SL 9000 Series
Installation
Guide
V 2.1
2.7.98
12.3.97
Solid State Logic
SL 9000 Series
Installation
Guide
V2.1
2.7.98
2.7.98
Solid State Logic
Begbroke, Oxford, England OX5 1RU • +44 (0)1865 842300
1 rue Michael Faraday, 78180 Montigny le Bretonneux, France • +33 1 34 60 46 66
Via Pirandello 17, 20099 Sesto San Giovanni, Milan, Italy • +39 2 262 24956
320 West 46th Street, New York, NY 10036, USA • + 1 212 315 1111
6255 Sunset Boulevard, Los Angeles, California 90028, USA • +1 213 463 4444
702 Brimorton Drive, Scarborough, Ontario, Canada • +1 416 431 9131
3-55-14 Sendagaya, Shibuya-Ku, Tokyo 151, Japan • +81 (0)3 5474 1144
150 South Bridge Road, #02-22 Fook Hai Building, Singapore 058727 • +65 438 2272
© 1998 by Solid State Logic Limited
A Carlton Company
All Rights Reserved under International and Pan-American Copyright Conventions
SSL Total Recall and Ultimation are Trademarks of Solid State Logic Limited
No part of this publication may be reproduced in any form or
by any means, whether mechanical or electronic, without the
written permission of Solid State Logic Ltd., Oxford, England.
As research and development is a continual process, Solid State Logic reserves the right
to change the features and specifications described herein without notice or obligation.
CONTENTS
1. Introduction 3
2. Specifications 4
SL 9000 J Console 4
SL 9000 J Processor 5
SL 9000 J Power Supplies 6
Power Dissipation for J Series Consoles 8
Environmental Specification 9
3. Installation 10
Environment 10
Physical 10
Video Sync Source 10
Processor Rear Panel 12
4. System Setup 13
Making Connections 13
Grounding 13
Power Connections 15
Video and Sync 19
Network 23
Machine Control 29
Other Serial Connections 31
Rack-to-Console Connections 35
KeyPad 37
motionworker™ 39
Breakout Panels 33
Cable and Accessory Options 40
Custom Cable Lengths 41
SL 9000 J Installation Kit 42
Suggested Rack Layout 43
5. Connector Summary 44
Typical SL 9000 J DL List 44
Console Connector Panel Layout 46
Typical PatchBay layout 47
DL Connector Circuit Arrangement 48
Ethernet 49
Machine Control Connectors 49
Serial and Expansion Port Pinouts 50
7.7.99
Contents
10.11.98
SL 9000 J Series Console Installation Guide
Please Note ...
1 Maintenance
All maintenance must be carried out by fully trained personnel.
2 Non User Adjustments
Adjustments or alterations to the equipment may affect the performance
such that safety and/or international compliance standards may not be
met. Any such adjustments must therefore only be carried out by fully
trained personnel.
3 Users
This equipment is designed solely for use by engineers and operators
competent and skilled in the use of professional audio equipment.
4 Environment
This product is a class A product intended to form an integrated
component part of a Professional Audio Recording, Mixing, Dubbing,
Film, TV/Radio Broadcast or similar Studio wherein it will perform to
specification providing that it is installed according to professional
practice. Operation of this equipment outside such a controlled
environment serves no practical purpose and such attempts may cause
malperformance.
WARNING
When installing or servicing any item of SSL equipment with power
applied, HAZARDOUS
CONDITIONS CAN EXIST when cover
panels are removed. Read the relevant section of the manual before
servicing.
These hazards include:
High Voltages
High energy stored in capacitors
High current DC power buses
Hot component surfaces
In addition to standard safety precautions, metal jewellery (watches,
bracelets, etc.) that could inadvertently contact uninsulated parts
should be removed before reaching inside powered equipment.
10.11.98
Introduction
INSTALLATION INSTRUCTIONS
Installation shall be performed by competent personnel and comply with current
national wiring regulations.
VOLTAGE ADJUSTMENT and/or correct FUSE SELECTION may be required on
individual subsystems. This should be carried out before proceeding with system
installation and wiring.
THIS EQUIPMENT MUST BE EARTHED.
Equipment is designed for connection to single phase supplies with the Neutral
conductor at earth potential - category TN - and is fitted with a protective fuse in
the Live conductor only. It is not designed for use with Phase (Live) and Neutral
connections reversed or where the Neutral conductor is not at earth potential (TT
OR IT SUPPLIES).
An EXTERNAL DISCONNECT DEVICE is required for this equipment which
must be installed according to current wiring regulations. A detachable power
cord, if fitted to this equipment, is a suitable disconnect device, otherwise an
approved disconnect switch is required whose rating is defined in the product
specification and on the equipment itself.
An EXTERNAL OVER-CURRENT PROTECTION DEVICE is required to protect
the wiring to this equipment which must be installed according to current wiring
regulations. The fusing or breaking current are defined in the product
specification. In certain countries this function is supplied by use of a fused plug.
Where equipment is intended for PERMANENT INSTALLATION, cables will be
coded with either of the following colour schemes:
Live: Brown Black
Neutral: Blue White
Earth: Yellow/Green Green
Some equipment utilises MULTIPLE POWER SOURCES. This is clearly marked
on the equipment. Finished installation must also be clearly marked to ensure
that all sources of power are removed before servicing begins.
i8
12.3.97
SL 9000 J Series Console Installation Guide
Solid State Logic
SL 9000 J
Total Studio System
Installation Guide
82S6Q9K010B
2
7.10.97
SL 9000 J Series Console Installation Guide
1. Introduction
The SL 9000 J Series console is the biggest single step forward in analogue console
design for many years.
In the SL 9000, SSL has advanced the science still further, and confidently dubs the SL
9000 as the ‘ultimate analogue console’. Sound quality is combined with an advanced
digital control system, offering greater levels of automation and project management
than any previous system. It combines all of the best sonic artefacts that analogue
circuitry can provide with the creative control that computers have brought to the
recording and mixing process. Quite simply, years of design, manufacturing and
operational expertise has been focused on providing a new range of capabilities
which every recording and mixing engineer will welcome.
The design objectives of the SL 9000 are simply stated:
To provide the lowest noise and highest sonic integrity possible
To extend the range of operational facilities available to accommodate the
evolving needs of modern audio production
Provide comprehensive automation of major console functions
Incorporate and enhance the best features of the G Series and G Plus range
Provide the optional advantages of integral digital audio/video storage and
editing
The result of this undertaking is a completely new console, but with a control surface
that is quickly familiar to regular SSL users. An entirely new automation system
provides the processing power to bring new levels of digital control.
The object of this manual is to provide purchasers of SL 9000 J Series systems with
information in the following areas:
Specifications and Physical dimensions
Items supplied
Configurations and Options available
Additional items required (both essential and non-essential)
Physical installation
Cabling requirements, lengths, restrictions, and installation
Additional requirements
3
2.7.98
Introduction
The information contained within this manual
is subject to change at any time without notice.
For technical specifications of all products, consult the Technical Specification Manual.
2. Specifications
9000 J Console
Max Height : 1113 mm
Max Width : Centre Section plus end trim: 914 mm
Each 8 channel section: 331 mm
Patchbay: 491 mm
Producers Table: 491 mm
Depth : 1395mm including trim
Weight : 600 Kg approx. (48 channel standard console)
Height adjustment : +/- 25 mm
AC Power : One IEC inlet used for console video monitor
- typical power consumption less than 100W
DC Power : Centre Section: Total Power = 400W approx.
Each 8 channel bay: Total Power = 320W approx. per bay
Connections :
AC Power One IEC inlet located under centre section.
DC Power 2 or 4 (depending on console size) Harting Han K connectors
from power supply filter unit. Max distance 15m. Supplied
with 10m cables as standard.
Analogue Audio 96-way DL connectors. Up to 32 balanced circuits per
connector.
Connectors : Actual configuration of circuits dependent on Console
Configuration. Typical configuration shown in Connector
Summary (Section 5).
Tablet (See Pages 23 and 31) Tablet Network connector on ‘under
panel’ of console. Connects to KeyPad Port 5.
KeyPads RJ45 10baseT connectors on console rear panel. Up to four
KeyPads may be connected to the console (Ports 1-4), and up
to five to the processor (Ports 1-5).
Keyboard Resides in drawer beneath tablet (no external connection).
Network RJ45 10baseT connection (KeyPad Port 6) console ‘under
panel’ to Ethernet network.
Console RS-232 port for terminal diagnostics.
4
10.10.97
SL 9000 J Series Console Installation Guide
Console to Rack Equipment Interconnection
Network : RJ45 10baseT connection from console rear panel to the 9000 J
processor main connector panel. Standard cable length is 15m.
Video Monitors: Analogue RGB and TTL sync connected by 75 Ohm coaxial
cable. RGB terminated internally at the monitor. It is not
possible to ‘feed-through’ the console monitors (see Page 19).
See Page 19 for information on Video and Sync levels.
Analogue Computer
50-way MDR/MDR cables. Number depends on console size. 1
Control : per 8 channel bay. Standard length 10m. Maximum Length 25m.
Computer Interrupt 50-way MDR/MDR cables. Number depends on console size. 1
& Enable Control : per 24 channels, plus two for centre section. Standard length
10m. Maximum Length 25m.
9000 J Processor
Height : 12U
Max Depth : 475mm (excluding cabling)
Mounting : Rack mounted shelves
Weight : 35kg approximate
Voltage : 100-120 VAC/220-240 VAC, selectable at the back panel
Power : Less than 300W continuous, 400W Max.
Cooling : Front-to-back fan assisted. Allow adequate clearance for
exhaust.
Air filter : 2 part filters mounted onto clip-on trim door. Periodic changing
is required to ensure correct airflow.
Very High Density 3M™ MDR connectors based on Centronics style of contacts, 50-
Connectors : way. These used for Processor to Console Automation control.
They are located on cards inside the processor rack.
Connections are made by routing the MDR cables through from
the rear of the processor rack to the appropriate Input card.
Cables are clamped at the rear of the processor crate.
5
13.7.99
Specifications
SL 9000 J Power Supplies
Power Supply connection information, together with a suggested rack layout, can be
found on Pages 14-17.
Audio Power Raw DC Unit
Height : 4U
Max Depth : 700mm approx. (excluding cabling)
Mounting : Rack mounted shelves
Weight : 50kg approximate
Voltage : 90 - 250 VAC, Auto-sensing
Power : Fully filled unit: 3 kW, half-filled unit: 1.8 kW.
Cooling : Front-to-back fan assisted. Allow adequate clearance for
exhaust.
Air filter : 2 part filters mounted onto clip-on trim door. Periodic changing
is required to ensure correct airflow.
Digital and Motor Power Raw DC unit
Height : 4U
Max Depth : 700mm (excluding cabling)
Mounting : Rack mounted shelves
Weight : 50kg approximate
Voltage : 90 - 250 VAC, Auto-sensing
Power : Fully filled unit: 2.5 kW, half-filled unit: 1.2 kW.
Cooling : Front-to-back fan assisted. Allow adequate clearance for
exhaust.
Air filter : 2 part filters mounted onto clip-on trim door. Periodic changing
is required to ensure correct airflow.
6
13.7.99
SL 9000 J Series Console Installation Guide
DC filter and smoothing
Height : 9U ‡
Max Depth : 700mm (excluding cabling)
Mounting : Permanently mounted in base of PSU rack.
Weight : 200kg approximate
Voltage : The filter unit is Passive
Cooling : Front-to-back fan assisted. Allow adequate clearance for
exhaust.
Air filter : 2 part filters mounted onto clip-on trim door. Periodic changing
is required to ensure correct airflow.
The DC filter unit is normally fixed into the base of the Power Supply 39U rack. If
you require alternative fixing, this must be arranged prior to start of console build.
NOTE
Due to the size of the Harting Han K connectors, ensure clear access
to the rear of the rack - a minimum clearance of 12” (305mm) is recommended.
Power Supply Supervisor
Height : 1U
Max Depth : 350mm (excluding cabling)
Mounting : Rack mounted shelves
Weight : 8kg approximate
Voltage : 100-120 VAC/220-240 VAC, selectable at the back panel
Power : 150W approx.
AC Power One IEC inlet located under centre section.
DC Power 2 or 4 (depending on console size) Harting Han K connectors
from power supply filter unit. Max distance 15m. Supplied
with 10m cables as standard.
7
2.7.98
Specifications
Power Dissipation for J Series Consoles
The figures in the table below are provided for use when calculating air conditioning
requirements in the studio.
Console Size - Power Dissipation (W) -
(Channels) Console Machine Room Total
40 2000 1200 3200
48 2320 1340 3660
56 2640 1480 4120
64 2960 1620 4580
72 3280 1760 5040
80 3600 1900 5500
88 3920 2040 5960
96 4240 2180 6420
104 4560 2320 6880
112 4880 2460 7340
120 5200 2600 7800
8
17.10.97
SL 9000 J Series Console Installation Guide
9
18.9.97
Specifications
SSL Digital Products Environmental Specification
Temperature Operating: 5 - 30 Deg. C
Non-operating: -20 - 50 Deg. C
Max. Gradient: 15 Deg. C/Hour
Relative Humidity Operating: 20 - 80 %
Non-operating: 5 - 90 %
Max. wet bulb: 29 Deg. C (non-condensing)
Vibration Operating: < 0.2 G (3 - 100Hz.)
Non-operating, power off: < 0.4 G (3 - 100Hz.)
Shock Operating: < 2 G (10mSec. Max.)
Non-operating: < 10 G (10mSec. Max.)
Altitude Operating: 0 - 3000 m
(above sea level) Non-operating: 0 - 12000 m
3. Installation
In this section you will find general instructions for the installation and connection of
the SL 9000 J console and rack. Information specific to other devices (e.g VisionTrack)
can be found in the appropriate Installation and Service manuals.
Because of the flexibility of the SL 9000 J system, which allows a great diversity of
configurations, the installation instructions are generalised by nature.
Before commencing the installation procedures, we recommend that you read
through this and the next section, paying particular attention to the
interconnection diagrams. SL 9000 J systems incorporate a large amount of
external cabling, and, if a logical rack layout is planned before installation
commences, this will lead to tidier cable runs, thus making any subsequent
fault finding or alterations a great deal easier to accomplish !
Environment
The SL 9000 J rack, together with all of the associated hardware (see diagram on Page
2), should all be located in a suitable machine room, with ambient temperature
between 10 - 24 Deg. C (50 - 75 Deg. F). Air flow through the SL 9000 J rack is from
front to rear; ensure that the ventilation grills at front and rear are not covered. Avoid:
• Dusty areas or areas subject to vibration
• Areas with strong magnetic or electric fields
• Installation near heat sources
Physical
The SL 9000 J processor dimensions are tabulated on Page 5. If mounting in a 19”
rack, the SL 9000 J processor and any other 19” rack mounting parts should be
located on supporting shelves. Ensure clear access to the rear of the rack (see page 7) - a
minimum clearance of 12” (305mm) is recommended. Dimensions for a typical 64-channel
console are shown opposite. Because of the wide variety of frame options available
(wings, mechanical extensions, producer’s table etc.) the actual footprint of your
console will undoubtedly differ.
NOTE: Do NOT attempt to remove the Filter Unit from the rack.
Additional hardware may need to be located in another 19” rack, adjacent to the SL
9000 J Power Supply Rack.
Video Sync Source
The SL 9000 J will not operate without a video sync reference input. This is used to
derive sample rate and video outputs, and is also necessary for machine control. The
unit expects to receive a Composite Sync signal input of 2 Volts ±6dB peak-to-peak,
terminated in 75 Ohm (NTSC, or PAL). A Black-and-Burst signal is not a suitable
substitute. Typical video connections are shown on Page 18.
10
13.7.99
SL 9000 J Series Console Installation Guide
11
30.9.97
Installation
735
1038
303
85
1301
143 145
299
161
976
106
552
364
247
637
707
761
70
289
100 x 50
151
86
330
101
101331
33 40 41 4817 24
331
18916
331 331
25 32
331 331
280
567
1387
718
CENTRE SECTION
MONITOR
SPLIT
POINT
|
331 331331331
49 56 57 6473 8065 72
SPLIT
POINT
|
SPLIT
POINT
|
SPLIT
POINT
|
DROP FRAME
432
1425
2805
3798
SL 9080
Typical dimensions of an 80-channel console are shown above.
(Contact SSL Project Engineering for exact specification.)
Processor Rear Panel
The drawing below shows the main features of the SL 9000 J rear panel. The BITPAD
and REMOTE ports (for various serial communication), the CONSOLE port (for
terminal connection), and eight additional ports (1-4 for serial control, 5-8 unused)
are brought out to 9-way ‘D’-type connectors.
Video and sync connections are via BNC connectors, as is the NETWORK
connection.
On the right-hand side of the panel, above the IEC mains input connector, is an
additional BNC NETWORK connection for the six RJ45 PORT connectors, which
together comprise the ethernet repeater inreface. PORT 6 is used for the console-to-
processor network connection; the remaining five are available for the connection of
RJ45 10baseT network devices, such as RIOs or KeyPad.
The cable entries on the left hand side are for the Console/Processor MDR to MDR
cables. These plug in directly to the Fader Interface Cards, accessible from the front of
the Processor Crate.
The SCSI socket is for connection to an external Bernoulli drive for import of G-
Series automation data. When not being used, a SCSI Terminator must be fitted to this
socket.
The EXPANSION connector allows user defined functions to be remotely enabled.
For further details, see Pages 32, 33, and 50.
The 9-pin POWER SUPERVISOR
socket should be connected to the
appropriate socket on the Power
Supervisor Unit. This provides
computer ground potential sensing,
and must be connected. Refer to
Pages 14-17.
The 25-pin MACHINE CONTROL
socket is the connector for parallel
controlled machines. Further details
will be found on Pages 28-29.
The 25-pin TIME CODE socket is
the connector for LTC to and from
the system. Again, further details
will be found on Pages 28-29.
The four MIDI connectors, MIDI 1-
MIDI 4 provide outputs for MIDI
time code.
12
10.10.97
SL 9000 J Series Console Installation Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Carlton Solid State Logic SL 9000 J Series Installation guide

Category
Supplementary music equipment
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI