Andrew HELIAX HJ11-50 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Andrew HELIAX HJ11-50 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Connectors
for HELIAX
®
HJ11-50 Coaxial Cable
Bulletin 237343
Installation Instructions
6-1/8" EIA-flange,
male
6-1/8" EIA-flange,
female
1
2
2-1/8" ± 1/8"
(54 ± 3 mm)
3/4"
Revision A
3
4
5
6
9
7 8
Remove burrs
Remove part
of insulator
Remove all
copper particles
Slide clamping ring onto cable
Tap outer conductor against
inner edge of helix ring
Screw helix ring onto
outer conductor and
against gasket. Slots
must be at cable end.
Cut slits in outer conductor
at 3/16" (5 mm) intervals
Tap outer conductor
against end of helix
ring and bend tabs
into slots in ring
Apply silicone grease to
gasket threads and screw
gasket against jacket
1/4" (6.3 mm)
11
10
12
15
14
Trim conductor tabs
that extend beyond
edge of helix ring
Screw stub 1/2"
(12.7 mm) into
inner conductor
Cut 12 V-notches
45° 1/4" (6.3 mm)
deep
Position stub to align
with outer conductor
Bend tabs over
stub slots
Bend tab into slot to
hold stub in place
Form tabs to stub
13
16
17
Andrew Corporation
10500 West 153rd Street
Orland Park, IL U.S.A. 60462
Telephone: 708/349-3300
FAX (U.S.A.): 1-800/349-5444
TELEX: 25-3897
Customer Service, 24 hours: U.S.A. • Canada • Mexico: 1-800/255-1479
U.K.: 0800 250055 • Republic of Ireland: 1 800 535358
Other Europe: +44 592 782 612
Printed in U.S.A.9/95
Copyright © 1995 by Andrew Corporation
18
19
Notice
The installation, maintenance, or removal of antenna
systems requires qualified, experienced personnel.
Andrew installation instructions are written for such
personnel. Antenna systems should be inspected once
a year by qualified personnel to verify proper installa-
tion, maintenance, and condition of equipment.
Andrew disclaims any liability or responsibility for the
results of improper installation practices.
Want Andrew to attach connectors for you? Call us.
Skilled personnel at Andrew can attach connectors for
you, quickly and economically. Every factory-made
cable assembly is 100% tested before shipment and
has a 3-year warranty. For details about this service,
contact Andrew.
Drill through 4 insulator
guide holes with 3/16"
(4.7 mm) drill for gas-
pass operation
Place flare ring on insulator
and screw stud into stub so
that pin enters stub slot
Hold insulator and tighten
stud torqued to a range of
20-45 lb
f
-ft (27.1-61 N·m)
Place 2 O-rings on helix ring and 1 O-ring on
insulator. Apply silicone grease to O-rings
and gasket and slide body into place.
Use 3 long screws, equally spaced, to pull
parts together. Add short screws then
replace long screws with short screws, and
tighten screws to 6-8 lb
f
-ft (8.1-10.8 N·m)
Male
Female
/