Installing SoundLAB Software (contʼd)
If this is the first time installing the software on the PC, you must install the
database. When you see the screen shown below, click INSTALL to start
the installation process.
When you see the screen shown in the Figure below, click FINISH to com-
plete the installation process.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 6
5
Software Instructions
Software Control Panel
Software Command Descriptions
1. Menu Bar
2. Tool Bar
3. Status Bar
You can check the connection status of the SPLM
to the PC by looking at the on-screen Status Bar
loacted at the bottom of the screen.
Connect OK – indicates the connection is active
Disconnect – indicates the SPLM failed to connect
File Menu
Option Menu
Real-Time Data Measurement: The Measured Data
will be displayed on your computer screen
Open Measurement Data File in SoundLab format
Save Real-time Measurement Data
Download the Measurement Data
Export the Measurement Data to Excel
Printer Setting
Print Data Sheet
System Setting
Language selection of Software Contact Interface
Real-Time
Measure
Open
Save
Import Data
Export Data
Printer Setup
Print Data Sheet
System Setup
Language
COMMAND
FUNCTION
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 7
6
Software Tool Bar
PC Connection
Tool Bar Functions
1. Insert one end of the USB cable
into the USB jack on the side of
the SPLM.
2. Plug the other end of the USB
cable into the USB interface port
on the PC.
NOTE: Once the connection is made, a USB icon appears on the LCD of the SPLM indicating
a successful connection. If the icon does not appear, the connection is not complete.
When connected to the PC, the PC supplies power to the SPLM (so the
AA batteries are not necessary and will not be used when the unit is
connected to the PC). When the connection to the PC is ended, the SPLM
will turn off automatically unless batteries are in the SPLM.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 8
7
System Setup
SPL Unit Setting
Click OPTION > SYSTEM SETUP or click to enter the SYSTEM OPTION.
The default setup is “SPL Unit Setting”. Enter the company name if needed,
then click “OK” or “APPLY” to confirm the setting.
Click “SPL Unit Setting” to setup the following items: measurement range,
max. work mode, sample speed, and weight. Then click “OK” or “Apply
to confirm.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 9
8
PC Software Setting
Click “PC Software Setting” to setup the Low/High dB Alarm and the Alarm
sound ON/OFF. Then click “OK” or “Apply” to confirm.
Click OPTION > SYSTEM SETUP
Real-Time Measurement
Click Real-Time Measure in File Menu Bar in the Tool column to enter the
screen as shown below.
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 10
9
BUTTON
Start Real-Time Measurement
Stop Real-Time Measurement
Clear all the Measurement Data
Click to Store Real-Time Measurement Data,
Input file name in Popup Window,
Click to Save the Document
Print Graph
Zoom In
Zoom Out
Reset Zoom, Resume to Defaulted Value
Move Graph to Left or Right
FUNCTION
Measurement Bar Instructions
Click the Import Data in File Menu Bar or Import Data Button on Tool
Column to display the following screen:
Click “Import” to import the data stored in the SPLM to display as a graph.
Import Data
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 11
50 Spring Street, Ramsey, NJ 07446, U.S.A.
Tel. 201-934-8500 • Fax: 201-934-9832
www.bogen.com
10
54-2222-01A_SoftwareInstall2_Layout 1 8/28/13 11:28 AM Page 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Bogen SAH5/15/30SMTB User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Bogen SAH5/15/30SMTB is a professional-grade surface mount loudspeaker designed to deliver clear and powerful audio in a variety of applications. With its wide frequency response, high power handling, and versatile mounting options, the SAH5/15/30SMTB is ideal for use in retail stores, restaurants, offices, schools, and more. Its compact size and sleek design make it easy to integrate into any décor, while its durable construction ensures long-lasting performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI