  • Hello! I've reviewed the user manual for the XCE9021 remote control, as well as the XCE9000 and XME9000 digital keypad locks. This document details how to program the remote, use it for emergency lockdowns, and understand its range and other features. I'm ready to answer any questions you have about these devices.
  • What is the purpose of the remote control?
    Can the remote control release the lock down mode?
    How do I deactivate the lock down mode?
    What is the factory setting for the remote control code?
XCE9021PROGRAMMINGANDUSERMANUAL
1
XCE9021SoftwareSpecifications
XCE9021isaremotecontroldevicetobepairedwithXCE9000orXME9000Digitalkeypadlockfor
emergencylockdown.Pressingbuttonontheremotecontrolunitwillimmediatelylockdownalldoors
associatedwiththeremotecontrolunit.
Remotecontrolemergencydeviceandemergencylockstatus:
Thepurposeoftheremotecontrolisforlockingthedoordown(lockdownmode)in
emergenciesonly.Theremotecontroldoesnotreleasethelockdownmode;itonlyinitiatesthe
lockdownmode.
Theeffectiverangeforremotecontrolis75feetinsideand25feetoutside.
WhenthedoorisinlockdownmodetheredwarningLEDwillflash3timespersecond.
InthelockdownmodeyoucanstillenterMasterCode,UserCode,andOfficeCodetounlock
thedoor,butitdoesnotreleasethelockdownmode.
EnteringtheEmergencycodewilldeactivatethelockdownmodeandstoptheLEDflashing.
Remotecontrolemergencydevicehasprogrammablecodesthatcanbesetupby8bitsDIP
Switchinthedevice.Thefactorysettingis:00000000
Doorlockcorrespondingremotecontrolcodecanbeset,inordertodistinguishbetweenthe
differentcontrolgroups.doorlockthecorrespondingremotecontrolcode,factorValue:
00,000,000
Onedoorlockcanconnectwithunlimitednumberofremotecontrollers.Oneremotecontroller
canconnectwithunlimitednumberofdoorlocks.
Whendoorlocksreceivetheremotecontrollocksignal,ifthecodeisthesame,doorlockswill
enterthelockdownmodecondition.Ifthecodeisnotthesame,doorlockswillignorethe
signal.
Program95‐Settingtheremotecontrolinnercodeintheemergencycondition
#[Master]95[theremotecontrol8bitinternalcode]●●
Forexample,settingfortheemergencyremotecontrolcodeis"11110000"
1. Enter:#123459511110000
2. Opentheremotecontrolcover,changeDIPSwitchto"11110000"
3. Reinstatetheremotecontrol,presstheemergencybuttontotestthatthesettingsarecorrect
Note:XCE9000andtheremotecontrolfactorysettingsare:"00000000"
FederalCommunicationCommissionInterferenceStatement
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferenceinaresidentialinstallation.
XCE9021PROGRAMMINGANDUSERMANUAL
2
Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.
However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthis
equipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedetermined
byturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneof
thefollowingmeasures:
.Reorientorrelocatethereceivingantenna.
.Increasetheseparationbetweentheequipmentandreceiver.
.Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris
connected.
.Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
FCCCaution:Toassurecontinuedcompliance,anychangesormodificationsnotexpresslyapprovedby
thepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethisequipment.
(Example‐useonlyshieldedinterfacecableswhenconnectingtocomputerorperipheraldevices).
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1)Thisdevicemaynotcauseharmfulinterference,and(2)Thisdevicemustacceptanyinterference
received,includinginterferencethatmaycauseundesiredoperation.
/