Creative Play CH142 Installation guide

Type
Installation guide

This manual is also suitable for

DOME MOUND TUNNEL
Installation Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 1 of 13
PARTS required
REF: CH142 - DOME MOUND TUNNEL
pg 2 of 13
x4 (HEX BOARD ‘FRAMES’)
x11 (90x90 TIMBER with HEX SLATS)
x8 (HEX BOARD ‘FRAME SUPPORTS’)
x1 (600mm internal diameter
MULTIWALL PIPE)
4.3m LENGTH SUPPLIED
To be cut at an angle ON SITE
x22 (angle cleats/brackets)
PARTS required
TOOLS required
REF: CH142 - DOME MOUND TUNNEL
pg 3 of 13
x44 (FM80 BRASS SCREWS)
x150 (25kg bags of BALLAST)
x12 (25kg bags of CEMENT)
x2 (BULK BAGS BALLAST)
Foundation Details
REF: CH142 - DOME MOUND TUNNEL
pg 4 of 13
*FOUNDATIONS NOT REQUIRED - PLEASE MARK THE AREA
DIMENSIONS
shown TO ‘FRAME’
Distances shown EDGE of SURFACING to
FRAME FOOT
Surfacing Details
REF: CH142 - DOME MOUND TUNNEL
pg 5 of 13
= MINIMUM SPACE
= SURFACE AREA
*The mound
1
2
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
Attach the FRAME SUPPORTS
to the FRAMES
Repeat to create the 4 FRAMES
pg 6 of 13
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 7 of 13
3
4
Position the MULTIWALL PIPE between the FRAMES
The FRAMES slide into the RECESS’ of the PIPE
The distance between the FRAMES will be approx 839mm
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 8 of 13
5
Build up the MOUND using the 25kg bags of ballast
NOTE:
THE HATCHED AREA shows APPROXIMATELY how the
bags (cement and ballast) should be mounded
Dimensions are taken from GROUND level in the centre
to the FRONT EDGE of the FRAME
NOTE:
BAGS can be placed in
the ‘GAPS’ in the FRAME
ENSURE:
BAGS MUST be placed
under the TUBE SECTION
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 9 of 13
6
7
Attach the ANGLE CLEATS to the outside of the FRAME
Using BRASS SCREWS
Attach the TIMBER with HEX SLATS to the angle cleats
Using BRASS SCREWS
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 10 of 13
8
9
Repeat for the remaining TIMBERS
The ‘TOP’ cleats are OFFSET
Cleat on either FRAME - circled red below
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 11 of 13
10
With the timbers attached the PIPE will need to be CUT
Dashed RED LINE shows approximate ANGLE REQUIRED
NOTE:
The angle is APPROX. 45 degrees
NOTE:
EXCESS Pipe to be cut back to the CONCRETE LAYER
Assembly Instructions
REF: CH142 - DOME MOUND TUNNEL
pg 12 of 13
11
SURFACING - the mound will then be surfaced
The surfacing will be depend on the individual project - MULCH or WETPOUR
NOTE:
The shaded black section shows the
layer of SURFACING approx. 40mm
THE MOUND MUST BE SURFACED -
this is depend on the individual project
ENSURE:
Ensure the ‘ENTRY and EXIT’ sections of
the tunnel are surfaced
Additional Drawings
REF: CH142 - DOME MOUND TUNNEL
pg 13 of 13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Creative Play CH142 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI