  • Hello! I am an AI chatbot trained to assist you with the Ariel BT-150150 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What should I do if the jets are not working?
    Why is water leaking from the pipes?
    Why can't I use the hydro-massage function?
    How do I clean the hydro-massage equipment?
1. Turn on the power and make sure it won't surpass the electric current.
2. Make sure to fix leakage protection device, and the socket must be connected
with earth line.
3. Please don't block the water recycle net by any part of your body, if that
occurs, turn off the pump or power at once.
4. A switch for the supply of the hot/cool water must be installed, when stop to
use this product. The water supply switch and the power source switch
should be turned off.
5. Check the water level if it is 10-20 mm above the spray nozzle before you
start the pump or the pump could be damaged.
6. Dispose of this product according to the local law when it is out of use.
7. Please contact the local dealer for help if you have any problem.
Air bubble pump
Bottom light
Ozone
Speaker
input of CD frequency
Antenna
Water probe
Input of control panel
Electric box
Heater
Water pump
The related connection will not be
connected if the unit without bubble
system, heat pump, bottom light installed.
Your best choice!Your best choice!
Dear user:
Thank you very much for purchasing our sanitary ware. To enable you to use this
product safely and effectively, please read this installation and operation
manual carefully before use.
1.Please ensure that the product installed reliable electric leakage protection
device, the power plug contains earth line, and make sure it is reliable earthing.
Check the protect system of leakage protection each time before use.
2.Before turn on water pump, check if the water level over jets 10 to 20 mm or
not, make sure regular usage of water pump otherwise it will be destroy because
of water leakage.
3.Do not turn on water pump, heat pump or air bubble pump without water.
4.People with Hypertension symptom, after drink or heart disease are not
allowed to use the bathtub. Children have a bath must under adult's guidance.
5.During use please noticed that don't blocked the jets and avoiding the air
adjustment valve overflowing. Also keep the bathtub clean and don't let it
blocked by hair or mess.
6.During use, please firstly adjust the water temperature or it will be burned.
7.The outdoor spa is designed with ergonomic, rise and fall changes are quite
big so during use pay more attention of being slipped.
8.Please shut down the system when not to use.
1.Voltage: 220V 60Hz
2.Hydraulic pressure : 0.1 0.2Mpa
3.Power of the water pump :750W
4.Power of the air pump :200W
5.Power of the heat pump :1500W
6.Size: 1520 1520 690mm
(Remark:Auto heat system, air bubble pump and the bottom water light are the
options for the goods.)
3
Storage capacity:0.36m Storage capacity:79
1. The daily maintenance should be cleaned with ordinary detergent and soft
cloth. Please do not use the detergent which contains acetone or ammonia
liquid. If there marks or something like glue on the surface of bathtub, just
polish it with soft cloth dipping with gas.
2. If there are scratches on bathtub surface, please polish it with 1500#
frosted paper dipping with liquid and burnish it with toothpaste. It will be
shining again after that.
3. If there are furring on the surface of bathtub, it can be take away by mild
acid detergent, for example wipe the bathtub with lemon juice or vinegar
which be heated.
4. Do not wipe the chrome plated spare parts all the time, and do not get in
touch with chemical detergent etc. Otherwise the surface of chrome
plated will be destroyed. The product should be clean by soft cloth other
than coarse cloth.
5. To check the water pipe regularly in order to avoid troubles from crack of
water pipes or blocked inside.
6. If there are something such as hair stuck inside the jets, then just to twist
out the jets and remove it.
7. To clean hydro-massage equipment: To full fill hot water which is 40'C,
and pour 2g/L detergent, start hydro-massage function more than 5
minutes, then turn off the massage function and drain out the water. Next,
to full fill cold water and start hydro-massage function for 3 minutes, then
turn off the massage function and drain out the water, at last, to dry the
bathtub with towel.
8. Filter should be clean once a week.
9. Keep out from combustibles and goods which over 80 C to avoid fire
disaster and damage the product.
10. The bathtub should be transported carefully. Do not lay heavy things on it
and do not bump and shaking the tub. If the bathtub has not been used for a
long time, drain out the water of the bathtub and keep it in a dry and
ventilate environment. Avoid corrosive gas.
Water leaks from
the pipes.
1.seal ring is broken
2.screws doesn't lock tightly
3.pipes doesn't seal properly.
4.water pipe is broken
1.chang seal ring
2. lock the screws tightly
3. re-seal the silicone.
4. change water pipe
Control panel
doesn't work
1.Electricity line didn't connect to power source,
electricity leaking protection device cut off power.
2.power button is not working.
1.Re-connect the power source and check
the electricity leaking switch button.
2.change a new control panel
Lighting is off
No lighting
1.The bulb is broken
2. power line is disconnected.
3.control panel is broken
1.change a new bulb.
2.re-connect the circuit.
3 .maintain or change control panel
Radio is off
1.speaker is broken
2. power line is disconnected.
3.control panel is broken
1.change a new speaker
2.reconnect the circuit.
3. maintain or change control panel
Problems
Reasons
Maintenances
1. turn on the system
2. check through and remove the garbage
which is inside the pump. Switch pipe
can be removed.
3. install a new water pump
Water Jets are
not working.
1.check the system whether is on.
2.the impeller of water pump doesn't rotate
3.water pump is broken which caused by
working without water coming in.
The intensity of
hydro-massage
cannot be adjusted
1.water pump's suction has not enough power.
2.air adjustment valve is abnormal
3.jets or nozzles are blocked
1. check the water pump whether is
working normally.
2.change the air adjustment valve
3. remove things which are blocking the jets.
No power or
electricity leaking
protection device
is activated
1.Electricity leaking protection device cut off
power source when electricity line is not well
connected.
2.Power or electricity circuit have phenomenon
of electricity leaking.
1.check and reconnect the wiring system.
2.check the power source, electricity
circuit and ground line.
1.please use it at the normal situation
of voltage
2. check and change the switch
3.maintain and change the control panel
4.get rid of mess of the jets
Jets shower can
not be work
1. voltage is abnormal
2 .Switch cannot be work
3.control panel cannot be work
4. water in electromagnetism valve is be blocked
Shower
Shower chain
Earth line
690
Red pipe
hot water pipe
500
Socket
Water pump
Drain
Plug
Earth line
blue pipe
cold water pipe
560
770
TUNTUN
TUNTUN
TUNTUN
TUNTUN
Turn on the cold or hot water switch to fill water into the bathtub. Turn the cool
or hot water switch to adjust the water filling speed and water temperature.
Turn the shift switch to use shower head or faucet to fill water. Stop to fill
water when the water level is 10-20mm above the massage nozzle.
Press to turn on the bottom lights, then the symbol will be shown on
the screen. Press again to turn off the bottom lights.
After system startup,water in bathtub exceeds the head level,then press
button to start water pump.and meanwhile,waterpump symbol shall be
displayed on LCD.Repress button to stop waterpump function.
Press button to start the system and LCD with display function.At the
same time all functions will standby.
Repress button to shut down the system .
Press to start the air bubble pump , then the symbol will be
shown on the screen . The bubble jets spurt out air bubble. Press again to
turn off the bubble.
Press to start the heater, then the symbol will be shown on the
screen. The heater could keep temperature of water in the bathtub . Press
it again to turn off the heater.
Remark: The massage bathtub has installed water probe. If it is
waterless or the water lower than the top of probe, the air bubble pump,
water pump and heater will not work.
Press to start ozone disinfection, and press it again to turn off
the function. This function should be used after bath.
Press to open the radio, at the same time the symbol appears on
the screen. Press , (between 87.5MHZ to 108.0MHZ) to
search the channel, and press it again to search different channels.
Press to the turn down volume and press to turn up the
volume. The volume will be shown on the screen, and the adjustable
range is 0-40.
Press again to turn off the radio and turn on the CD. At the same
time, the symbol will appear on the screen. Press it again to turn off the
radio and CD.
Press to . Turn the drainage to let out the
water, turn off the power source and the water supply .
stop all functions
ON/OFFON/OFF
ON/OFFON/OFF
ON/OFFON/OFF
TVTV
Light
HeatHeat
Heater
Vol-Vol-
Vol+Vol+
Vol-Vol-
Vol+Vol+
FMFM
//
CDCD
O3
FMFM
//
CDCD
TVTV
Light
Vol-Vol-
Vol+Vol+
HeatHeat
TVTV
TUNTUN
TUNTUN
Vol-Vol-
Vol+Vol+
FMFM
//
CDCD
TUNTUN
TUNTUN
ON/OFFON/OFF
Heater
Light
O3
1.The remote control is waterproof and dampproof.
2.The usage of remote control and the function of
control panel is basically the same.
3.Lay the remote control with care, and don't throw it.
The related buttons has no effect if the unit
without bubble system, heat pump, bottom
light installed.
FMFM
//
CDCD
ON/OFFON/OFF
Light
O3
TUNTUN
TUNTUN
Heater
VolVol
++
VolVol
--
/