NO. PLCBUS-5012UK
4. And then voice indicating “Please enter house code”,
“Please enter unit code”, you can setup the address of
button S2, S3 control;
5. Finishing all the setting, voice indicating “Operation
successful” means setting is success and exit setting
status.
Setting some lamp twinkling when the call is coming:
1. Press S3 and hold for 5 seconds, entering into setting
status;
2. Entering house code (A~P), and then unit code (01-16),
according above form;
3. “Operation successful” for Setting finished, exiting setting
status.
4.
If you want cancel this function: setup P16 is ok.
Recover to original status;
If you forget the password and can not control with
Telephone controller, you can recover to original status. The
setting method is: press S1 and hold for 15 seconds, the
indicate light flickers once rapidly, it is recovered. During this
process, don’t pay attention to “entering setting status”
indicate. (Ring: 6 times enter telephone system; Password:
1-1-1).
User Code Unify:
Press S1 and hold for 5 seconds, the indicate light flickers
enter setup status, no releasing, use other PLCBUS
4034UK/4036UK send a command, the indicator light stops
flickering means it has unify the User Code from other
controller. (If hold for 15 seconds will recover to original User
Code).
Transfer between 1-Phase and 3-Phase:
Press S2 and S3 button at the same time and hold for 5
seconds, indicator light flickers once for 1-phase status; three
times is for 3-phase status.
Problem resolve:
1. Transmitting ON/OFF command, while some
receiver has no responded.
● Check whether controlled receiver is on power;
● Check whether the unit code of receiver has been set
correctly, meanwhile check whether the address code is the
same between receiver and telephone controller;
● Plug receiver and telephone controller in the same
receptacle, if the receiver can not work well, it is ok just
change a new receiver; if the telephone controller can not
work well, please don’t take apart by yourselves, contact to
2. You can not control all the receivers through
telephone controller:
● Check whether the telephone controller is on power;
● Check whether the house code of telephone controller has
been set correctly,
● Plug receiver and telephone controller in the same
receptacle, if you still can not control all the receivers, it is ok
just change a new telephone controller; if the receivers can not
3. If the telephone controller responds the call
rapidly before your telephone responder gets it.
Setting telephone controller delay responds:
15 seconds ≤
the delay time ≤ 35 seconds.
4. Interior communication system:
The interior communication system carrier wave its signal onto
the power line can interfere the telephone controller working
well. Of course, if your interior communication system has its
own special telephone line or using(RF)transmitter, such
condition will not appear.
5. Electric power interrupt:
After electric power interrupts, during the resume process,
generally, lamps and wall switches (receivers) can shut
automatically, while under the power resumed, the appliance
modules still can keep the work state before interrupting.
6. (Local) control for S2 and S3:
If S2 and S3 have no any reaction, please check whether the
beforehand set house code is correct.
coffeepot, etc.)