Anolis Calumma M MC & SC User manual

Category
Stroboscopes & disco lights
Type
User manual
Version 1
.
8
QR code for user manual
Calumma M
2
Table of contents
1. Safety instructions ...................................................................................................................................................... 3
2. Fixture exterior view ................................................................................................................................................... 5
3. Installation .................................................................................................................................................................. 5
3.1 Mounting the fixture ............................................................................................................................................ 5
3.2 Connection to mains ............................................................................................................................................. 8
3.3 Top hat installlation ............................................................................................................................................ 10
3.4 Half top hat installlation ..................................................................................................................................... 11
4. Control and connection options ............................................................................................................................... 12
4.1 DMX or DALI........................................................................................................................................................ 12
4.2 Wireless DMX...................................................................................................................................................... 13
4.3 Wireless DMX to wire DMX ................................................................................................................................ 14
4.4 Power On/Off ...................................................................................................................................................... 15
4.5 DMX or Ethernet via E-box ................................................................................................................................. 16
4.5.1 Booster box ................................................................................................................................... 22
4.5.2 Booster box installation ............................................................................................................... 24
5. Software update ....................................................................................................................................................... 26
6. Technical specifications ............................................................................................................................................ 29
7. Cleaning and maintenance ....................................................................................................................................... 37
7.1 Disposing of the product .................................................................................................................................... 37
8. ChangeLog ................................................................................................................................................................ 37
Calumma M
3
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR Calumma !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure
safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this
manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual
or any unauthorized modification to the device.
Unauthorized modification will void warranty.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
This fixture should be operated only from the type of power source indicated on the marking label. If you are not
sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before servicing or cleaning.
Make sure the power/data cable is not damaged by sharp edges.
Do not install the unit near an open flame.
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with
a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective
eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light
output.
The fixture was designed for outdoor use. This fixture must not be used for underwater installation.
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the fixture is under operation.
Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or
maintenance.
Calumma M
4
Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons
not qualified to operate the fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit,
burns, electric shock etc.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of
multimedia equipment - Immunity requirements
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia
equipment – Emission Requirements according to class B.
Contains FCC ID: 2A6PL-DMXRDMRW001
Contains IC: 29573-DMXRDMRW001
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
The [Device] wireless operation is safe and complies to RF Exposure requirements.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning for fixtures with Harsh Environment Finish (HEF):
Handle with care!
Avoid any damage to the painted surface.
Damaging the paint may result in corrosion and loss of warranty.
Calumma M
5
2. Fixture exterior view
3. Installation
3.1 Mounting the fixture
The Calumma can be fastened in any orientation on a flat, non-flammable surface by means of mounting yoke (2).
The LED module (4) can be tilted +180°/-180°. Use an Allen key 2.5 for adjusting a LED module position.
Ensure that the structure to which you are attaching the fixture is secure.
1. Transparent glass cover
2. Mounting yoke
3. Tilt adjusting lock
4. LED module with heat sink
Calumma M
6
Mounting the fixture via the pole clamp adaptor
The pole clamp adaptor serves as a fastening element for Calumma M on a pole of diameter of 76-116mm or on
the flat pole. The Calumma M has to be equipped with a modified mounting yoke (P/N 11418769 ) intended for
this way of installation.
The pole clamp adaptor set includes: 1x pole clamp adaptor, 1x rubber cable gland, 3x Allen screw M8x20, 3x flat
washer, 3x spring washer, 2x tube spacer.
1. The pole clamp adaptor can be screwed on the pole by means of two screws or fixed by means of
a steel clamping tape (max. width of tape=20mm).
If you use two screws for fastening the pole clamp adaptor on the pole, drill two holes (1) for fastening the
pole clamp adaptor on the pole. Diameter of holes depends on material of pole and used screws. Be sure
that fastening of the pole clamp adaptor is secure to keep weight of Calumma.
2. Drill the hole (2) for rubber cable gland (diameter of hole=20mm, max. thickness of pole wall= 3.2mm),
make drilled hole edges clean (without burrs) and insert the rubber gland into the hole.
Calumma M
7
3. Screw the pole clamp adaptor (4) on the pole by means of two screws (5) with spring washers or use a
steel clamping tape for fastening the pole clamp adaptor on the pole.
In case of screwing the pole clamp adaptor (7) on a flat surface (pole), two pole spacers have to be inserted
under two mounting holes of the pole clamp adaptor (on fastening screws (5)) to fill up space between
the pole and the pole clamp adaptor
4. Pass the Calumma cable (6) through mounting yoke (7), pole clamp adaptor (4) and through cable gland (2)
into the pole.
5. Screw the Calumma mounting yoke (7) on the pole clamp adaptor (4) by means of three Allen screws
M8x20 (3) with washers (Allen screw + spring washer+ flat washer). Keep correct orientation of the
fastening screws (3) as drawn on the picture – two screws (B) have to aim upwards, one screw has to be
orientated towards ground.
NOTE. Three mounting openings in the mounting yoke allow positioning of the mounting yoke in range of
0°- 360°.
Calumma M
8
3.2 Connection to mains
The unit must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The Calumma is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power
source from 120-277 Volts.
3.2.1 Junction box installation
The junction box box falls under protection class I . Therefore, every junction box
has to be connected to a mains socket outlet with a protective earthing connection.
1.Unscrew the four screws (1) from the cover (2) on the junction box to get access to the terminal block (3) and
two mounting holes of diameter of 4.6 mm (4).
2. Screw the junction box on a non-flammable flat surface.
3. Connect cables.
The cable gland M20 x 1.5 with a standard seal serves for a cable of diameter of 7-13mm, for smaller diameter of
cable (4-8mm) you have to remove the original seal from the cable gland M20x1.5 and use the enclosed reducing
seal instead of it. The reducing seal for diameter of cable 4-8mm (P/N 13051388) is enclosed in the Junction box.
Remove the end cap from the cable gland before passing the cable.
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland
before inserting it into the body of the gland.
Calumma M
9
Cable gland M20x1.5:
4. Screw the cover (2) back on the junction box.
Calumma M
10
3.3 Top hat installation
1. Unscrew the four flat-head screws M3x8 (1) from the front of the Calumma and remove the flange (2).
2. Place the top hat (3) on the Calumma and screw it by means of the four flat-head screws M3x8 (1).
Calumma M
11
3.4 Half top hat installation
1. Unscrew the four flat-head screws M3x8 (1) from the front of the Calumma and remove the flange (2).
2. Place the half top hat (3) on the Calumma and screw it by means of the four flat-head screws M3x8 (1).
Calumma M
12
4. Control and connection options
4.1 DMX or DALI
Example
DMX connection (CE)
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is used for Calumma connection and
connection among junction boxes:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data + (+)
Blue
Neutral
(N)
White
Data
(
-
)
Yellow/Green
GND
Shielding
Data ground (0V)
Up to 32 Calummas can be connected in DMX line.
NOTE: DMX line of Calummas M has to be terminated at the last fixture.
EITHER connect a 120 Ohm resistor between terminals + and - in the junction box at last fixture,
OR terminate via RDM Set the ‘Manufacturer PID’ ’Terminator active’ to ‘1’ at last fixture by means of RDM Control
Panel.
Ensure ONLY the last fixture in the line is terminated using ONE of the above methods!
Calumma M
13
DALI connection
IF the 5-cored cable SJTW 5x 14AWG (P/N 1305 3336) is used for Calumma connection and connection among
junction boxes:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data
White
Neutral
(N)
Orange
Data
Yellow/Green
GND
Up to 64 Calummas can be connected in DALI network.
4.2 Wireless DMX
Example
Note: This type of connection is available for M, L, XL versions.
DMX connection (CE)
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is used for Calumma connection:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data + (+)
Blue
Neutral
(N)
White
Data
(
-
)
Yellow/Green
GND
Shielding
Data ground (0V)
DMX connection (US)
IF the 6-cored cable SJTW 6x 14AWG, (P/N 1305 3480) is used for Calumma connection:
Core
Connection
Core
Connection
Black
Live (L)
Red
Data + (+)
White
Neutral (N)
Orange
Data
(
-
)
Yellow/Green
GND
Blue
Data ground (0V)
Calumma M
14
4.3 Wireless DMX to wire DMX
Example
Note: This type of connection must have M, L or XL versions as the first luminaire. Next luminaires in a row could
be chosen from S, M, L or XL versions.
DMX connection (CE)
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is used for Calumma connection and
connection among junction boxes:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data + (+)
Blue
Neutral
(N)
White
Data
(
-
)
Yellow/Green
GND
Shielding
Data
ground (0V)
Up to 32 Calummas M can be connected in DMX chain.
DMX connection (US)
IF the 6-cored cable SJTW 6x 14AWG, (P/N 1305 3480) is used for Calumma connection and connection among
junction boxes:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data + (+)
White
Neutral (N)
Orange
Data
(
-
)
Yellow/Green
GND
Blue
Data ground (0V)
Calumma M
15
4.4 Power On/Off
Note: This type of connection is available for single chip (SC) versions only – pure white or single colour.
Non dimmable.
Input voltage: 120-277V
Power On/Off connection (CE)
3-cored cable H07BB-F 3G 1.5 (P/N 1305 1443)
Core
Connection
Br
own
Live
(L)
Light
Blue
Neutral
(N)
Yellow/Green
GND
Power On/Off connection (US)
3-cored cable SEOOW power 3x16 AWG (P/N 13051558-1)
Core
Connection
Black
Live
(L)
White
Neutral (N)
Green
GND
Calumma M
16
4.5 DMX or Ethernet via E-box
The E-box menu allows you to switch connected Calummas to the two modes:
Standard - LED modules are switched to an internal serial connection. DMX addressing of connected LED
modules is made automatically (default DMX address = 1, changes can be done by the E-box menu or by RDM)..
Pass-Thr - (Pass through). LED modules are switched to an internal parallel connection. DMX addressing of
connected LED modules has to be done manually by means of the Robe Universal Interface (or its wireless version
Robe Universal Interface WTX) and the software RDM Manager.
Example with junction boxes
Pass Through mode is intended for this connection. Max. 32 fixtures can be connected to one LED output of the E-
Box (Star, Daisy, Lite) in this mode.
NOTE. Each DMX line of Calummas M has to be terminated at the last fixture. Please see instructions in chapter 4.1
DMX or DALI.
Calumma M
17
CE version
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is used for Calumma connection and
connection among junction boxes:
Core
Connection
Core
Connection
Black
Live
(L)
Red
Data + (+)
Blue
Neutral
(N)
White
Data
(
-
)
Yellow/Green
GND
Shielding
Data ground (0V)
US version
IF the 6-cored cable SJTW 6x 14AWG, (P/N 1305 3480) is used for Calumma connection and connection among
junction boxes:
Core
Connection
Core
Connection
Black
Live (L)
Red
Data + (+)
White
Neutral (N)
Orange
Data
(
-
)
Yellow/Green
GND
Blue
Data ground (0V)
Number of connected Calummas to one E-box output depends on a cable length, power voltage, type of Calumma
and E-box operation mode.
The tables below state max. theoretical number of Calummas connected to the one LED output of the E-box.
The tables apply for the Pass-Through mode of E-box.
Calumma
M
MC
Voltage
Cable length *
120V
190V
230V
277V
10 m
28 32 32 32
20 m
28 32 32 32
30 m
20 32 32 32
50 m
12 30 32 32
70 m
8 21 31 32
100 m
6 15 22 32
Calumma
M
SC
Voltage
Cable length *
120V
190V
230V
277V
10 m
30 32 32 32
20 m
30 32 32 32
30 m
21 32 32 32
50 m
13 32 32 32
70 m
9 23 32 32
100 m
6 16 24 32
Calumma M
18
* Cable length is a total cable length between power supply (e.g. E-box) and last connected Calumma.
Example: Total cable length=L1+L2+L3+L4+L5+L6
Calumma M
19
Example with IN/OUT cables
Standard mode is intended for this connection.
Combination of Calummas and Emineres
Calumma M
20
Connection of leader cables of the Calumma M
Input connector Output connector
(front view) (front view)
Leader Cable (CE):
Wire Power Connection Wire Data Connection
Brown Live Orange Data -
Blue Neutral Purple Data +
Yellow/Green Ground (Earth) Shielding Data ground (0V)
Fixture´s Amphenol connectors are dust and water protected according to IP 67 by mating with related Amphenol
connectors. They cannot stay disconnected outdoor.
The output connector at last fixture in the Calumma chain has to always be covered with the water-tight cap to
keep declared IP rating.
The Calumma modules with IN/OUT cables should be connected to the E-box which allows power supply of the
Calumma modules and their control.
Do not connect (disconnect) Calummas to the E-box or Booster box and each other when they are under voltage!
When you change any setting of the E-box, disconnect the E-box from power and connect it to power again
to activate changes which you have made.
The tables below state max. theoretical number of Calummas connected to the one LED output of the E-box without
Booster boxes. The following table applies for the Standard mode of E-boxes.
Calumma
M
MC
Voltage
Cable length *
120V
190V
230V
277V
10 m
28 44 54 65
20 m
28 44 54 65
30 m
20 44 54 65
50 m
12 30 43 63
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41

Anolis Calumma M MC & SC User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI