SimpliFire Wescott Mantel Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the SimpliFire Wescott Mantel Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/23
Wescott Mantel Kit
MK-WS-INC36
- Instructions -
NOTICE: Before starting, the walls and oor in the area of the installation should be clean, plumb and level. Any
major deviation should be remedied before installing the appliance, marble or mantel.
For Model(s):
SF-INC36
NOTE: To be installed on nished oors only.
CAUTION
Sharp Edges
Wear protective gloves and safety
glasses during installation.
• These instructions apply only to the mantel and facing
material that will surround the rebox.
• See the replace manufacturer’s installation instructions to
ensure that all clearance and installation requirements are
being met.
PREPARATION
Before beginning installation of this mantel, verify that the walls
and oor in the area of the installation are clean, plumb and
level. Any major deviation should be remedied before installing
the appliance, marble or the mantel /cabinet.
These questions should also be considered and answered
before beginning installation of the mantel.
a. Is base molding already installed?
b. Where are the electrical outlets or rebox switch?
c. Is there enough distance between windows and edge
of cabinet?
d. Is the replace centered between walls?
e. Will installation interfere with return air vent locations?
f. Is the replace centered between windows?
g. Where are the electrical & cable outlets positioned?
It is recommended that two people assemble this mantel due to
its weight and upright positioning.
CAUTION
WARNING
Risk of Fire
Improper installation or adjustment can
cause injury or property damage. For
assistance or additional information, contact
a qualied installer, service agency or the
electrician.
Comply with all minimum clearances to
combustibles as specied in the appliance
manual.
CAUTION
Leave this manual with party responsible for
use and operation.
Tools and Supplies Needed
Phillips Screwdriver (No. 3 preferred)
Tape Measure, Pencil
Portable Drill
1/16" and 3/32" Drill Bits
T10 Driver/Bit
Hammer
Stud Finder
Nail Set
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/232
L (pre-installed)
M (pre-installed)
N (pre-installed)
O
P
ITEM DESCRIPTION QUANTITY
LM6 - CAM PIN (pre-installed) 6
M CAM LOCK FASTENER (pre-
installed) 12
N WOODEN DOWELS (pre-
installed) 6
O 3" SCREWS 12
PFINISHING NAILS 12
QWALL BRACKET 1
R POWER CORD 1
SSTRAIN RELIEF 1
Fasteners
A
B
C
D
E
G
H
F
ITEM DESCRIPTION QUANTITY
A Top Assembly 1
BLeft Leg Assembly 1
CRight Leg Assembly 1
D Top Trim Board 1
E Left and Right Trim Board 2
FLedger Board 1
G Top Scribe Molding 1
HLeft and Right Scribe Molding 2
Kit Components
Q
RS
T-10
3
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/23
How to use Cam Pin and Cam Lock Fastener:
ARROW
CAM LOCK
FASTENER
PRE-DRILLED
HOLE
PUSH THE CAM LOCK
FASTENER INTO PART.
THE ARROW OF THE CAM
LOCK FASTENER MUST
POINT TO PRE-DRILLED
HOLE ON THE EDGE OF
THE BOARD.
INSERT THE CAM PIN INTO THE
CAM LOCK FASTENER.
USING A PHILLIPS SCREWDRIVER,
ROTATE THE CAM LOCK FASTENER
CLOCKWISE TO LOCK THE CAM PIN.
Step 1
Step 2
Step 3
Note: Do not overtighten. Overtightening may result
in broken fasteners or damage the nished edge of the
mantel.
Starting Position Locked Position Do not turn past 1/2 turn
Step 4
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/234
Product Dimensions
A
B
C
I
F
D
E
H
G
J
Model A B C D E F G H I J
MK-WS-INC36 in. 61-7/8 49-5/8 54 14-7/16 11-1/4 5-1/2 12-5/8 5 36 33-7/8
mm 1571 1261 1372 367 286 140 321 127 914 860
Electrical Outlet Locations
5-1/2 (140 mm)
12
36
(914 mm)
Note: Make sure
electrical receptacle is
located in one of the
shaded areas.
36
(914 mm)
27
(686 mm)
27
(686 mm)
33-3/4
(857 mm)
27-1/8
(689 mm)
6-1/2
(165 mm)
6
(152 mm)
(305 mm)
5
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/23
CUTTING PACKAGING MATERIAL
COULD DAMAGE THE PRODUCT.
Mantel Preparation
Remove the Mantel Kit parts and hardware from the
packaging.
Renishing
The mantel comes primed, ready to accept paint. The
following steps are recommended for applying paint
prior to assembling the mantel.
Properly cover any areas of work space that paint is
not desired.
Lightly scu the existing nish with 320 grit sandpa-
per.
Remove dust using lint free cloth.
Apply paint to evenly cover the mantel. Wait the
recommended amount of time for drying per the
paint instructions.
Apply additional top coats until desired coverage is
achieved.
NOTICE:
Follow all recommended guidelines for the materials
that are being used.
Do not paint near the appliance.
Do not paint while the appliance is operating.
Always wear appropriate gloves, eye protection,
clothing and a respirator or mask when painting.
WARNING:
Determine Power Location
Option 1: Hidden Power location
Locate outlet in access hole of appliance. See page
4.
Option 2: Exposed Power Cord
Make sure outlet is within six feet of center of appli-
ance.
Drill 1/2" hole within bottom two inches of the side
mantel leg. See Figure 1.
2 in (51 mm)
2 in (51 mm)
Ø 1/2 in
(13 mm)
Figure 1
Baseboard Removal
Remove baseboard from wall where the appliance
and mantel will be installed.
Baseboard must be removed where the mantel will
be installed. See dimensions on page 4 for refer-
ence.
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/236
48-7/8 in
(1242 mm)
(O) x 2
(min.)
Assembly
1. Position the top assembly (A) of mantel upside down
on a at, clean, non-abrasive surface.
2. Dowels and cam pins are shipped pre-inserted in the
end of the leg asembly (B). See Figure 2. Before
installing mantel leg, use a Phillips screwdriver to
ensure the cam pins are secured in the leg with the
cam fasteners positioned at 1/2 turn as shown in
Step 4, page 3.
3. Attach left leg assembly (B) to the top assembly (A)
by inserting dowel and cam pin into matching holes
on ends of the top assembly (A). Note: Make sure
that the arrow on the cam lock fasteners in the top
assembly point toward the edge of the board. Re-
view page 3 for cam fastener instructions.
Figure 2
4. Push down on the leg assembly (B) until dowels are
fully inserted into the top assembly and there is no
gap between leg and top assembly. Using a Phillips
screwdriver, turn the cam lock fasteners clockwise
up to 1/2 turn or until resistance is felt. Do not over-
tighten, as too much torque can break the cam lock
fastener.
5. Repeat Steps 2 and 3 for the right leg assembly (C).
2. Rotate the mantel into the upright position, (requires
two people): Rotate the mantel down onto its back
by holding onto BOTH mantel legs. Then, grasp the
top assembly and lift/rotate the mantel up until it is
standing upright on both mantel legs .
Figure 4
1. Locate studs in the wall behind the appliance. At-
tach ledger board to a minimum of two studs using
3" screws (O) at a height of 48-7/8" from the oor to
the top of the ledger board. See Figure 4.
Figure 5
3. Place mantel in front of appliance spaced approxi-
mately 6 in. from the wall. Insert top trim board (D)
into the slot located on the backside of the mantel
top assembly. See Figure 5. Insert side trim boards
(E) into the slot located on the back side of the man-
tel leg See Figure 6.
Note: If using a hearth that ts between the leg
opening, cut the trim boards to allow for hearth thick-
ness between legs.
1. Locate studs in the wall behind the appliance. At-
tach wall bracket to a minimum of two studs using 3"
screws (O) at a height of 33-3/4 in. from the oor to
the top of the wall bracket. See Figure 3.
33-3/4 in
(875 mm)
Figure 3
2. Hang appliance onto the wall bracket and secure the
appliance to a minimum of two studs with 3” screws
(O) using the pre-cut holes in the component cavity.
(A)
(B)
Appliance Mounting
Preparing Mantel
(Q)
(O) x 2
(min.)
(F)
(D)
PRE-CUT
HOLES
T-10
T-10
7
SimpliFire • Wescott Mantel Kit Instruction Manual • 4200-935 • 1/23
SCREW INTO LEDGER BOARD
Figure 7
1. Move the mantel tightly against the wall while view-
ing it from all sides to make sure everything is tting
properly and that visible portions of the trim boards
are equal. The inner edge of the mantel trim boards
will overlap the outer edge of the appliance. Check
the outer edge of the mantel where it ts against the
wall to see that there is no excessively large gaps.
Small gaps will be lled later with caulk.
SimpliFire, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.hearthnhome.com
2. Secure mantel to ledger board using three 3" screws
(O) through the top edge of the mantel. Fill holes
with appropriate ll if desired. See Figure 7.
3. Attach the scribe (G,H), make sure its pushed back
against trim facing. Nail with nishing nails (P), top
assembly (G) rst. Be careful not to hit the trim as
you nail the scribe in place. Protect the trim with a
piece of corrugated cardboard held or taped be-
tween stone and hammer as you nail. Use a nail
set to set the nail head below surface of scribe, and
ll the resulting hole with an appropriate ller. See
Figure 8.
Steps 3 & 4 Optional (suggested when using other
trim facing less than 3/4” thickness in place of
supplied trim boards)
Figure 8
4. If using a hearth that ts between the leg opening,
cut the scribe to allow for stone height between the
legs. Place the scribe molding as shown, positioning
it so that it just contacts the noncombustible sur-
round. Be careful not to hit the facing material when
nailing the scribe in place. No cutting is needed if
hearth exceeds mantel legs.
Connecting to Power
Make sure the appliance is installed acoording to local
codes.
Option 1: Using an outlet located within designated cut
out in replace cavity.
See Electrical Outlet locations on page 4.
Refer to appliance manual for wiring instructions.
Option 2: Using an outlet located outside of mantel:
Pass stripped end of cord through drilled hole in
mantel and pass end of cord through hole inside of
appliance cavity.
Secure cord with strain relief (S).
Refer to appliance manual for wiring instructions.
Figure 6
(H)
(H)
(G)
Securing and Finishing Mantel
(E)
(E)
T-10
(O) x 3
(P) x 9
/