Vermont Castings Aspen C3 Wood Burning Stove Owner's manual

Category
Stoves
Type
Owner's manual
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/201 8390-950i
Installation Manual
Installation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.vermontcastings.com
Pour obtenir une traduction française de ce manuel, s’il
vous plaît contacter votre revendeur ou visitez www.
vermontcastings.com
If the information in these instructions is not
followed exactly, a re may result causing
property damage, personal injury, or death.
WARNING
!
• Donotstoreorusegasolineorotherammablevapors
and liquids in the vicinity of this or any other appliance.
• Donotoverre - If appliance or chimney connector
glows, you are over ring. Over ring will void your
warranty.
Comply with all minimum clearances to combustibles
asspecied.Failuretocomplymaycausehousere.
Installationandserviceofthisapplianceshouldbeperformedby
qualiedpersonnel.Hearth&HomeTechnologiesrecommends
HHTFactoryTrainedorNFIcertiedprofessionals.
HOT SURFACES!
Glass and other surfaces are hot
duringoperationANDcooldown.
Hot glass will cause burns.
WARNING
!
Do not touch glass until it is cooled
NEVERallowchildrentotouchglass
Keep children away
CAREFULLYSUPERVISEchildreninsameroomas
replace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other
ammablematerialsaway.
ForuseintheUnitedStatesandCanada
Aspen C3 Wood Stove
NOTICE: SAVE THESE INSTRUCTIONS
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 28390-950i
TABLE OF CONTENTS
Safety Alert Key:
DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwill result in death or serious injury.
WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcould result in death or serious injury.
CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,could result in minor or moderate injury.
NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in
property damage, bodily injury, or even death.
!
1 Important Safety Information
A. ApplianceCertication ............................................. 3
B. BTU&EciencySpecications ............................... 3
C. MobileHomeApproved(USA&Canada) ................3
D. GlassSpecications ................................................ 3
E. Non-CombustibleMaterials ..................................... 4
F. Combustible Materials ............................................. 4
G. CaliforniaSafetyInformation ................................... 4
H. Smoke,CODetectors&SafetyTips ........................4
2 Getting Started
A. Design&InstallationConsiderations ....................... 5
B. FireSafety ............................................................... 5
C. NegativePressure ................................................... 5
D. ToolsAndSuppliesNeeded ..................................... 6
E. InspectApplianceandComponents ........................6
F. InstallChecklist ........................................................ 7
3 Dimensions and Clearances
A. Appliance Dimensions ............................................. 8
B. HearthProtectionRequirements ............................. 9
C. Clearances to Combustibles .................................... 10
D. LocatingYourAppliance&Chimney ........................ 12
E. ChimneyTerminationRequirements ........................ 12
F. ChimneyLocation(2-10-3Rule) ..............................13
4 Chimney Systems
A. Venting&DraftManagement ...................................14
B. VentingComponents ..............................................15
C. ChimneySystems .................................................... 15
D. InstallingChimneyComponents .............................. 17
5 Appliance Set-Up
A. RemovingUnitFromSkid ........................................ 18
B. InstallStoveLegs .................................................... 18
C. InstallFirebrick ......................................................... 18
D. OutsideAirInstallation ............................................. 19
6 Mobile Home Installation ......................................... 20
= Contains updated information
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/203 8390-950i
A. Appliance Certication
B. BTU & Eciency Specications
1 1
Important Safety Information
MODEL: Aspen C3
LABORATORY: OMNITestLaboratories,Inc
REPORT NO. 0135WS044S/0135WS044E
TYPE: SolidFuelTypeRoomHeaters/
SpaceHeatersforUsewithSolid
Fuel
STANDARD(s): ASTME2515,ASTME2780,UL
1482-2011(2015),ULC-S627-00,
CSAB415.1
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
WARNING
!
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Installation and/or use of any component part not
approvedbyHearth&HomeTechnologies.
Operating appliance without fully assembling all
components.
• Operatingappliancewithoutlegsattached(ifsupplied
withit).
• DoNOTOverre-Ifapplianceorchimneyconnector
glows,youareoverring.
Anysuchactionthatmaycausearehazard.
C. Mobile Home Approved (USA & Canada)
This appliance is approved for mobile home installations
intheUSA&Canadawhennotinstalled in a sleeping
room and when an outside combustion air inlet is
provided.
Thestructuralintegrityofthemobilehomeoor,ceiling,
and walls must be maintained.
• Theunitmust be boltedtotheoor.This canbedone
using an appropriate fastener for the application.
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimneymustbelistedtoUL103HToralistedUL-1777
fulllengthsix”(152mm)diameterlinermustbeused.
Outsideairmustbeinstalledinamobilehomeinstallation.
D. Glass Specications
This appliance is equipped with 5mm ceramic glass.
Replaceglassonlywith5mmceramicglass.Pleasecontact
your dealer for replacement glass.
Certied to comply with 2020 US particulate emissions
standard using crib woodat1.99g/hr.,Certiedtocomply
with 2020 particulate emission standards for single burn rate
heaters. This single burn rate wood heater is not approved
forusewithauedamper.
This wood appliance needs periodic inspection and repair for
properoperation.Itisagainstfederalregulationstooperate
this wood appliance in a manner inconsistent with operating
instructions in this manual.
EPA Certication Number: 196-19
EPA Certied Emissions: 1.99g/h
*LHV Tested Eciency: 81.4%
**HHV tested Eciency: 75.2%
***EPA BTU Output: 17,500
****Peak BTU/Hour Output: 35,200
Other Important Information
Vent Size: 6Inch(152mm)
Firebox Size: 1.25 cu. ft.
Outside Air Size: 3Inch
Max. Wood Length: 18"
Ideal Wood Length: 16"
Fuel SeasonedCordwood
(20%moisture)or
compressed logs
* Weighted average LHV eciency using Douglas Fir
dimensional lumber and data collected during EPA
emissions test.
**Weighted average HHV eciency using Douglas
Fir dimensional lumber and data collected during EPA
emissions test.
***Ecienciesarebasedontestresultscalculatedusing
B415; these calculated eciencies are then used to
calculateoutputBTU’s.
****ApeakBTUoutoftheappliancecalculatedusingthe
maximumrsthourburnratefromtheHighEPATestand
theBTUcontentofcordwood(8600)timestheeciency.
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/204 8390-950i
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Forassistanceoradditionalinformation,consultaqualied
installer, service agency or your dealer.
Hearth & Home Technologies WILL NOT warranty
appliancesthatexhibitevidenceofring.Evidenceofring
includes, but is not limited to:
Warped Damper
Deteriorated refractory
Deteriorated interior components
E. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
-Steel -Plaster
-Brick -Iron
-Concrete -Tile
-Glass -Slate
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
F. Combustible Materials
Materialmadeof/orsurfacedwithanyofthefollowing
materials:
-Wood -CompressedPaper
-PlantFibers -Plastic
-Plywood/OSB -SheetRock(drywall)
Anymaterialthatcanigniteandburn:ameproofedornot,
plasteredornon-plastered.
NOTE:Thisinstallationmustconformwithlocalcodes.
Intheabsenceoflocalcodesyoumustcomplywiththe
UL1482-11,UL737-11,(UM)84-HUDandNPFA211in
theU.S.A.andtheULCS627-00andCAN/CSA-B365
InstallationCodesinCanada.APPROVED FOR MOBILE
HOME INSTALLATIONS IN the USA & CANADA.
NOTE:Hearth&HomeTechnologies,manufacturerofthis
appliance, reserves the right to alter its products, their
specicationsand/orpricewithoutnotice.
!
WARNING
This product and the fuels used to operate this product
(wood),andtheproductsofcombustionofsuchfuels,can
expose you to chemicals including carbon black, which
isknowntotheState ofCaliforniato causecancer,and
carbonmonoxide,whichisknowtotheStateofCalifornia
to cause birth defects or other reproductive harm. For
more information go to: www.P65Warnings.ca.gov
G. California Safety Information
H. Smoke, CO Detectors & Safety Tips
Smoke and CO Detectors
The use of smoke and carbon monoxide (CO) detectors
throughout the home is strongly advised, even if not
required by building codes or insurance regulations.
It is a good idea to install a smoke detector in the living
areas and each bedroom. Follow the smoke/CO detector
manufactures placement and installation instructions and
maintain regularly.
You may not, however, wish to install a detector in the
immediate vicinity of the stove. Depending on the sensitivity
oftheunit,thealarmcanbesetowhileyouaretending
thereoremptyingtheashes.Ifyouinstalladetectorinthe
same room, locate it as far away from the stove as possible.
Safety Tips
Convenientlylocatea“ClassA”reextinguishertocontend
with small res. Be sure the re extinguisher works and
is clearly visible.All occupants ofthehouseshould know
whereitis,andhowitoperates.Haveheavystovegloves
availablenearthestove.Have special safety accessories
(e.g.,ChildGuardScreen)availableforuseifsmallchildren
will be in the home.
Intheeventofastovepipeorchimneyre….
• Evacuatethehouseimmediately
• Notifytheredepartment
• If the re isn’t toothreatening, closing down the stove
tight,(damper,primaryair,alldoors)willhelptosmother
there.
• Inspect your stove, vent pipe and chimney for any
damage caused by the re and correct any damage
before using your stove again.
Fire Risk
• Donotleavethere unattendedwhenthe
door is unlatched
• Operateonlywithfrontdoorsandashpan
door closed.
• Unstablerewoodcouldfalloutoftherebox
creatingarehazardtoyourhome.
WARNING
!
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 58390-950i
A. Design & Installation Considerations
Consideration must be given to:
• Safety
• Convenience
• Tracow
Chimney and chimney connector required
Itisagoodideatoplanyourinstallationonpaper,usingexact
measurementsforclearancesandoorprotection,before
actuallybeginningtheinstallation.Ifyouare notusingan
existing chimney, place the appliance where there will be a
clearpassageforafactory-builtlistedchimneythroughthe
ceiling and roof.
Werecommendthataqualiedbuildinginspectorandyour
insurance company representative review your plans before
and after installation.
Ifthisapplianceisinanareawherechildrenmaybenear
it is recommended that you purchase a decorative barrier
to go in front of the appliance.
Remembertoalwayskeep
children away while it is operating and do not let anyone
operate this appliance unless they are familiar with these
operating instructions.
C. Negative Pressure
Negativepressureresultsfromtheimbalanceofairavailable
fortheappliancetooperateproperly.Itcanbestrongestin
lower levels of the house.
Causes include:
• Exhaustfans(kitchen,bath,etc.)
• Rangehoods
Combustion air requirements for furnaces, water
appliances and other combustion appliances
Clothes dryers
• Locationofreturn-airventstofurnaceorairconditioning
• ImbalancesoftheHVACairhandlingsystem
• Upperlevelairleakssuchas:
- Recessedlighting
- Attichatch
- Ductleaks
B. Fire Safety
To providereasonable re safety,the following should be
given serious consideration:
1. Install at least one smoke detector on each oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’s placement and installation instructions,
and be sure to maintain regularly.
2 2
Getting Started
Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
national codes and regulations.
• Consult insurance carrier, local building, reocials
or authorities having jurisdiction about restrictions,
installation inspection, and permits.
CAUTION
!
Asphyxiation Risk
DONOTCONNECTTHISAPPLIANCETO
ACHIMNEYFLUESERVICINGANOTHER
APPLIANCE.
WARNING
!
DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
2. AconvenientlylocatedClassAreextinguishertocontend
withsmallresresultingfromburningembers.
3. ACOdetectorshouldbeinstalledintheroomwiththe
appliance.
4. A practiced evacuation plan, consisting of at least two
escape routes.
5. Aplantodealwithachimneyreasfollows:
In the event of a chimney re:
a. Evacuatethehouseimmediately
b. Notifyredepartment.
Notice: Hearth & Home Technologies assumes no
responsibility for the improper performance of the
appliance system caused by:
Inadequatedraftduetoenvironmentalconditions
Down drafts
Tight sealing construction of the structure
Mechanical exhausting devices
• Overdraftingcausedbyexcessivechimneyheights
• Idealperformanceiswithachimneyheightof16Feet
(4.88m)measuredfromthebaseoftheappliance.
Asphyxiation Risk
Negativepressure can cause spillage
of combustion fumes, soot and carbon
monoxide.
Appliance needs to draft properly for safety.
WARNING
!
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/206 8390-950i
D. Tools And Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
E. Inspect Appliance and Components
• Removeapplianceandcomponentsfrompackagingand
inspect for damage.
• Reporttoyourdealeranypartsdamagedinshipment.
Read all the instructions before starting the installation.
Follow these instructions carefully during the
installation to ensure maximum safety and benet.
Tominimizetheeectsofnegativeairpressure:
• Installoutsideairwiththeintakefacingprevailingwinds
during the heating season
• Ensureadequateoutdoorairforall combustion appliances
and exhaust equipment
• Ensurefurnaceandairconditioningreturnventsarenot
located in the immediate vicinity of the appliance
• Avoidinstallingtheapplianceneardoors,walkways or
small isolated spaces
• Recessedlightingshouldbea“sealedcan”design
Attic hatches weather stripped or sealed
• Atticmountedductworkandairhandlerjointsandseams
taped or sealed
Basement installations should be avoided
•Reciprocatingsaw •Framingmaterial
• Pliers Hightempcaulkingmaterial
•Hammer •Gloves
• Phillips screwdriver • Framing square
•Flatbladescrewdriver •Electricdrillandbits
•Plumbline •Safetyglasses
•Level •Tapemeasure
• Misc. screws and nails
•1/2-3/4in.length,#6or#8self-drillingscrews
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Installation and/or use of any component part not
approvedbyHearth&HomeTechnologies.
Operating appliance withoutfully assembling all
components.
• Operatingwiththefrontdoorsopen.
• Operatingappliancewithoutlegsattached(ifsupplied
withappliance).
• DoNOTOverre-Ifapplianceorchimneyconnector
glows,youareoverring.
Any such action that may cause a re hazard.
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibility for, and the warranty will be
voided by, the following actions:
WARNING
!
Fire Risk
Inspectapplianceandcomponentsfor
damage. Damaged parts may impair safe
operation.
• DoNOTinstalldamagedcomponents.
• DoNOTinstallincompletecomponents.
• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
WARNING
!
When this room heater is not properly installed, a house
re may result. To reduce the risk of re, follow the
installation instructions. Contact local building or re
ocials about restrictions and installation inspection
requirements in your area.
WARNING
!
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 78390-950i
ATTENTION INSTALLER:
Follow this Standard Work Checklist
Thisstandardworkchecklististobeusedbytheinstallerinconjunctionwith,notinsteadof,theinstructionscontainedinthisinstallationmanual
Customer:
DateInstalled:
Lot/Address:
LocationofAppliance:
Installer:
Dealer/DistributorPhone#:
Serial#:
Model :
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions can lead to a re or explosion.
Appliance Install YES IF NO, WHY?
Veriedclearancetocombustibles.
Appliance is leveled and connector is secured to appliance.
Hearthextensionsize/heightdecided.
OutsideAirInstalled.
Floor protection requirements have been met.
Ifapplianceisconnectedtoamasonrychimney,itshouldbecleanedand
inspectedbyaprofessional.Ifinstalledtoafactorybuiltmetalchimney,
the chimney must be installed according to the manufacturers instructions
and clearances.
Chimney
Chimneycongurationcomplieswithdiagrams.
Chimneyinstalled,lockedandsecuredinplacewithproperclearance.
Chimneymeetsrecommendedheightrequirements(16Feet).
Roofashinginstalledandsealed.
Terminations installed and sealed.
Clearances
Combustiblematerialsnotinstalledonnon-combustibleareas.
Veriedallclearancesmeetinstallationmanualrequirements.
Mantels and wall projections comply with installation manual requirements.
Protective hearth strips and hearth extensions installed per manual
requirements.
Appliance Setup
Allpackagingandprotectivematerialsremoved.
Firebrick,baffleandceramicblanketinstalledcorrectly
All labels have been removed from the door.
Allpackagingmaterialsareremovedfrominside/undertheappliance.
Manual bag and all of its contents are removed from inside/under the
appliance and given to the party responsible for use and operation.
Hearth & Home Technologies recommends the following:
• Photographingtheinstallationandcopyingthischecklistforyourle.
• Thatthischecklistremainvisibleatalltimesontheapplianceuntiltheinstallationiscomplete.
Comments:Furtherdescriptionoftheissues,whoisresponsible(Installer/Builder/OtherTrades,etc.)andcorrectiveactionneeded:
Comments communicated to party responsible by on
(Builder/Gen.Contractor) (Installer) (Date)
F. Install Checklist
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/208 8390-950i
3 3
Dimensions and Clearances
A. Appliance Dimensions NOTE:FlueCollarsizeis6”(152mm)diameter(ID)
Figure 3.1-FrontView
15"
(381 mm)
25-1/16"
(637 mm)
16"
(406 mm)
23-1/2"
(597 mm)
24-1/4"
(616 mm)
6-1/4"
(159 mm)
7-1/2"
(191 mm)
Aspen C3 Specs
01/04/19 ts
24-1/2"
(623 mm)
27-3/16"
(691 mm)
5"
(127 mm)
Figure 3.3-TopView
15"
(381 mm)
25-1/16"
(637 mm)
16"
(406 mm)
23-1/2"
(597 mm)
24-1/4"
(616 mm)
6-1/4"
(159 mm)
7-1/2"
(191 mm)
Aspen C3 Specs
01/04/19 ts
24-1/2"
(623 mm)
27-3/16"
(691 mm)
5"
(127 mm)
Figure 3.2-SideView,OutsideAirInlet:3.5”Diameter(Usewith
3”FlexOutsideAirPipe)
15"
(381 mm)
25-1/16"
(637 mm)
16"
(406 mm)
23-1/2"
(597 mm)
24-1/4"
(616 mm)
6-1/4"
(159 mm)
7-1/2"
(191 mm)
Aspen C3 Specs
01/04/19 ts
24-1/2"
(623 mm)
27-3/16"
(691 mm)
5"
(127 mm)
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 98390-950i
B. Hearth Protection Requirements
Theoorareadirectlyunderandaroundthestovewillrequire
protectionfromstraysparksorembersthatmayescapethe
rebox.Type 1 hearthpad withno additional“R”valueis
required.
Use a noncombustible oor protector such as 1/4” non-
asbestos mineral board or equivalent, or 24 gauge
sheet metal.The oor protector may be covered with a
noncombustible decorative material if desired. Do not
obstruct the space under the heater.
ProtectionrequirementsvarysomewhatbetweentheUnited
StatesandCanadaasfollows:
U.S. Installations:Theoorprotectorisrequiredunderthe
stove and must extend at least 16” from the front of the stove
(B,Figure3.4),andatleast6”fromthesides(A,Figure3.4)
and0”tothe rear.Itmustalsoextendunderthechimney
connectorand2”toeitherside.(C,Figure3.4)
In Canada:A noncombustible oor protector is required
undertheheater.Theoorprotectormustextend18”(457
mm)tothefront(B,Figure3.4)and9”(229mm)fromthe
sidesandrear.(A,Figure3.4)
Figure 3.5 - Supporting timbers underfireplace hearths are
considered to be combustible.
Comb Floor Dia
01/07/19 ts
Wood framing requires
protection from radiant heat
Fireplace Hearth Protection:
For all replace installations, follow the oor protection
guidelines described above.
Keep in mind that many raised hearths will extend less than
the required clearance from the front of the heater when
it is installed. In such cases, sucient oor protection as
described above must be added in front of the hearth to
satisfy the minimum oor protector requirement from the
frontofthestove:16”(406mm)fromthefrontintheUnited
Statesand18”(457mm)fromthefrontinCanada.
Hearthrugsdonotsatisfytherequirementsforoorprotection
astheyareonlyre-retardant,notreproof.
Fireplace installations also have special clearance
requirements to the side walls, side decorative trim and
replacemantel.Refertotheinformationonreplaceand
mantel trim shields in this section.
Floor Protection Requirements
U.S. Canada
A 8" 9"(229mm)
B 16" 18"(457mm)
C 8” 8"(203mm)
D 39-7/16” 48"(1219mm)
E 25-1/2" 31"(787mm)
Floor Protection
05/21/19 ts
A
A
A
B
D
E
C
D
B
E
A
A
Figure 3.4 -These dimensionsare minimumrequirements only.
Usegreaterdimensionswheneverpossible.
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/2010 8390-950i
C. Clearances To Combustibles
Note: It is recommended that you have the unit in place for proper measurements and installation.
Vertical Venting Conguration
Description Single-Wall Pipe
A SideWalltoAppliance 14"/356 mm
B BackWalltoAppliance 8"/203 mm
C SideWalltoConnectorPipe 18-1/2"/470 mm
D BackWalltoConnectorPipe 11"/279mm
Description Double-Wall Pipe
A SideWalltoAppliance 14"/356 mm
B BackWalltoAppliance 3"/76 mm
C SideWalltoVentPipe 18"/457 mm
D BackWalltoVentPipe 5-1/2"/140mm
Vertical Vent, Horizontal Exit
Description Single-Wall Pipe
A SideWalltoAppliance 14"/356 mm
B BackWalltoAppliance 8"/203 mm
C SideWalltoVentPipe 18-1/2"/470 mm
D BackWalltoVentPipe 11"/279mm
E MinimumVertical 0"/0mm
F Minimum Floor to Ceiling 84"/2134mm
G MinimumVentPipetoCeiling 20”/508mm
C
A
D
B
Figure 3.6
D
B
E
C
A
F
G
Figure 3.7
G
H
H
G
Figure 3.8
Vertical Vent, Corner Conguration
Location Single-Wall Pipe
G Corner to Wall 6"/152mm
H VentPipetoWall 12-3/4"/324mm
Location Double-Wall Pipe
G Corner to Wall 3"/76mm
H VentPipetoWall 9"/229mm
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 118390-950i
Alcove Clearances
Description Single-Wall Pipe
A SideWalltoAppliance 14"/356 mm
B BackWalltoAppliance 8"/203 mm
C SideWalltoVentPipe 18-1/2"/470 mm
D BackWalltoVentPipe 11"/279mm
E Minimum Floor to Ceiling 63"/1600mm
F MinimumVentPipetoCeiling 20”/508mm
Note: Clearances may be reduced using NFPA 211
clearance reduction methods, if permitted by local code
enforcementocials.
D
B
F
C
A
E
F
Figure 3.9
When:
A=9"(229mm)Max.
B=22-1/2(572mm)Min.
A=7-1/2"(191mm)Max.
B =21"(533mm)Min.
A=6"(152mm)Max.
B=19-1/2"(495mm)Min.
A=4-1/2"(114mm)Max.
B=18"(457mm)Min.
A=3"(76mm)Max.
B=16-1/2"(419mm)Min.
A=1-1/2"(38mm)Max.
B=15"(381mm)Min.
Min. 15"
(381mm)
1
11
22"
(38mm)
Max. 9"
(229mm)
22
11
22"
(572mm)
A
B
Figure 3.10-Mantelandtrimclearances.
Fireplace Clearances:
Areplaceinstallationrequiresspecialclearancebetween
the side of the stove and the right and left walls, the side of
thestoveandthedecorativesidetrimonthereplaceface,
and the top of the stove and the mantel.
MaximumMantel depth (A, Figure 3.10) of a combustible
mantelis9”(230mm).Atthatdepth,theclearancetothe
stovetop(B)mustbeaminimumof22-1/2"(572mm).
TopTrim(C)protrudinglessthan1-1/2"(38mm)fromthe
faceofthereplacemustbeaminimumof12"(305mm)
from the stove top. This clearance may not be reduced by
shielding.
For every 1-1/2"(38mm)incrementthatthetrimormantel
extends in depth, the clearance from the stove top must also
be increased by 1-1/2"(38mm).
SideTrimmusthaveaminimumclearanceof8"(203mm),
measuredfromthestove'stopedge.(D,Figure3.11)
B Mantel 22-1/2"(572mm)
C *Top Trim 12"(305mm)
D SideTrim 8"(203mm)
*Materialislessthan1-1/2"(38mm)Thick
Figure 3.11-Mantelandtrimclearances.
ST253a
aspen
trim clearances
12/15/99 djt
C
DD
B
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 128390-950i
E. Chimney Termination Requirements
Follow manufacturers instructions for clearance, securing
ashingandterminatingthechimney.Figures3.13&3.14.
• MusthaveanapprovedandListedcap
Must not be located where it will become plugged by
snow or other material
• Must terminate at least 3 feet (91 cm) above the roof
andatleast2feet(61cm)aboveanyportionoftheroof
within10feet(305cm).
Must be located away from trees or other structures
NOTICE:
Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions aect
performance.
• Chimney height may need adjustment if smoking or
overdraft occurs.
D. Locating Your Appliance & Chimney
Location of the appliance and chimney will aect
performance. As shown in Figure 3.12 the chimney should:
• Installthroughthewarmspaceenclosedbythebuilding
envelope. This helps to produce more draft, especially
duringlightinganddiedownofthere.
Penetrate the highest part of the roof. This minimizes the
aectsofwindturbulenceanddowndrafts.
NOTICE: Locating the appliance in a basement or in a
location of considerable air movement can cause intermittent
smokespillagefromappliance.Donotlocateappliancenear
Frequently open doors
Central heat outlets or returns
• Consider the appliance location in order to avoid oor
and ceiling attic joists and rafters.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Yourlocaldealeristheexpertinyourgeographicareaand
canusuallymakesuggestionsordiscoversolutionsthatwill
easilycorrectyourueproblem.
Figure 3.12
Recommended
Location
Marginal
Location
Location
Not
Recommended
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
Windward
Leeward
Outside Air Termination Cap
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/2013 8390-950i
F. Chimney Location (2-10-3 Rule)
These are safety requirements and are not meant to assure proper ue draft.
Thisapplianceismadewitha6”(152mm)diameterchimneyconnectorastheuecollarontheappliance.
• Changingthediameterofthechimneycanaectdraftandcausepoorperformance.
• Itisnotrecommendedtouseosetsandelbowsataltitudesabove4000feetabovesealevelandorwhenthereareother
factorsthataectuedraft.
3 ft (91 cm)
Minimum
Less than 10 ft (305 cm)
2 ft (61 cm)
3 ft (91 cm)
Minimum
10 ft (305 cm) To Nearest Roofline
2 ft (61 cm)
Pitched Roof
Figure 3.13
10 ft. (305 cm) or more
3 ft. (91 cm) Minimum
Less than 10 ft. (305 cm)
2 ft. (61 cm) Minimum
3 ft. (91 cm) Minimum
Wall or Parapet
Flat Roof
Figure 3.14
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 148390-950i
4 4
Chimneys & Venting
A. Venting & Draft Management
A stove is part of a system, which includes the chimney,
the operator, the fuel, and the home. The other parts of the
systemwillaecthowwellthestoveworks.Whenthereis
agoodmatchbetweenalltheparts,thesystemworkswell.
Wood stove or insert operation depends on natural
(unforced)draft.Naturaldraftoccurs when the exhaustis
hotter(andthereforelighter)thantheoutdoorairatthetop
ofthechimney.Thebiggerthetemperaturedierence,the
stronger the draft. As the hot gases rise through the chimney
they provide suction or ‘draw’ that pulls air into the stove for
combustion.Aslow,lazyrewiththestove’sairinletsfully
openindicatesaweakdraft.Abriskre,supportedonlybyair
entering the stove through the normal inlets, indicates a good
draft. The stove’s air inlets are passive; they regulate how
much air can enter the stove, but they don’t move air into it.
Depending on the features of your installation - steel or
masonry chimney, inside or outside the house, matched to
thestove’soutletoroversized-yoursystemmaywarmup
quickly,oritmaytakeawhiletowarmupandoperatewell.
With an ‘airtight’ stove, one which restricts the amount of air
gettingintotherebox,thechimneymustkeepthestove’s
exhaust warm all the way to the outdoors in order for the
stovetoworkwell.Somechimneysdothisbetterthanothers.
Here’salistoffeaturesandtheireects.
Note:ElbowandTee’sreducethedraftofachimneysystem.
Designtheinstallationtominimizechangesindirection.No
more than 2 tee’s or elbows may be used.
Masonry Chimney
Masonry is a traditional material for chimneys, but it can
perform poorly when it serves an ‘airtight’ stove. Masonry
isaveryeective‘heatsink’-itabsorbsalotofheat.Itcan
cool the chimney gases enough to diminish draft. The bigger
thechimney,thelongerittakestowarmup.It’softenvery
diculttowarmupanoutdoormasonrychimney,especially
anoversizedone,andkeepitwarmenoughtomaintainan
adequate draft.
Steel Chimney
Mostfactory-madesteelchimneyshavealayerofinsulation
around the inner ue. This insulation keeps the chimney
warm. The insulation is less dense than masonry, so a steel
chimneywarmsupmorequicklythanamasonrychimney.
Steeldoesn’thavethegoodlooksofmasonry,butitperforms
much better.
Indoor/Outdoor Location
Becausethechimneymustkeepthesmokewarm,it’sbestto
locate it inside the house. This uses the house as insulation
fortheueandallowssomeheatreleaseintothehome.An
indoorchimneywon’tloseitsheattotheoutdoors,soittakes
lessheatfromthestovetoheatitupandkeepitwarm.
Single Venting
Each‘airtight’stoverequiresitsownue.Ifanairtightstove
is vented to a ue that also serves an open replace, or
aleakierstove,it’seasierforthe chimney drafttopullair
in through those channels and performance of the stove
suers.Imagineavacuumcleanerwithaholeinthehoseto
understandtheeecthere.Insomecasestheotherappliance
can even cause a negative draft through the stove, and result
in a dangerous draft reversal.
Draft
TheVermontCastingsAspenC3requiresaminimumdraftof
10 Pa or .04” of W.C. Draft too low can cause low heat output
and a sluggish burn. Draft higher than 30 Pa or .12 of W.C.
canresultinshortburntimesandoverring.Ensurethedraft
of the chimney is in correct range for operating the Aspen C3.
Flue Sizing
The inside size of a chimney for an ‘airtight’ stove should
matchthesizeofthestove’sueoutlet.Whenachimney
serves an airtight stove, more is not better; in fact, it can be a
disadvantage.Hotgasesloseheatfasterastheytravelslower
throughachimney;ifweventastovewithasix-inchuecollar
(28squareincharea)intoa10x10"ue,thegasesslowto
one third their original speed. This allows the gases to cool
morerapids,whichweakensdraftstrength.Ifanoversizedue
is also outside the house, the heat it absorbs gets transferred
totheoutdoorairandtheueusuallystayscool.
Itiscommonforamasonryue,especiallyoneservinga
replace,tobeoversizedforthestove.Itcantakequiteawhile
towarmupsuchaue,andtheresultscanbedisappointing.
Thebestsolutiontoanoversizedueisaninsulatedsteel
chimneyliner,thesamediameterasthestoveorinsertsue
outlet;thelinerkeepstheexhaustwarm,andtheresultisa
strongerdraft.Annon-insulatedlinerisasecondchoice-the
linerkeepstheexhaustrestrictedtoitsoriginalsize,butthe
hot gases still must warm up the air around the liner. This
makesthewarm-upprocesstakelonger.
Pipe & Chimney Layout
Everyturntheexhaustmusttakeasittravelstothechimney
top will slow it down. The ideal pipe and chimney layout is to
vent vertically into a completely straight and vertical chimney.
Ifyouarestartingfromscratch,usethislayoutifpossible.
Ifthestovepipemustelbowtoenterachimney,locatethe
thimble about midway between the stove top and the ceiling.
This achieves several goals: it allows the gases to speed up
before they must turn, it leaves some pipe in the room for
heattransfer,anditgivesyoulong-termexibilityforinstalling
adierentstovewithoutrelocatingthethimble.
Thereshouldbenomorethaneightfeetofsingle-wallstove
pipe between the stove and a chimney; longer runs can cool
the exhaust enough to cause draft and creosote problems.
With prefabricated chimney, bring it down to six to eight feet
from the stove. With a masonry chimney, arrange the pipe
so that it turns into the chimney within eight feet of the stove.
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 158390-950i
B. Venting Components
Chimney Connector: It is also known as flue pipe or
appliance pipe. The chimney connector joins the appliance
tothechimney.Itmustbea6”(152mm)minimumdiameter
24 gauge mild steel black or 26 gauge blued steel, or an
approvedair-insulateddoublewallventingpipe.
Thimble:Amanufacturedorsite-constructeddeviceinstalled
in combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet NFPA
211Standards.Prefabricatedmustbesuitableforusewith
selectedchimneyandmeetUL103TypeHTStandards.Follow
instructions provided by the manufacturer for manufactured
thimbles for masonry chimney and prefabricated chimneys.
Chimney: The chimney can be new or existing, masonry
or prefabricated and must meet the following minimum
requirementsspeciedinsection4C“ChimneySystems”.
C. Chimney Systems
Prefabricated Metal Chimney
Must beminimum 6” (152 mm) diameter (ID) high
temperaturechimneylistedtoUL103HT(2100°F)or
ULCS629M.
Must use components required by the manufacturer for
installation.
Must maintain clearances required by the manufacturer
for installation.
• Refertomanufacturersinstructionsforinstallation.
Chimney
Connector
Insulated " T "
Flashing
Listed Termination Cap
Listed Chimney
Storm Collar
Wall Support
Roof Brace (if required)
Thimble
Trim Collar on Inside Wall
Floor
Protection
Figure 4.1 - Prefabricated Exterior Chimney
NOTE: InCanadawhenusingafactory-builtchimneyit
must be safety listed, Type UL103 HT (2100 °F) CLASS
“A” or conforming to CAN/ULC-S629M, STANDARD
FOR 650 °C FACTORY-BUILT CHIMNEYS.
Floor
Protector
Chimney
Connector
Ceiling Support
Listed Chimney
Storm Collar
Flashing
Listed
Termination Cap
Figure 4.2 - Prefabricated Interior Chimney
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/2016 8390-950i
Thimble
Siteconstructedformasonrychimneyinstallation:
Components
A minimum length of 12” (305 mm) (longer for thicker
walls) of solid insulated factory-built chimney length
constructed to UL 103 Type HT 6” (152 mm) inside
diameter.Chimneyneedstoextendaminimumof2”(51
mm)fromtheinteriorwallandaminimumof1”(25mm)
from the exterior wall.
Wall spacer, trim collar and wall band to t solid pack
chimney selected.
Minimum8”(203mm)diameterclaylinersection(ifnot
alreadypresentinchimney)andrefractorymortar.
When jurisdiction requires install approved chimney liner
in masonry chimney.
Air Clearances
• Masonry chimney clearance must meet NFPA 211
minimum requirement of 2” (51 mm) to sheet metal
supports and combustibles.
• Minimumof1”(25mm)clearancearoundthechimney
connector.
• Topofwallopeningisaminimumof13-1/2”(343mm)
fromceilingor4-1/2”(114mm)belowminimumclearance
speciedbychimneyconnectormanufacturer.NFPA211
minimumverticalclearanceof18”(457mm)fromchimney
connector and ceiling or minimum recommended by
chimney connector manufacturer. Figure 4.3
Instructions
1. Open inside wall at proper height for the chimney
connector to enter the masonry chimney. Figure 4.3
2. Entryholetomasonrychimneymustbelinedwithan8”
(203mm)minimumdiameterclayliner,orequivalent,
secured with refractory mortar.
3. Construct a 17” x 17” (432 mm x 432 mm) outside
dimension frame from 2 x 2framinglumbertot into
wallopening.Insideopeningofframeshouldbenoless
than14”x14”(356mmx356mm).Figure4.4.
Attach the wall spacer to the chimney side of the frame.
5. Nailtheframeintothewallopening.Thespacershould
be on the chimney side.
6. Insertthesectionofthesolidinsulatedchimneyintothe
outer wall of the masonry chimney.
7. Tightly secure the length of the solid insulated chimney
with the wall band to the masonry chimney.
8. Insertasectionofchimneyconnectorintothechimney.
Makesureitdoesnotprotrudepasttheedgeoftheclay
chimney liner inside the chimney.
9. Sealtheendofthechimneyconnectortotheclayliner
with refractory mortar.
10.
Installtrimcollararoundthesoldpackchimneysection
.
Solid Pack Chimney with Metal Supports as a Thimble
Trim Collar
Chimney Section
with 2 inch (51 mm)
Clearance to
Combustibles
Chimney
Connector
Fire Clay Flue Liner
with Airspace
Masonry
Chimney
Wall Band to
Secure Chimney
Section
Wood Studs Used for
Framing - Spaced 2
inch (51 mm) clearance
from Masonry Chimney
Wall Spacer
Figure 4.3
Fire Risk
DoNOTpackinsulationorothercombustibles
between spacers.
WARNING
!
• ALWAYSmaintainspeciedclearancesaroundventing
and spacers.
• Installspacersasspecied.
Failuretokeepinsulationorothermaterialawayfromvent
pipemaycausere.
Solid Pack Chimney with Metal Supports as a Thimble
(Cont’d)
1 inch (35 mm) Air Space
to Chimney Section
Min. Clearance
2 inch (51 mm)
Min. Chimney Clearance to Wall Spacer
and Combustible - 2 inch (51 mm)
Chimney
Flue Liner
Fireclay Liner
or Equivalent
Masonry Chimney
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney Section
Chimney
Connector
Figure 4.4
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 178390-950i
Chimney Height / Rise and Run
Thisproductwasdesignedforandtestedona6”(152mm)
chimney,16feet(4.88m)high,(includesapplianceheight)
measured from the base of the appliance. The further your
stackheightordiametervariesfromthisconguration,the
possibility of performance problems exists.
Chimney height may need to be increased by 2
-3%per
each1000feetabovesealevel.Itisnotrecommendedto
useosetsorelbowsataltitudesabove4000feetabovesea
levelorwhenthereareotherfactorsthataectuedraft.
Factory-built(Double-Wall)listedchimneyconnector
A listed connector (vented) must be used when installing
this appliance in a mobile home. The listed connectors must
conformtoeachothertoensureapropertandseal.
Fire Risk
InspectionofChimney:
• Chimney must be in good condition.
•MeetsminimumstandardofNFPA211
•Factory-builtchimneymustbe6”(152mm)UL103HT.
WARNING
!
WARNING
!
Asphyxiation Risk
DO NOT CONNECT THIS Appliance TO A
CHIMNEY FLUE SERVICING ANOTHER
APPLIANCE.
DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow ue gases to enter the house.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this appliance. For assistance or additional information
consultaqualiedinstaller,serviceagencyoryourdealer.
WARNING
!
Flue Gas
Direction
Crimped
End
Toward
Appliance
Secure pipe sections with a
minimum of 3 screws
Figure 4.7 - Chimney Connector (Appliance Pipe)
Fire Risk
Follow Chimney Connector Manufacturers
InstructionsforProperInstallation.
ONLYuseconnector:
WARNING
!
Within the room, between appliance and ceiling or wall.
ConnectorshallNOTpassthrough:
Attic or roof space
Closet or similar concealed space
Floor or ceiling
Maintain minimum clearances to combustibles
Figure 4.6-Acceptablemethodforpassing singlewallchimney
connector through combustible walls.
Note:HHTrecommendstheuseofULlistedsinglewallthimbles.
masonry wall pass through
w/ single wall connector
01/09/19
Min.2”(51mm)Chimneyclearance
tobrickandcombustibles
A = Minimum 12” (305 mm) brick
construction between liner and
combustible framing materials
Min. 12”
(305mm)
Fire clay
liner
A
A
Chimney Flue
Fire clay liner
Masonry
Chimney
constructed
toNFPA211
Chimney
connector
D. Installing Chimney Components
Chimney Connector
Singlewallconnectororappliancepipe
This must be at least 24 gauge mild steel or 26 gauge blue
steel. The sections must be attached to the appliance and
toeachotherwiththecrimped(male)endpointingtoward
theappliance.Alljoints,includingtheconnectionattheue
collar,shouldbesecuredwith3sheetmetalscrews.Make
sure to follow the minimum clearances to combustibles.
Where passage through the wall, or partition of combustible
construction is desired in Canada, the installation shall
conformtoCAN/CSA-B365.
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/2018 8390-950i
A. Removing Unit from Skid
1.Inspect the stove and contents for shipping damage
ormissingparts.Immediatelynotifyyourdealerofany
damage. Do not install this stove if any damage is evident
or any parts are missing.
2.Remove(4)5/16X2”lagscrewsfromshippingbrackets.
B. Install Stove Legs
Leg installation will beaccomplishedmost easily with the
help of an assistant who can tilt the stove onto its side while
you attach the legs.
1. With your assistant holding the stove up on its side,
remove(2)shippingbracketsbyremovingthe3/8”Hex
bolts and washers. Note: DO NOT discard these bolts
andwashersastheywillbere-usedtoinstallthelegs.
2. Placelegsateachcorneroftheunitandinstallthe3/8”hex
head bolts and washer previously removed. The shoulder
of the legs should seat within the locator bosses cast into
the stove bottom at each corner, Figure 5.1. Tighten the
bolts with the wrench. CAUTION: Overtighening can
strip tapped threads.
3. With your assistant, lift the stove up onto its legs and hold
it in a tilted position to install the remaining two legs with
hex bolts and washers.
5 5
Appliance Set-Up
Carefully tilt the stove on the
shippingbracketstoinstallone
front and one rear leg.
Then tilt the stove up on those
legs to install the remaining two.
Figure 5.1-Installlegsononesideofstovethentheother.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Installation and/or use of any component part not
approvedbyHearth&HomeTechnologies.
Operating appliance withoutfully assembling all
components.
• Operatingwiththefrontdoorsopen.
• Operatingappliancewithoutlegsattached(ifsupplied
withappliance).
• DoNOTOverre-Ifapplianceorchimneyconnector
glows,youareoverring.
Any such action that may cause a re hazard.
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibility for, and the warranty will be
voided by, the following actions:
WARNING
!
Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
national codes and regulations.
• Consult insurance carrier, local building, reocials
or authorities having jurisdiction about restrictions,
installation inspection, and permits.
CAUTION
!
Adjust the Leg Levelers
Liftthestoveslightlysothereisnoweightonthelegwhile
makingtheadjustment.
C. Install Fire Brick
InstalltheFirebrickinthefollowingorder:BottomBricks
rst,RearBrickssecondandSideBricksthird,Figure5.2.
Bottom Brick
Side Brick
Side Brick
Rear Brick
Figure 5.2-InstallFirebrick
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/2019 8390-950i
D. Outside Air Installation
Asourceofair(oxygen)isnecessaryinorderforcombustion
totakeplace.Whatevercombustionairisconsumedbythe
remustbereplaced.Airisreplacedviaairleakagearound
windowsandunderdoors.Inhomesthathavetightlysealed
doors and windows, an outside air source is needed. An
OutsideAir box is
installed from factory to accommodate
outside air.
Items Needed for Installation (not supplied)
Phillips head screw driver
Wire ties
Plastic outside air vent
• 3”FlexorRigidDuct
• 3”OutsideAirTerminationCapwithScreen
• Siliconesealant
Drills and saws necessary for cutting holes through
thewallorooringinyourhome.
1. Removeallmaterialsfrompackingbox.
2. Usinga#2Phillipsscrewdriverattachtheexadapterto
theapplianceusing4screws.Figure5.3&5.4.
3. Floor&RearInstallation:Cuta3”(76mm)holeinoutside
walloroortoaccommodateoutsideairpiping.Use3”
(76mm)aluminummetalexorrigidpipingtodirectly
connectoutsideairtoapplianceintake.Usethesupplied
terminationcapwitharodentscreen.Sealbetweenthe
wall(oroor)andthepipewithsiliconetopreventmoisture
penetration.
Figure 5.3-RearInstallation
Figure 5.4-FloorInstallation
Fire Risk
Asphyxiation Risk
Do not draw outside combustion air from:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
Close proximity to exhaust vents or chimneys
Fumes or odor may result
WARNING
!
Asphyxiation Risk
Outside air inlet must be located to prevent
blockagefrom:
WARNING
!
• Leaves • Snoworice • Otherdebris
Blockagemaycausecombustionairstarvation
Smoke spillage may set o alarms or irritate sensitive
individuals.
Asphyxiation Risk
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaustue.
WARNING
!
Fire will not burn properly
Smoke spillage occurs whendoorisopeneddueto
air starvation
Vermont Castings • Aspen C3 Installation Manual_R5 • 2019 - ___ • 01/20 208390-950i
6 6
Mobile Home Installation - Approved for USA & Canada Installations
A. Mobile Home Installation
Mobile home approval - USA & Canada.
TheAspenC3isapprovedforuseinmanufactured(mobile)
homeswheninstalledwiththeMobileHomeBracketsand
any approved local codes.
Inadditiontothestandardinstallationrequirementsdescribed
in this manual, the following guidelines apply to mobile home
installations:
1. Thestovemustbepermanentlysecuredtotheoorusing
themobilehomebracketssupplied(locatedattherearof
theunitundertheoutsideairbox)alongwithscrewsor
lagbolts(notsupplied).Note:Themobilehomebrackets
will need to removed from the outside air box. Note: The
mobilehomebracketsgetinstalledbetweenthelegleveler
and cast leg, Figure 6.1
INSTALLATION MUST COMPLY WITH MANUFACTURED
HOME AND SAFETY STANDARD (HUD), CFR 3280,
PART 24.
WARNING
!
NEVER INSTALL IN A ROOM INTENDED FOR
SLEEPING.
WARNING
!
MAINTAIN STRUCTURAL INTEGRITY OF MOBILE
HOME:
FLOOR, WALL, CEILING AND/OR ROOF. DO NOT
CUT THROUGH:
FLOOR JOIST, WALL STUDS, OR CEILING
TRUSSES.
ANY SUPPORTING MATERIAL THAT WOULD
AFFECT THE STRUCTURAL INTEGRITY.
CAUTION
!
NEVER DRAW OUTSIDE COMBUSTION AIR FROM:
WALL, FLOOR OR CEILING CAVITY.
ENCLOSED SPACE SUCH AS AN ATTIC OR
GARAGE
CAUTION
!
2. The stove must have a permanent connection to the
outside to supply combustion air.
3. A listed chimney system, including roof thimble,spark
arrestor,chimneysupports,roofashingandanyother
components suitable for use in mobile homes must be
used. The chimney system must comply with the standard
forChimneysFactory-BuiltResidentialTypeandBuilding
HeatingAppliancesUL103.
4. The chimney must be attached directly to the stove and
mustextendatleast3’(914mm)abovethepartofthe
roof through which it passes. The top of the chimney must
extendatleast2’(610mm)abovethehighestpointofany
partofthemobilehomestructurewithin10’(3m)ofthe
chimney.
5. Ifthechimneyexitsthemobilehomethroughawallata
point 7 feet or less above the ground level on which the
mobile home is located, a guard or other noncombustible
enclosuremustbettedatthepointofexitandextendup
toaheightof7’(2.1m).Anyopeningsinthisguardmust
besmallerthan3/4”(19mm).
6. Checkalllocalbuildingcodes,specicallythoserelatedto
mobilehomes.Otherrequirementsmaybeapplicableto
chimney system removal for transportation of the mobile
home.
7. Seal all penetrations between the venting system and
mobilehomestructurewithsilicone(orotheracceptable
sealant)tocompletelysealthedwellingfromoutsideair
inltration.
Figure 6.1
MobileHomeBrackets
MobileHomeBracketsLocation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Vermont Castings Aspen C3 Wood Burning Stove Owner's manual

Category
Stoves
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI