| Infiniti™ K 160-1998 Application Manual
Data subject to change 10.2018 | Bradford White Water Heaters
Table 3
These flow are based upon setting the unit to higher temperatures and then mixing
down using cold water after the unit, to reach these flow rates.
Input rating is based on sea level operation and need not be changed for operation
up to 2000 ft (610 m) elevation. For operation at elevations above 2000 ft (610 m),
input rating is automatically reduced at the rate of 4 percent for each 1000 ft (305 m)
above sea level.
When converted to LPG the minimum input is 17000 BTU/hr (5 kW).
With constant flow.
Can be programmed to achieve up to 140 °F (60 °C).
Requirements: Steady flows, single unit installations, up to 140 °F (60 °C).
To measure Gas Pressure, see installation manual - Measuring Gas Pressure, chapter
4.13, page 36.
Refers to activation point. Deactivation point value is 0.35GPM (1.3 l/min).
Protection against water drops.
3.3 TANKLESS WATER HEATER SPECIFICATIONS
DESCRIPTION UNIT RTG-K-160 RTG-K-199
Performance
Maximum gas input
2
BTU/hr (kW) 160,000 (46.64) 199,000 (58.3)
Minimum input
3
BTU/hr (kW) 9,000 (2.6) 9,000 (2.6)
Maximum output BTU/hr (kW) 57,608 (46.2) 1 197,010 (57.7)
Thermal e ciency (E ciency in %) % > 99% > 99%
Maximum flow rate at a 35 °F (19.4 °C) rise GPM (l/min) 9.0 (34) 11.2 (42.4)
Maximum flow rate at a 45 °F (25 °C) rise GPM (l/min) 7.0 (26.7) 8.7 (27.7.9)
Maximum flow rate at a 55 °F (30.6 °C) rise GPM (l/min) 5.8 (21.9) 7.2 (27.5)
Maximum flow rate at a 75 °F (41.7 °C) rise GPM (l/min) 4.2 (15.9) 5.2 (19.7)
Maximum flow rate at a 90 °F (50 °C) rise GPM (l/min) 3.5 (13.2) 4.4 (16.6)
Temperature Control
4
Selection range °F ( °C) 100 - 120 (38 - 49) 100 - 120 (38 - 49)
Default temperature °F ( °C) 120 (49) 120 (49)
Temperature stability °F ( °C) ± 2 (± 1) ± 2 (± 1)
Gas Requirement
Gas connection inches ¾" ¾"
Inlet gas pressure range NG / LP 7 Inch W.C. 3.5” - 10.5” / 8” - 13” 3.5" - 10.5" / 8" - 13"
Water
Top hot water connection NPT inches ¾" ¾"
Top cold water connection NPT inches ¾" ¾"
Minimum water flow GPM (l/min) 0.45 (1.7) 0.45 (1.7)
Maximum water pressure PSI (bar) 150 (10.3) 150 (10.3)
Minimum recommended water pressure PSI (bar) 18 (1.2) 18 (1.2)
Minimum well pressure PSI 30 30
Water valve material – Polymer (PPS) (Polypropylene) Polymer (PPS) (Polypropylene)
Combustion
CO level ppm ≤ 250 (measured) ≤ 250 (measured)
CO2 level (set from factory) % see installation manual see installation manual
Weight
Net weight pounds (kg) 73.2 (33.20) 77.5 (35.15)
Gross weight pounds (kg) 79.37 (36.0) 83.67 (37.95)
Electrical
Voltage V AC 120 120
Frequency Hz 60 60
Amperage (Idle) mA 40 40
Amperage (operation) A ≤ 2.7 ≤ 2.7
Water protection
9
IP X4D X4D
Venting
Venting category − IV IV
Approved vent or combustion air pipe material - United States − PP fl exible/concentric/rigid, PVC sched. 40, PVC-DWV, CPVC sched. 40, ABS-DWV sched. 40
Approved vent or combustion air pipe material - Canada − CSA or ULC certified only (ULCS636)
| Infiniti® K 160-199 Application Manual
Data subject to change 10.2019 | Bradford White Water Heaters
8