Anviz VF30 Quick start guide

Type
Quick start guide

This manual is also suitable for

Place finger on the sensor surface
Place finger in the center of the sensor.
Illustration for placing fingerprint
Other Setup
Item Explanation
Factory default
setting
Any
RF+PW
RF+FP
PW+FP
Fingerprint only, Card only or ID+Password only
It requires both Card and Password verification
together
It requires both Card and Fingerprint
verification together
It requires both Password and Fingerprint verification
together
Enter the user ID first then verify the fingerprint
Any
ID+FP
15
Place finger straight and
flat on the sensor. Insure
maximum sensor coverage.
Card Access control
Front View
10-29-09
THU
14:03
09
IN
Fingerprint Access control
Front View
180mm
10-29-09
THU
14:03
09
IN
80mm
40mm
Side View
Press [M] key to enter system management menu.
(This requires the administrator authorization if there is admin
registered in the system.) Menu List:
Menu List
Operation Guide
Reader Appearance
Cancel/Power Key
Exit/Cancel the Present
Operation
Power on/Power off
State Key(Clock In)/Up
Confirm Key
Confirm Present Operation
State Key(Clock Out)/Down
Door Bell Key
Workcode Setup Key
Menu Key
Enter System Management Menu
Num. Keys
Enter Employee ID or Password
0-9
Door Alert
User
System Info
User, FP, Log, Serial,FirmVer
Enroll
Delete
Admin Setup
Admin Clear
Setup
Hardware Test
Keypad, LCD, Sensor, Flash
System
Time
Language
Net
Precision
Auto Off
Auto Update
Image Disp.
Log Setup
Log Alert
Re-Verify
Verify Mode
Group Setup
IP Address
Subnet Mask
Gateway IP
MAC Address
Workcode Scope
Dev ID
Anti-Back
Daylight Saving
Volume
Unlock
Mode
Server Port
Server IP
Enroll Card
Enroll Card
Swipe card!
008101-C
Cancel-C Sav-OK
Enroll
FP 1/2
Password/ Card
Esc-C Set-OK
Select [Card] Swipe the card Press [OK] to save
[OK]
press [OK]
(ID:000001-999999)
Enroll Fingerprint:
Place the same finger on the sensor twice in a row to enroll fingerprints.
Enroll Password:
Password length: 000000-999999
.
Enroll Card
Enroll User: Each user can register two fingerprints, one password and one RFID card.
1
Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of
two administrators to each unit.
2
Enroll
ID 008101
Esc-C Set-OK
IN
09 : 00
26
10-11-17 WED
MENU
User
Setup
USB Flash
User
Enroll
Delete
Verify Mode
[M]
Select [User]
[OK]
Select [Enroll]
[OK]
Input user ID
Enroll PWD
PWDID
******
Esc-C Set-OK
Input password
008101-P
Cancel-C Sav-OK
Press [OK] to save
PWDID
******
Confm
******
Input password again
[OK] [OK] [OK]
Enroll
FP 1/2
Password /Card
Esc-C Set-OK
Select [Password]
press [OK]
Take Off!
008101-1
Cancel-C Sav-OK
Press [OK] to save
Take Off! Place Finger #2
Enroll FP
Enroll FP
Place Finger #1
Enroll fingerprint
[OK]
Enroll
1/2
Password/Card
Esc-C Set-OK
FP
Select [FP]
press [OK]
Admin Setup
ID 008101
Esc-C Add-OK
Admin Setup
008101
No-C Yes-OK
Admin Setup
Esc-C Add-OK
Admin Setup
ID
000000
MENU
User
Setup
USB Flash
User
Admin Setup
Group Setup
Admin Clear
Select [User]
[OK]
Selelct [Admin Setup]
[OK] [OK] [OK] [OK]
Setup successfulInput Admin ID
Enroll FP
Enroll FP
Enroll FPEnroll FP
Enroll Card
Enroll PWD
Enroll PWD
Tips: Group setup is used for managing the access control privileges. Each group can
contain 4 time zones.
Explanation
G01
Item
Factory default
setting
G00
G01
G02-16
The user in Group00 can not open the door
The user in Group01 can open the door anytime
It is according to the Group & Time zone setting which
can be set through the software
Group Setup:
M→[User]→[OK]→[Group Setup]→[OK]→[OK]→
Input employee ID→[OK]→Input the group ID→[OK]→[OK].
Explanation
1
Tips: It doesn’t allow duplicate Device ID in one LAN. Otherwise, it will cause software
communication error.
Item
Factory default
setting
1-99999999
Device ID of the unit which is required in software
communication
Dev ID:
M→[Setup]→[OK]→[System]→[OK]→[Dev ID]→[OK]→
Input the device’s ID→[OK]→[C]→[OK].
Explanation
Item
Factory default
setting
Server Mode
192.168.0.218
255.255.255.0
192.168.0.1
192.168.0.7
5010
Mode
IP Address
Subnet Mask
MAC Address
Gateway IP
Server IP
Server Port
Net:
M→ [Setup]→[OK]→[System]→[OK]→[Net]→[OK]→to select [Mode/IP Address/Subnet Mask
/MAC Address/Gateway IP/Server IP/Server Port]→[OK]→Modify parameters→[C]→[OK].
Explanation
5
Item
Factory default
setting
1-15
The duration of the audible alarm to notify employees
of events. (Lunch, break, Off Duty)
No
No
The device does not generate a door open signal after
successful verification.
Unlock:
M→ [Setup]→[OK]→[System]→[OK]→[Unlock]→[OK]→No/1~15→[OK]→
[C]→[OK]. ‘No’-no delay time; The maximum delay time is 15 seconds.
Explanation
It generates the door open alarm signal if the door open
time is longer than the preset value
Disable the door open alarm
Item
Factory default
setting
1-250
Door Alert:
M→ [Setup]→[OK]→[System]→[OK]→[Door Alert]→[OK]→
to select No/1~99→[OK]→[C]→[OK]. ‘No’-no alert signal.
Tips: WorkCode indicates the work typeeasily distinguishes which attendance record
is related to which work type.
Explanation
Max 999999
Min 0
Item
Factory default
setting
0-999999 Valid scope for the Workcode
WorkCode:
M→ [Setup]→[OK]→[System]→[OK]→[WorkCode Scope]→[OK]
→Input Max→[OK]→Input Min→[OK] →[C]→[OK].
Verify Mode:
M→[User]→[OK]→[Verify Mode]→[OK]→[OK]→Input employee ID→[OK]→
Use [ /IN]/[OUT/ ] to select ‘ANY/RF+FP/PW+FP/RF+PW/ID+FP’→[OK]→[OK].
Explanation
Related Language
Item
Factory default
setting
Languages
Optional 4 languages.
Language:
M→[Setup]→[OK]→[System]→[OK]→[Language]→[OK]→
Use [ /IN]/[OUT/ ] to select ENG/FRCH/GERM/...→[OK]→[C]→[OK].
TCP/IP Server mode: Common network mode
TCP/IP Client mode: Only communicate
with the PC which has static IP
Set terminal IP address when communication
of TCP/IP, IP address
must be a static
IP address.
Subnet Mask of the LAN
Unique Physical address of the network moudle. This
setting can not be modified.
Default Gateway of the LAN
The IP address of the Sever Machine
when using Client Mode TCP/IP
communication.
It’s the Software Port number used when the
read is configured for TCP/IP communication.
V1.4
Restart
Button
1
2
3
4
3
1
2
Installation Diagram
Installation Step
Access Control Reader & Access Control Power Supply
Drill holes in the wall follow the hole position on back panel
Install and fix back panel, connect related cables
Connect back panel to front panel by flat cable
Package List
Wiring Instruction
Mark
Description
1
2
3
4
5
6
7
8
PIN
Mark
Description
1
2
3
4
5
6
7
8
PIN
Important notice: Please follow the wiring diagram as it is displayed. Damaged products due to
improper wiring are not covered by product warranty.
Accessory Package
Connector Jack
1
Reader
or
10-29-09
THU
14:03
09
IN
10-29-09
THU
14:03
09
IN
2
Instruction Package
Card
COMPACT
CD-ROM
EN CH
windows
FOR
Windows 98
Windows 2000
Windows XP
Windows Vista
Windows 7
Access control
Access Control Reader & Switching Power Supply
Access Control Reader & SC011
1
2
3
V1.4
NC
NOCOM
GND
D/M
D/S
GND
12I
DB1DB2GND R4BR4A GNDWO1WO0
NC
NO NO
NC
COM
COM
GND
D/M
D/S
Door Switch
Door Monitor
GND
GND
GND
12I
DC 12V Input
Wiegand 0 Output
Wiegand 1 Output
DB1
DB2
Door Bell 2
Door Bell 1
GND
GND
R4B
R4A
RS485A
RS485B
GND
GND
WO1
WO0
TCP/IP
Communication Port
Connection Cable
Connect the front part of device
P1
P2
The products are subject to change without notice.
NC
NOCOM
GND
D/M
D/S
GND
12I
DB1
DB2GND R4BR4A GNDWO1WO0
+12 GND GNDNO NCPUSH
+
+
+12V
GND
NC
NO
COM
GND
D/M
D/S
GND
12I
DB1DB2GND R4BR4A GNDWO1WO0
RELAY DELAY
POWER
SUPPLY
LOCK
EXIT
BUTTON
ANVIZ DEVICE
RELAY OUT
I II III
12V-I
GND
GND
NC
NO
COM
12V-O
GND
D0
D1
GND
BUT
ON OFF
PROGRAM
PROGRAM MODE - (YELLOW)
NORMAL MODE - (BLUE)
Attach access control reader
Access Control Power Supply
Power off to unlock
Door Bell
Door Sensor
Exit Button
Power on to unlock
DB1
DB2GND R4BR4A GNDWO1WO0
Door Bell
NC
NOCOM
GND
D/M
D/S
GND
12I
+12V
GND
Door Sensor
Exit Button
Power off to unlock
Switch Power Supply
Power on to unlock
Exit Button
Switch Power Supply
Power off to unlock
Power on to unlock
  • Page 1 1
  • Page 2 2

Anviz VF30 Quick start guide

Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI