Mira Atom Installation & User Guide

Category
Sanitary ware
Type
Installation & User Guide

This manual is also suitable for

1
1393515-W2-A
Installation and User Guide
These instructions must be left with the user
Mira EV Thermostatic Bar Valve
For SPARES,
ADVICE or REPAIRS
please call us free
on 0800 001 4040
(UK only)
Affix Sticker Here
Model Name:
Product Code:
Date of Manufacture:
(Your guarantee information is included in this guide. Please keep these details
safe as you will need them when registering your product guarantee.)
2
1393515-W2-A
For domestic installations, Mira Showers guarantee the product against any defect
in materials or workmanship for a period of ve years from the date of purchase
(shower ttings for one year).
For non-domestic installations, Mira Showers guarantee the product against any
defect in materials or workmanship for a period of one year from the date of purchase.
Failure to follow the instructions provided with the shower will invalidate the
guarantee.
For Terms and Conditions refer to the 'Activating Your Free Guarantee and
Customer Service' pages.
Thank you for choosing a Mira shower. To enjoy the full potential of your new shower,
please take time to read this guide thoroughly, and keep it handy for future reference.
Products manufactured by Kohler Mira Ltd are designed to be safe, provided that
they are installed, used and maintained in good working order, in accordance with
our instructions and recommendations.
Follow all warnings, cautions and instructions contained in this guide, and on, or
inside the shower. This guide is also available in digital format from our website or
by contacting customer services.
Introduction
Guarantee
Type 2 Valves
This product has been certied as a Type 2 valve. It also complies with the Water
Supply (water ttings) regulations 1999. For further information on Type 2 Valves,
refer to the TMV2 Requirements Manual (available to view or download on our
website www.mirashowers.co.uk). The approved designation for this product is
listed in the table below.
Mira Mixer Showers covered by this guide:
Product Code Model Number Colour Type 2 Designation
H06A
Mira Atom, Mira
Coda Pro, Mira
Reex, Mira Apt,
Mira Relate, Mira
React
Chrome HP-S
H06G Mira Assist Chrome HP-S
3
1393515-W2-A
1 x Bar Valve
OR
2 x Wall Brackets 1 x Plastic Pipe Guide
2 x Concealing Plates 2 x Concealing Plates
2 x Compression Nuts 2 x Olives
2 x Wall Plugs 2 x Fixing Screws
1 x Pair of Handles
Pack Contents
1 x Component Pack, Containing:
1 x Pair of Handles
Note! Only 1 pair of handles and 1 pair of concealing plates are provided
and dier depending on product purchased.
Documentation
1 x Installation and User Guide
Guarantee Card (Back pages of Installation and User Guide)
OR
OR
1 x 6 l/min
Flow Regulator
Assist and React
Only
1 x Pair of Handles
1 x Pair of Handles
OR
4
1393515-W2-A
Design Registration: GB 001225254-0003
Patents: GB 2 407 138
Domestic
Light Commercial
Heavy Commercial
Healthcare
Design Registration and Patents
Recommended Usage
PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY:
Installing the Shower
1. Installation of the shower must be carried out in accordance with these
instructions by qualied, competent personnel. Read all instructions before
installing the shower.
2. DO NOT install the shower where it may be exposed to freezing conditions.
Ensure that any pipework that could become frozen is properly insulated.
3. DO NOT perform any unspecied modications to the shower or its accessories.
When servicing only use genuine Kohler Mira replacement parts.
4. If the shower is dismantled during installation or servicing then, upon completion,
an inspection must be made to ensure all connections are tight and that there
are no leaks.
Safety Information
WARNING ! This shower can deliver scalding temperatures. For continued
safe operation, follow all instructions, warnings and cautions contained
in this guide and on or inside the shower. Periodic maintenance may be
required to keep the product in good working order.
The function of a thermostatic mixing valve is to deliver water consistently
at a safe temperature. In keeping with every other mechanism, it cannot
be considered as functionally infallible and as such, cannot totally
replace a supervisor’s vigilance where that is necessary. Provided it is
installed, commissioned, operated and maintained within manufacturers
recommendations, the risk of failure, if not eliminated, is reduced to the
minimum achievable.
5
1393515-W2-A
Using the Shower
5. The shower must be operated and maintained in accordance with the
requirements of this guide. Make sure you fully understand how to operate
the shower before use, read all instructions and retain this guide for future
reference.
6. DO NOT switch the shower on if there is a possibility that the water in the shower
unit or ttings is frozen.
7. The shower can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use
of the appliance in a safe way and understand the hazards involved. Children
must not be allowed to play with the shower.
8. Anyone who may have diculty understanding or operating the controls of any
shower should be attended whilst showering. Particular consideration should
be given to the young, the elderly, the inrm or anyone inexperienced in the
correct operation of the controls.
9. DO NOT allow children to clean or perform any user maintenance to the shower
unit without supervision.
10. Always check the water temperature is safe before entering the shower.
11. DO NOT adjust the temperature control rapidly while using the shower.
12. Use caution when altering the water temperature while in use, always check
the temperature before continuing to shower.
13. DO NOT switch the shower o and back on while standing in the water ow.
14. DO NOT t any form of outlet ow control. Only Mira recommended outlet ttings
should be used.
15. The showerhead must be descaled regularly. Any blockage of the showerhead
or hose may aect showering performance.
16. The water supplies to this product must be isolated if the product is not to be
used for a long period of time. If the product or pipework is at risk of freezing
during this period they should also be drained of water.
17. When this product has reached the end of its serviceable life, it should be
disposed of in a safe manner, in accordance with current local authority recycling,
or waste disposal policy.
6
1393515-W2-A
For safety and comfort the thermostat will shut o the mixing valve within
2 Seconds if either supply fails (achieved only if the blend temperature has
a minimum dierential of 12°C from either supply temperature).
Thermostatic Shut-down
Temperatures
Close temperature control 20°C - 50°C
Optimum Thermostatic Control
Range
35°C to 45°C
(achieved with supplies of 15°C cold, 65°C hot and
nominally equal pressures)
Recommended Hot Supply 60°C to 65°C
Minimum Hot Water Supply Tem-
perature
55°C
(Note: The mixing valve can operate at temperatures
up to 85°C for short periods without damage.
However for safety reasons it is recommended that
the maximum hot water temperature is limited to
65°C)
Minimum Recommended
Dierential between Hot Supply
and Outlet Temperature
12°C at desired ow rates
Cold Water Range 1 - 25°C
Specications
Pressures
Maximum Static Pressure 1000 kPa (10 bar)
Maximum Maintained Pressure 500 kPa (5 bar)
Minimum Maintained Pressure
(Gas Water Heater)
100 kPa (1 bar)
(for optimum performance supplies should be
nominally equal)
Minimum Maintained Pressure
(Gravity System)
10 kPa (0.1 bar)
(0.1 bar = 1 Metre head from cold tank base to shower
handset outlet)
Plumbing Connections
Hot: Left 15mm pipework, 3/4" BSP to valve
Cold: Right 15mm pipework, 3/4" BSP to valve
Outlet: Bottom 1/2" BSP Male to exible hose
7
1393515-W2-A
Warning! This product does not allow for reversed inlets and will deliver
unstable temperatures if tted incorrectly.
Installation
General
1. Installation of the shower must be carried out in accordance with these
instructions by qualied, competent personnel.
2. The plumbing installation must comply with all national or local water regulations
and all relevant building regulations, or any particular regulation or practice
specied by the local water supply company.
3. Make sure all pressures and temperatures comply with the requirements of the
shower. See ‘Specications’. For Type 2 Valves, refer to supply conditions
given in the TMV2 Requirements Manual (this is available to view or
download from our website www.mirashowers.co.uk).
4. Full bore/non restrictive servicing valves must be tted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower.
DO NOT use a valve with a loose washer plate (jumper) as this can lead to a
build up of static pressure.
5. DO NOT apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
6. Pipework dead-legs should be kept to a minimum.
7. DO NOT install the shower unit in a position where access for maintenance is
restricted.
8. The shower must be tted to a waterproof, at and even wall surface. The
two screws and wall plugs supplied are suitable for most solid wall installations.
Alternative xing screws for panel structures are not supplied. Use bothxing
points to secure the shower, be sure to use xings appropriate for the chosen
wall structure.
9. When pipework enters the product from the rear through a hole in the wall,
provision must be made to prevent water ingress back into the wall structure.
10. Position the shower unit where the controls are at a convenient height for the
user. Position the showerhead so that the water sprays in line with the bath or
across the opening of a shower cubicle. The installation must not cause the
shower hose to be kinked during normal use.
Suitable Plumbing Installations
The Thermostatic Mixer can be installed with all systems with balanced pressures.
Mixed gravity and mains supplies are not recommended.
8
1393515-W2-A
11. The water supplies to this product should be isolated if the product is not to be
used for a long period of time. If the product or pipework is at risk of freezing
during this period they should also be drained of water.
12. The position of the shower and shower ttings must provide a minimum air
gap of 25  mm between the showerhead and the spill over level of any bath,
shower tray or basin. There must be a minimum distance of 30  mm between
the showerhead and the spill over lever of any toilet, bidet or other appliance
with a Fluid Category 5 backow risk.
Zone of
Backflow
Risk
30 mm
Minimum
Toilet or Bidet
FC5
Hand Basin
FC3
Bath or Shower
Tray FC3
Shower
Unit
25 mm
Minimum
25 mm Minimum
Note : There will be occasions when the hose retaining ring will not provide a suitable
solution for Fluid Category 3 installations. In these instances an outlet double
checkvalve must be tted, this will increase the required supply pressure typically
by 10 kPa (0.1 bar). Double checkvalves tted in the inlet supply to the appliance
cause a pressure build up, which aects the maximum static inlet pressure for the
appliance and must not be tted. For Fluid Category 5, double checkvalves are
not suitable.
9
1393515-W2-A
8 mm
25 mm
25 mm
150 mm
Wall Bracket
Fit the plastic pipe guide over the inlet
pipes. Level the pipe guide and secure
to the wall to hold in position. Leave
the guide in place and nish the wall.
Installation of the Bar Valve
Ø6 mm
Note: Connections are; Hot-Left,
Cold- Right.
10
1393515-W2-A
Install the olives and the connectors.
Tighten nger tight and then another
1/4 to 1/2 turn.
Turn on the water supply and ush the
pipework.
Attach the bar valve to the wall xings.
Install the ow handle.
Note: Fit the handles. See Instructions on the box in which the handles
are packed.
Install the temperature handle.
Note: Make sure that the sealing
washer/filter is installed in each
inlet.
11
1393515-W2-A
Commissioning
Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature under
ideal conditions at the factory, appropriate for most systems. However, site conditions
and personal preference may make it necessary to reset this temperature.
1. Turn the temperature handle anticlockwise until it stops and test that the
temperature of the water from the shower outlet is hot enough.
2. If not, depress the override button and carefully rotate the handle further. If the
water temperature is still not hot enough complete the following procedure.
3. Rotate the temperature selector handle back to the override position.
4. Remove temperature handle by pressing the override button and pulling the
handle.
Note: Make sure that the hot water temperature is at least 55°C and that
there is sucient supply.
Caution! Before testing the mixer, make sure that the hot and cold water
is owing correctly by exercising the temperature handle from hot to cold.
Install the shower ttings, refer
to the Installation Guide packed
with the product.
On some models (Assist and React) a 6 l/min
ow regulator can be tted into the outlet.
Shower Hose
Valve Body
Note: Orientate ow regulator as shown
above.
Note: The end
cap on the Assist
handles must be
removed before
pulling o.
Temperature
Handle
Override Button
End Cap
12
1393515-W2-A
5. Remove the xing screw holding on the handle attachment components using a
2.5 mm Allen key. Remove the two attachment components.
6. Temperature adjuster can be moved 3 positions in either direction, one position
equals 1˚C. Rotate adjuster anti-clockwise to increase temperature and rotate
clockwise to decrease temperature.
7. Replace the attachment components and make sure the xing screw is fully
tightened. Ret the handle.
Maximum Temperature Position
Location Pin
Factory Setting
Location Pin
Cleaning
Many household and commercial cleaners, including hand and surface cleaning
wipes contain abrasives and chemical substances that can damage plastics, plating
and printing and should not be used. These nishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Important! The showerhead must be de scaled regularly, keeping the showerhead
clean and free from lime scale will ensure that your shower and showerhead continue
to perform to their maximum. A blocked showerhead can restrict the ow rate and
may cause damage to your shower.
Cleaning
13
1393515-W2-A
Adjusting the Temperature
The temperature is controlled by rotating the temperature handle. For safety reasons,
the temperature is limited by an override stop. To obtain a higher temperature, press
the override button on the temperature handle and continue to rotate the handle.
Temperature
Handle
Temperature
Override Button
OFF
ON
Decrease
Temperature
Increase
Temperature
Operation
Adjusting the Flow
The ow is controlled by rotating the ow handle.
14
1393515-W2-A
Fault Diagnosis
Symptom Cause / Rectication
Water too hot or too cold Inlets reversed (hot supply to cold supply).Rework inlet pipework.
Check lters for any blockage.
Check the maximum temperature setting (If you have a combination type
boiler it may not be producing sucient hot water at the desired ow rate).
Fit a ow regulator to the shower valve outlet.
Installation conditions outside operating parameters. Refer to Specications
and Commissioning.
Poor temperature
control
Make sure that the inlet temperature dierentials are sucient, refer to
‘Specications’.
If tted to a combi boiler ensure there is sucient pressure and ow to
deliver a constant hot water inlet supply.
Check the shower handset, hose and inlet lters for any blockage and
clean where necessary.
Fluctuating or reduced
ow
Check the shower handset, hose and lters for any blockage.
Make sure that the maintained inlet pressures are nominally balanced
and sucient. Refer to Specications.
Air lock or partial blockage in the pipework.
Water leaking from
the shower handset/
overhead
Normal for a short period after shut o.
Check that the pressures are not in excess of the specications for this
product.
There may be occasions where the overhead shower or shower handset
empties for a while after the shower has been used, this is due to changes
in ambient temperatures and is normal. It is recommended that all outlets
are therefore enclosed within the water catchment area.
If you require a Mira trained service engineer or agent, refer to ‘Customer Service’.
What to do if something goes wrong
If your product does not work correctly check that it is installed and commissioned
in accordance with our instructions. If this does not resolve the issue, contact us for
help and advice. Refer to Customer Service page for more details.
Spare Parts
A list of spares for these products are available from the Mira Website, visit website
www.mirashowers.co.uk.
15
1393515-W2-A
Mira has appointed Domestic & General Insurance PLC to provide
product registration services and protection plans to accompany
its products.
What we do with your information
At Domestic & General we want to reassure you that we use
your information both responsibly and securely to provide
you with the best possible service. Below we explain what we
do with your information and your rights to your information.
If you would like any further details you can get in touch
with us using the contact details below or visit our website
(www.domesticandgeneral.com).
Using your information
Domestic & General Insurance PLC (“we”) is the “data controller”
of your information. We process two sets of information about you,
“Personal Information” (your name, address, contact and payment
details) and the “Goods Information” you provide to register your
appliance or device (your name, address, contact and goods
details). We’ll use your information:
(i) As necessary to full our contract with you (including to recover
any amounts owing); (ii) for our legitimate interests in: undertaking
marketing (about our products and services and those of our third
party partners) by post, telephone, email and/or other electronic
messaging services; market research; customer surveys; printing
services; checking and verifying your identity and contact details;
recording your conversations for training, quality and compliance
purposes; and for analytics and proling for marketing purposes;
and (iii) where required to do so by law. We may also ask for your
consent to some uses of your information.
Sharing your information
From time to time your Personal Information and Goods Information
may also be shared with other members of the Domestic & General
Group of Companies (Domestic & General Insurance or Services
and other future members of the Group whose details we will notify
to you (“Group”), where applicable with Kohler Mira Limited which
is the subject of your protection policy and with companies acting
on our behalf or providing services to us (e.g. the companies we
use to carry out repairs, IT & mailing services, storage of paper
records and telecommunications). Kohler Mira Limited will process
your Personal Information for their legitimate business interests
(including marketing and analytics) in accordance with their privacy
policy.
Transferring your information
In exceptional cases, we may transfer your information to countries
outside the European Economic Area (including the US) which may
not have data protection laws which provide the same level of pro-
tection as provided in the UK. We have put in place Model Clauses
as an appropriate safeguard to ensure that such information is ad-
equately secured and protected and that such transfers meet the
requirements of applicable data protection law.
Marketing
We, along with other members of our Group and Kohler Mira
Limited may use your information to tell you about any oers,
products or services which may be of interest to you. We may
contact you by post, telephone, email and/or other electronic
messaging services.
To change your marketing preference, let us know by emailing
[email protected] or by writing
to us using the contact details provided below. For Kohler Mira
Limited marketing you’ll need to contact them directly using
their contact details that you’ll normally nd in their privacy
notice.
Contact Details
If you need to contact us about your information or your informa-
tion rights, or to see a copy of our Model Clauses, please wrote
to Freepost Plus RTKS-CLRA-GRYE, Data Protection Ocer,
Domestic & General, Leicester House,
17 Leicester Street, Bedworth CV12 8JP or
[email protected] and we’ll be happy to
help you.
Rights to your information
By writing to the Data Protection Ocer using the contact details
provided below, you have the right to ask us:
For a copy of the Personal Information we hold about you
For a copy of the Personal Information you provided to
us to be sent to you or a third party in a commonly used,
machine readable format
To update or correct your Personal Information to keep it
accurate
To delete your Personal Information from our records if it is
no longer needed for the original purpose; and
To restrict the processing of your Personal Information in
certain circumstances
And you may also:
Object to us processing your Personal Information, in
which case we will either agree to stop processing or
explain why we’re unable to, and
Where we rely on your consent, withdraw that consent at
any time
Please note that the above rights are not absolute and certain
exemptions apply to them. You can also make a complaint to
the Information Commissioner (www.ico.org.ukl) if you feel your
Personal Information has been mishandled.
Activate your Free* Guarantee
Thankyou for choosing Mira. By registering your product,
this will act as your proof of purchase and enable us to
provide the best possible after sales service.
REGISTER NOW visit the Mira website
guarantee page
Keeping your information
We keep your Personal Information for six years after you termi-
nate your policy so that we can deal with any claims. Your goods
information we keep for a bit longer, normally 10 years (the aver-
age life of an appliance) for health and safety. We also keep your
information to send you marketing that you might be interested in,
unless we receive a request from you to opt-out of marketing.
(You will need the Model Name, Product Code and Date of
Manufacture. This information can be found on the front page of
this guide)
* If you do not activate your guarantee proof of purchase
will be required.
www.mirashowers.co.uk/support/guarantee.htm
16
1393515-W2-A © Kohler Mira Limited, November 2019
Customer Service
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specications without notice.
14648
Guarantee
Your product has the benet of our manufacturers
guarantee which starts from date of purchase. This
guarantee only applies in the United Kingdom and
Republic of Ireland.
Within the guarantee period we will resolve defects in
materials or workmanship, free of charge, by repairing
or replacing parts or product as we may choose.
Activating Your Guarantee
Registering your guarantee is quick and simple.
To ensure your product is covered, please register
online https://www.mirashowers.co.uk/support/
guarantee-registration.
This guarantee is in addition to your statutory
rights and is subject to the following conditions :
● The guarantee applies solely to the original
installation under normal use and to the original
purchaser only. The product must be installed and
maintained in accordance with the instructions
given in this guide.
● Servicing must only be undertaken by us or our
appointed representative.
Note! If a service visit is required the product must
be fully installed and connected to services.
● Repair under this guarantee does not extend
the original expiry date. The guarantee on any
replacement parts or product ends at the original
expiry date.
● For shower ttings or consumable items we
reserve the right to supply replacement parts only.
The guarantee does not cover:
● Call out charges for non product faults (such as
damage or performance issues arising from
incorrect installation, improper use, inappropriate
cleaning, lack of maintenance, build up of
limescale, frost damage, chemical attack,
corrosion, system debris or blocked lters) or
where no fault has been found with the product.
● Water or electrical supply, waste and isolation
issues.
● Compensation for loss of use of the product or
consequential or indirect loss of any kind.
● Damage or defects caused if the product is
repaired or modied by persons not authorised by
us or our appointed representative.
● Routine maintenance or replacement parts to
comply with the requirements of the TMV2 or
TMV3 healthcare schemes.
● Accidental or wilful damage.
● Products purchased ex-showroom display.
What to do if something goes wrong
If your product does not work correctly refer to this
manual for fault diagnosis and check that it is installed
and commissioned in accordance with our instructions.
If this does not resolve the issue, contact us for help
and advice.
Helpdesk Service
Contact our Customer Services Team for product
advice, to purchase spare parts or accessories or to
set up service visit. You can contact us via phone or
e-mail - contact details below.
Please provide your model name, power rating (if
applicable) and date of purchase.
Mira Showers Website
(www.mirashowers.co.uk)
Visit our website to register your guarantee, download
user guides, diagnose faults, purchase our full range
of accessories and popular spares, or request a
service visit.
Spares and Accessories
We hold the largest stocks of genuine Mira spares and
accessories.Contact us for a price or visit our website to
purchase items from our accessory range and popular
spares. (Only available in the United Kingdom )
Service/Repairs
No one knows our products better than our nationwide
team of Service Technicians. We can carry out service
or repair work to your product both during and after
the guarantee period. (Only available in the United
Kingdom and Republic of Ireland) Ask about our xed
price service repairs.
0800 001 4040
Fax: 01242 282595
Email – Visit
www.mirashowers.co.uk/contactus
By Post: Mira Customer Services Dept, Cromwell
Road, Cheltenham, Gloucestershire GL52 5EP
To Contact Us: Eire Only
01 531 9337
E-mail:
To Contact Us: UK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Mira Atom Installation & User Guide

Category
Sanitary ware
Type
Installation & User Guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI