Philips DCM-DyNet Communication Module User manual

Type
User manual

Philips DCM-DyNet Communication Module offers a range of capabilities to enhance your home and building automation system. With its IEC Overvoltage Category III and UL924 certifications, it ensures safe and reliable operation. The module supports both 12V and 24V power supply, providing flexibility in your system design. The RJ12 ports allow for easy integration of dry contact inputs, while the RS-485 DyNet port enables communication with other DyNet devices. Additionally, the module features a 24V output for powering external devices.

Philips DCM-DyNet Communication Module offers a range of capabilities to enhance your home and building automation system. With its IEC Overvoltage Category III and UL924 certifications, it ensures safe and reliable operation. The module supports both 12V and 24V power supply, providing flexibility in your system design. The RJ12 ports allow for easy integration of dry contact inputs, while the RS-485 DyNet port enables communication with other DyNet devices. Additionally, the module features a 24V output for powering external devices.

305 mm (12.01 in)
94 mm (3.70 in)
60 mm (2.36 in)
RJ12
DMC2/
DMC4
1
SHLD
+24 V-OUT
IN
GND
GND
IN 4
GND
IN 3
IN 2
GND
IN 1
GND
D +
D –
GND
D +
D –
+ V
2xRJ12
RJ12
DMX
Rx
RS-485 DyNet
UL924
INPUT INPUTS
DRY CONTACT
BUS
12/24 V 200 mA
Installation Instructions
Instructions d’installation
Installationsanweisungen
Instrucciones de instalación
Istruzioni per l’installazione
Installatie-instructies
インストル 手 順
安装指示
Communications
Module
DCM-DyNet
IEC Overvoltage Category III
40° C (104° F)
0° C (32° F)
90%
Devices must be installed by a
qualied electrician in accordance with
all national and local electrical and
construction codes and regulations.
Les appareils doivent être installés par un
électricien diplômé conformément à tous les
codes et réglementations électriques et de
construction nationaux et locaux.
Die Geräte sind von einem qualizierten Elektriker
in Übereinstimmung mit allen geltenden
Vorschriften zu installieren.
Los dispositivos deben ser instalados por un
electricista calicado y cumpliendo todas las
normas y regulaciones, tanto nacionales como
locales, sobre instalaciones eléctricas y obras.
I dispositivi devono essere installati da un
elettricista qualicato in conformità con le norme
locali e nazionali vigenti in materia di costruzioni
edilizie e installazione di impianti elettrici.
De apparaten moeten worden aangebracht
door een gekwaliceerde elektricien en in
overeenstemming met alle nationale en
plaatselijke elektriciteits- en bouwvoorschriften.
装置付け際は資格の電気技師に依頼
国おび地域の電気おび建設に関す法令に
従 ってくだ さい 。
根据国家/地区及当地的电气与建筑规范和法规,该设
备必须由有资质的电工进行安装。
.
2
DMX 512
ON
DMX 512
OFF
DMX
TERM
2
4
3
24V
12V
DyNet
DMC2 DMC4
1 Nm
8.8 Lb-in
IEC Pollution Degree II
3
+ V
D–
D+
GND
SHLD
RJ12RJ12DMX
TERM
GND
GND
D+
D–
+12/24 V
+12/24 V
+12/24 V
+12/24 V
D-
D+
GND
GND
D–
D+
GND
RS-485 DyNetRS-485 DyNet/DMX Rx
DMX
Rx
0.5 Nm
4.4 Lb-in
2.5 mm2
12+ AWG
1
2
3
4
5
6
RS-485 DyNet
2 A
+24V
UL924
UL924
INPUT INPUTS
DRY CONTACT
GND
GND
IN4
GND
IN3
IN2
GND
IN1
5
6 i ii iii
7 A 7 B
RS-485 DyNet
DSM2
1
2
DCM-DyNet
RS-485 DyNet
DCM-DyNet
DSM4
2
1
3
4
DMC2 DMC4
10 11
12
RS-485 DyNet
DCM-DyNet
Communication Module
DCM-DyNet
Communication Module
DMC2/DMC4
DMC2/DMC4
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency NoticeThis equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged
to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the
equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an
experienced radio/TV technician for help. Any modications not approved by the manufacturer of this device could void the user’s authority to operate this device.
Installation of a home and building automation and control system shall comply with HD 60364-4-41. The temperature limits and current-carrying capacities for
the communication wires specied in HD 384.5.523 shall not be exceeded.
This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B). Cet appareil numerique de la classe B est conforme a la norme NMB-
003 du Canada: CAN ICES-3(B)/NMB-3(B).
8 9
DMC2 DMC4
AZZ 432 0821 R14
© 2021 Signify Holding. All rights reserved. Specications are subject to
change without notice. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability
for any action in reliance thereon is disclaimed. Philips and the Philips
Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other
trademarks are owned by Signify Holding or their respective owners.
www.lighting.philips.com/dynalite
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Philips DCM-DyNet Communication Module User manual

Type
User manual

Philips DCM-DyNet Communication Module offers a range of capabilities to enhance your home and building automation system. With its IEC Overvoltage Category III and UL924 certifications, it ensures safe and reliable operation. The module supports both 12V and 24V power supply, providing flexibility in your system design. The RJ12 ports allow for easy integration of dry contact inputs, while the RS-485 DyNet port enables communication with other DyNet devices. Additionally, the module features a 24V output for powering external devices.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI