Parameter list (by parameter number)
PARAMETER LIST
15
2
153 M463 Zero current detection time 0 to 10 s 0.01 s 0.5 s ─
154 H631
Voltage reduction selection
during stall prevention
operation
0, 1, 10, 11 1 1 ─
155 T730
RT signal function validity
condition selection
0, 10 1 0 ─
156 H501
Stall prevention operation
selection
0 to 31, 100, 101 1 0 ─
157 M430 OL signal output timer 0 to 25 s, 9999 0.1 s 0 s ─
158 M301 AM terminal function selection
1 to 3, 5 to 14, 17 to 19,
21, 22, 24, 26 to 28, 30,
32 to 34, 36, 46, 50,
52 to 54, 61, 62, 67, 70,
81 to 84, 87 to 93, 97, 98
11
97,
194
159
R450 DA1 output sign selection 0 to 2 1 0 194
160 E440
User group read
selection
0, 1, 9999 1 0 ─
161 E200
Frequency setting/key lock
operation selection
0, 1, 10, 11 1 0 ─
162 A700
Automatic restart after
instantaneous power failure
selection
0 to 3, 10 to 13 1 0 ─
163 A704 First cushion time for restart 0 to 20 s 0.1 s 0 s ─
164 A705 First cushion voltage for restart 0 to 100% 0.1% 0% ─
165 A710
Stall prevention operation level
for restart
0 to 400% 0.1% 150% ─
166 M433
Output current detection signal
retention time
0 to 10 s, 9999 0.1 s 0.1 s ─
167 M464
Output current detection
operation selection
0, 1, 10, 11 1 0 ─
168
E000
Parameter for manufacturer setting. Do not set.
E080
169
E001
E081
170 M020 Watt-hour meter clear 0, 10, 9999 1 9999 ─
171 M030 Operation hour meter clear 0, 9999 1 9999 ─
172 E441
User group registered display/
batch clear
9999, (0 to 16) 1 0 ─
173 E442 User group registration 0 to 1999, 9999 1 9999 ─
174 E443 User group clear 0 to 1999, 9999 1 9999 ─
178 T700 STF terminal function selection
0 to 13, 16 to 18, 20, 23 to
28, 32, 42 to 44, 46 to 48,
50 to 53, 60, 62, 64 to 67,
70 to 72, 74, 81, 92, 93,
100 to 109, 111 to 117,
120 to 126, 9999
160202
179 T701 STR terminal function selection
0 to 13, 16 to 18, 20, 23 to
28, 32, 42 to 44, 46 to 48,
50 to 53, 61, 62, 64 to 67,
70 to 72, 74, 81, 92, 93,
100 to 109, 111 to 117,
120 to 126, 9999
161202
180 T702 RL terminal function selection
0 to 13, 16 to 18, 20, 23 to
28, 32, 42 to 44, 46 to 48,
50 to 53, 62, 64 to 67, 70
to 72, 74, 81, 92, 93, 100
to 109, 111 to 117, 120 to
126, 9999
10 202
181 T703 RM terminal function selection 11 202
182 T704 RH terminal function selection 12 202
183 T705 RT terminal function selection 13 202
184 T706 AU terminal function selection 14 202
185 T707 JOG terminal function selection 15 202
186 T708 CS terminal function selection 16 202
187 T709 MRS terminal function selection 1
24
202
10
188 T710
STOP terminal function
selection
125202
189 T711 RES terminal function selection 162202
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM CA