第 1 页 共 3 页
HK-10_01 User’s Guider
1 Technical data sheet
1.1 Temperature measurement range and accuracy:-50℃~99℃, ±1℃(-40℃~50℃), ±2℃(others)
-58℉~210℉, ±2℉(-40℉~122℉), ±4℉(others)
1.2 Resolution: 0.1℃ or 1℉
1.3 Power supply:12VDC
1.4 Relay outputs: Refrigeration equipment: 5A/12VDC
Heater: 10A/240VAC
1.5 Operating temperature: 0℃~55℃
1.6 Storage temperature: -25℃~75℃
1.7 Relative humidity: 20%~85% (no condensing)
2 Panel and Operation
3 Indicator light description
3.1The cool indicator lights up when the refrigeration equipment is working, flashes during the
startup delay time.
3.2 The heat indicator lights up when the heater is working, flashes during the startup delay time.
4 Key function
4.1 Edit the value of set point
Press and hold the up key for 3 seconds to display the value of set temperature and flash,then press
the up key or down key to adjust the set temperature, there is no key operation for more than 5
seconds, the controller will automatically save the changed temperature and exit the temperature
change operation.
4.2 Turn on or off
In the on state, press the down key for 3 seconds to turn off the controller.
In the off state, press the down key for 3 seconds to turn on the controller.
4.3 Cancel alarm sound
When the buzzer gives an alarm, press any key to cancel the alarm sound.
4.4 Edit the value of other parameters
Press the up key and down key at the same time for 3 seconds to display “F0”and flash,then press
the up key and down key at the same time to switch the parameter and the menu item,press the up
key or down key to adjust the value of the parameters or select the menu “F0~F12”, there is no key
operation for more than 30 seconds or press the up key and down key at the same time for 3 seconds
the controller will save the changed value and exit the parameters change operation.