Sanyo 36KS82 User manual

Category
Split-system air conditioners
Type
User manual

This manual is also suitable for

KS3082
KS3682
COOL/DRY Model
© SANYO 2010
Pub. OI-85264181150000
INSTRUCTION MANUAL
Inverter-Controlled Split System Air Conditioner
MODE D’EMPLOI
Climatiseur de type séparé contrôlé par inverseur
This air conditioner uses
the new refrigerant R410A.
Save These Instructions!
Conserver ce mode d’emploi
00_KHS3682_Cover.fm Page 1 Tuesday, December 15, 2009 10:33 AM
2
FEATURES
This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below;
refer to these descriptions when using the air conditioner.
Microprocessor Controlled Operation
The interior compartment of the remote control unit
contains several features to facilitate automatic operation,
easy logically displayed for easy use.
Simple One-touch Wireless Remote Control
The remote control unit has several features to facilitate
automatic operation.
24-Hour ON or OFF Timer
This timer can be set to automatically turn the unit on or off
at any time within a 24 hour period.
1-Hour OFF Timer
This timer can be set to automatically turn off the unit at
any time after one hour.
•Night Setback
This function saves energy by controlling operation to
provide a quieter operating sound than normal.
Automatic and 3-step Fan Speed
Auto/High/Medium/Low
Air Sweep Control
This function moves a flap up and down in the air outlet,
directing air in a sweeping motion around the room and
providing comfort in every corner.
Auto. Flap Control
This automatically sets the flap to the optimum position
during cooling and drying operation.
Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed
operation can be reactivated once power resumes.
High Power Operation
The unit operates at maximum output for 30 minutes,
regardless of the desired temperature.
The fan speed is 1 step above “High”.
Quiet Operation
The fan rotates slower than the fan speed setting to provide
a quieter operating sound.
LED Clean Operation
During operation, the UV anti-bacteria unit is activated for
30 minutes and cleans the air blown from the air
conditioner.
Anti-Mold Filter
This unit is equipped with an anti-mold filter that inhibits the
growth of mold and bacteria.
Air Clean Filter
An air filter that eliminates unpleasant odors and cleans the
air is available.
Purchase a replacement filter at your local dealer.
(model STK-FDXB)
Unoccupied
This function prevents the room temperature from
increasing too much when no one is in the room, and
operate automatically to save energy.
CONTENTS
Page Page
FEATURES................................................................................. 2
PRODUCT INFORMATION........................................................ 3
ALERT SYMBOLS...................................................................... 3
INSTALLATION LOCATION........................................................ 3
ELECTRICAL REQUIREMENTS ............................................... 3
SAFETY INSTRUCTIONS.......................................................... 3
NAMES OF PARTS .................................................................... 4
USING THE REMOTE CONTROL UNIT.................................... 8
OPERATION WITH THE REMOTE CONTROL UNIT ................ 9
1. Operation .................................................................... 9
2. Adjusting the Fan Speed............................................. 9
3. Fan Only...................................................................... 9
4. Night Setback Mode.................................................. 10
5. QUIET Mode ............................................................. 10
6. HIGH POWER Mode................................................. 10
7. LED CLEAN Mode .................................................... 11
8. UNOCCUPIED Mode................................................ 11
SPECIAL REMARKS ................................................................12
SETTING THE TIMER ..............................................................12
USING THE 1-HOUR OFF TIMER ...........................................14
TIPS FOR ENERGY SAVING ...................................................14
ADJUSTING THE AIRFLOW DIRECTION ...............................14
OPERATION WITHOUT THE REMOTE CONTROL UNIT .......15
CARE AND CLEANING ............................................................15
TROUBLESHOOTING ..............................................................17
OPERATING RANGE................................................................17
WIRED REMOTE CONTROLLER ............................................17
OI-150-2-EG
01_KS3682_EN.fm Page 2 Friday, February 12, 2010 12:26 PM
3
PRODUCT INFORMATION
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of
the cabinet.
Model No. __________________________________
Serial No. ___________________________________
Date of purchase _____________________________
Dealer’s address _____________________________
Phone number________________
ALERT SYMBOLS
The following symbols used in this manual, alert you
to potentially dangerous conditions to users, service
personnel or the appliance:
INSTALLATION LOCATION
We recommend that this air conditioner be installed
properly by qualified installation technicians in
accordance with the Installation Instructions
provided with the unit.
Before installation, check that the voltage of the electric
supply in your home or office is the same as the voltage
shown on the nameplate.
Avoid:
To protect the air conditioner from heavy corrosion, avoid installing
the outdoor unit where salty sea water can splash directly onto it or
in sulphurous air near a spa.
ELECTRICAL
REQUIREMENTS
1. All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
2. Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
3. Wiring must be done by a qualified electrician.
SAFETY INSTRUCTIONS
Read this Instruction Manual carefully before using
this air conditioner. If you still have any difficulties
or problems, consult your dealer for help.
This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.
This symbol refers to a hazard or unsafe
practice which can result in severe
personal injury or death.
This symbol refers to a hazard or unsafe
practice which can result in personal
injury or product or property damage.
Do not install this air conditioner
where there are fumes or flammable
gases, or in an extremely humid space
such as a greenhouse.
Do not install the air conditioner where
excessively high heat-generating
objects are placed.
CAUTION
Never use or store gasoline or other
flammable vapor or liquid near the air
conditioner — it is very dangerous.
This air conditioner has no ventilator
for intaking fresh air from outdoors.
You must open doors or windows
frequently when you use gas or oil
heating appliances in the same room,
which consume a lot of oxygen from
the air. Otherwise there is a risk of
suffocation in an extreme case.
Do not turn the air conditioner on and
off from the power mains switch. Use
the ON/OFF operation button.
Do not stick anything into the air outlet
of the outdoor unit. This is dangerous
because the fan is rotating at high
speed.
Do not let children play with the air
conditioner.
Do not cool the room too much if
babies or invalids are present.
CAUTION
OI-150-3-EG
01_KS3682_EN.fm Page 3 Friday, February 12, 2010 12:26 PM
4
NAMES OF PARTS
This illustration is based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner
which you have selected.
This air conditioner consists of an indoor unit and an outdoor unit.
You can control the air conditioner with the remote control unit.
UNIT DISPLAY AND OPERATION
BUTTON
Avoid using radio equipment such as mobile phone near (within
4 ft. (1.2 m)) the remote control receiver. Some radio equipment
may cause malfunction of the unit.
If the trouble happens, disconnect power and restart the air
conditioner after a few minutes.
The unit’s display lamps are dimmed during operation in the NIGHT
SETBACK mode.
Air Intake
Air from the room is drawn into this section and
passes through air filters which remove dust.
Air Outlet
Conditioned air is blown out of the air
conditioner through the air outlet.
Remote
Control Unit
The wireless remote control unit controls power
ON/OFF, operation mode selection,
temperature, fan speed, timer setting, and air
sweeping.
Refrigerant
Tubes
The indoor and outdoor units are connected by
copper tubes through which refrigerant gas
flows.
Drain Hose
Moisture in the room condenses and drains off
through this hose.
Outdoor
(Condensing)
Unit
The outdoor unit contains the compressor, fan
motor, heat exchanger coil, and other electrical
components.
INDOOR UNIT
Air intakes
Remote control unit
Refrigerant tubes
Drain hose
OUTDOOR UNIT
Air outlet
Air outlet
NOTE
REMOTE
CONTROL
receiver
This section picks up infrared signals from the
remote control unit (transmitter).
OPERATION
button
When the remote control unit cannot be used,
pressing this button enables cooling operation.
Each time this button is pressed, the operation
mode changes cyclically.
OPERATION
lamp
This lamp lights when the system is in the
continuous DRY (orange), COOL (green) and
FAN (green) mode.
TIMER lamp This lamp lights when the system is being
controlled by the timer.
LED CLEAN
lamp
This lamp lights during operation in the UV anti-
bacterial mode.
REMOTE CONTROL
receiver
TIMER lamp
OPERATION lamp
OPERATION button
(ON/OFF)
INDOOR UNIT
LED CLEAN lamp
IMPORTANT
Cooling operation
Stop
NOTE
OI-150-4-EG
01_KS3682_EN.fm Page 4 Friday, February 12, 2010 12:26 PM
5
REMOTE CONTROL UNIT (DISPLAY)
(1) Operation mode
MILD DRY ..............................
COOL.....................................
FAN ........................................
(2) Fan speed
Automatic operation ...............
HIGH .....................................
MEDIUM.................................
LOW.......................................
(3) Temperature setting
60–8F
When set to 80 °F
temperature indication............
(4) Timer
24-hour clock with ON/OFF
program Timer .......................
ON Timer. ..............................
OFF Timer. ............................
1-hour OFF Timer. .................
(5) NIGHT SETBACK..................
(6) Confirmation of transmission.......
(7) Auto. flap indication................
Flap angle indication..............
Sweep indication....................
(8) High power operation.............
(9) UNOCCUPIED ......................
(10) Quiet operation ....................
(11) LED CLEAN operation.........
Displayed when setting timer
Displayed when transmitting data
Displayed when indoor unit sensor is
in use
Displayed when setting temperature
Displayed when temperature is shown
Symbols
OI-150-5-EG
01_KS3682_EN.fm Page 5 Friday, February 12, 2010 12:26 PM
6
REMOTE CONTROL UNIT
Transmitter
When you press the buttons on the remote control unit, the mark appears in
the display to transmit the setting changes to the receiver in the air conditioner.
Display
Information on the operating conditions is displayed while the remote control unit
is switched on. If the unit is turned off, FLAP setting and FAN SPEED setting are
not displayed.
FAN SPEED selector button
: The air conditioner automatically decides the fan speeds.
: High fan speed
: Medium fan speed
: Low fan speed
FLAP button
Press this button either to select the setting of the airflow direction to the
auto. flap in each mode or one of the six possible positions manually or to
select the sweep function which moves the flap up and down automatically.
: Auto flap setting: If selected in a cooling or dry operation, the flap is
set at position (7) in the following chart.
: The airflow direction can be set manually. (six positions)
: The flap moves up and down automatically.
When you press the FLAP button, the air flow direction will be changed one
by one as follows.
NOTE
SWEEP
CANCEL button
SENSOR button
When you press this button (use a small-tipped object such as a ballpoint pen), the
mark will appear at the display. And the room temperature is detected by the
sensor which is built into the indoor unit and the air conditioner is controlled
accordingly.
If the remote control unit is located near a heat source, such as a space heater or in
direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.
NOTE
LED CLEAN button
: If this button is pressed during DRY, COOL or FAN operation, the UV
anti-bacterial unit is activated for 30 minutes and cleans the air blown
from the air conditioner.
ADDRESS switch
The address switch changes to prevent mixing of signals from remote control units when two
air conditioners are installed next to each other. Normally, the address switch is set to A. For
more information, please contact the dealer where you made the purchase.
Normally, the tabs on the remote control unit should not be bent.
Temperature display selector button
This switches the temperature display
between °C and °F.
QUIET button
: When you press this button, the fan rotates slower than the fan speed
setting to provide a quieter operating sound.
ON TIME/OFF TIME setting buttons
Advance button
Return button
No display: The timer does not operate.
: The air conditioner starts at the set time.
: The air conditioner stops at the set time.
: The air conditioner stops and starts, or starts
and stops, at the set times every day. For
details, see “SETTING THE TIMER”.
OI-150-6-EG
01_KS3682_EN.fm Page 6 Friday, February 12, 2010 12:26 PM
7
Sensor
A temperature sensor inside the remote control unit senses the room
temperature.
(Cover closed)
CLOCK button
ACL button (ALL CLEAR)
Puts the remote control unit into pre-operation status. Always press this button
after replacing the batteries.
ON/OFF operation button
This button is for turning the air conditioner on and off.
1 HR. TIMER button (1-HOUR OFF TIMER)
: When you press this button, regardless of whether the unit is operating
or stopping, the unit operates for one hour and then shuts down.
Temperature setting buttons (TEMP.)
Press the button to increase the set temperature.
Press the button to reduce the set temperature.
The temperature setting changes by 1 °C or 2 °F each time one of the TEMP.
buttons is pressed.
MODE selector button
Use this button to select DRY, COOL or FAN mode.
(DRY) : The air conditioner reduces the humidity in the room.
(COOL) : The air conditioner makes the room cooler.
(FAN) : The air conditioner works only as a circulation fan.
NIGHT SETBACK button
For details, see “4. Night Setback Mode”. When you press this button in the
DRY or COOL mode, the mark appears in the display, and the remote
control unit will automatically adjust the set temperature to save energy.
HIGH POWER button
: If this button is pressed during DRY, COOL or FAN operation, the unit
operates at maximum output for 30 minutes, regardless of the desired
temperature.
The fan speed is 1step above ‘‘HIGH’’.
UNOCCUPIED button
For details, see “8. UNOCCUPIED Mode”. When you press this button, the
mark appears in the display. And the remote control unit will automatically
prevent the room temperature from increasing too much when no one is in the
room.
The illustration above pictures the remote control unit after the cover has been opened.
The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the
remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will
switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the
temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.
The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is
reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.
NOTE
OI-150-7-EG
01_KS3682_EN.fm Page 7 Friday, February 12, 2010 12:26 PM
8
USING THE REMOTE CONTROL UNIT
HOW TO INSTALL BATTERIES
1. Slide the cover in the direction indicated by the arrow and remove
it.
2. Install two AAA alkaline batteries. Make sure the batteries point in
the direction marked in the battery compartment.
3. Use a thin object such as the tip of a pen to press the ACL button.
The batteries last about six months, depending on how much
you use the remote control unit. Replace the batteries when
the remote control unit’s display fails to light, or when the
remote control unit cannot be used to change the air
conditioner’s settings.
Use two fresh leak-proof type-AAA alkaline batteries.
In replacing batteries, follow the instructions as mentioned in
the sub-section “HOW TO INSTALL BATTERIES”.
If you do not use the remote control unit more than 1 month,
take out the batteries.
Dispose of the used batteries at the designated location in
compliance with the applicable local ordinances.
HOW TO USE THE REMOTE CONTROL UNIT
When using the remote control unit, always point the unit’s
transmitter head directly at the air conditioner’s receiver.
REMOTE CONTROL UNIT INSTALLATION
POSITION
The remote control unit may be operated either from a non-fixed
position or from a wall-mounted position. To ensure that the air
conditioner operates correctly, DO NOT install the remote control
unit in the following places:
DO NOT
In direct sunlight
Behind a curtain or other places where it is covered
More than 26 ft.(8 m) away from the air conditioner
In the path of the air conditioner’s airstream
Where it may become extremely hot or cold
Where it may be subject to electrical or magnetic noise
Where there is an obstacle between the remote control unit and air
conditioner (since a check signal is sent from the remote control
unit every 5 minutes)
MOUNTING THE REMOTE CONTROL UNIT
Before mounting the remote control unit, press the ON/OFF
operation button at the mounting location to make sure that the air
conditioner operates from that location. The indoor unit should make
a beeping sound to indicate that it has received the signal.
To take out the remote control unit, pull it forward.
WHEN HOLDING THE REMOTE CONTROL UNIT
When using the remote control unit and during air conditioner
operation, the transmitter on the remote control unit should be
pointed towards the receiver on the indoor unit.
Make sure that there are no objects between the remote control
unit and receiver which could block the signal.
ACL button
NOTE
Air conditioner
(Indoor unit)
Receiver
Remote control unit
(Transmitter head)
To prevent loss of the remote control
unit, you can connect the remote
control unit to the mount by passing
a string through the remote control
unit and attachment hole.
Remote control unit mount
Mounting screws
5/32 x 5/8"
(4 x 16 mm)
(included)
Rear side
Hole
Press
Set in
place
OI-150-8-EG
01_KS3682_EN.fm Page 8 Friday, February 12, 2010 12:26 PM
9
OPERATION WITH THE REMOTE CONTROL UNIT
1. Operation 2. Adjusting the Fan Speed
A. Automatic fan speed
Simply set the FAN SPEED selector button to the
position.
This automatically sets the best fan speed for the room
temperature.
B. Manual fan speed
If you want to adjust fan speed manually during operation,
just set the FAN SPEED selector button as desired. [ ,
, or ]
3. Fan Only
Check that the circuit breaker on the power panel is
turned on.
Press the setting buttons as described below and
change the settings as desired.
STEP 1 Press the MODE selector button
and select the desired mode.
For dehumidifying operation
For cooling operation
For fan only operation
STEP 2 To start the air conditioner, press the ON/
OFF operation button.
STEP 3 Press the TEMP. setting buttons to change
the temperature setting to the desired
temperature.
Adjustable temperature range:
STEP 4 Set the FAN SPEED selector button to the
setting you want.
STEP 5 Press the FLAP button and set the airflow
direction as desired.
(Refer to “ADJUSTING THE AIRFLOW
DIRECTION” on page 14.)
To stop the air conditioner, press the ON/OFF
operation button again.
Choose the best position in the room for the remote
control unit, which also acts as the sensor for room
comfort and transmits the operating instructions.
Once you’ve found this best position, always keep the
remote control unit there.
This appliance has a built-in 5-minute time delay
circuit to ensure reliable operation. When the
operation button is pressed, the compressor will start
running within three minutes. In the event of power
failure, the unit will stop.
STEP 2
STEP 1
STEP 3
STEP 4
STEP 5
NOTE
30 °C max.
16 °C min.
or 86 °F max.
60 °F min.
NOTE
If you want to circulate air without any temperature
control, follow these steps:
STEP 1 Press the MODE selector button to switch to
the fan mode .
STEP 2 Press the ON/OFF operation button.
STEP 3 Press the FAN SPEED selector button to
select the fan speed of your choice ( ,
or ).
STEP 2
STEP 1
STEP 3
OI-150-9-EG
01_KS3682_EN.fm Page 9 Friday, February 12, 2010 12:26 PM
10
4. Night Setback Mode
Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while operation. (except FAN
mode)
The mark appears in the display.
To release the night setback function, press the NIGHT SETBACK
button again.
Pressing the MODE selector button cancels Night Setback mode.
In Cooling and DRY Mode: ( and )
5. QUIET Mode
QUIET Mode is used to reduce the fan sound of the indoor unit.
Press the QUIET button.
The mark appears in the display.
To cancel, press QUIET button again.
In QUIET Mode, the fan rotates at a slower speed than the fan
speed setting.
If the unit is already operating with a very low airflow, the fan sound
may not change even if the QUIET button is pressed.
6. HIGH POWER Mode
HIGH POWER mode can be used to increase the output of the
indoor unit for all operation modes.
Press the HIGH POWER button while operation.
The mark appears in the display.
To cancel, press HIGH POWER button again.
When the HIGH POWER button is pressed, the unit operates at
maximum output for 30 minutes, regardless of the desired
temperature. The fan speed is 1 step above “High”.
QUIET Mode and HIGH POWER Mode cannot be used at the
same time.
Pressing the MODE selector button cancels HIGH POWER mode.
Depending on the operating conditions, the fan speed may be
increased by a small amount only.
NOTE
When the night setback mode is selected, the air conditioner
automatically raises the temperature setting 2 °F when 30 minutes
have passed after the selection was made, and then another 2 °F
after another 30 minutes have passed, regardless of the indoor
temperature when night setback was selected. This enables you
to save energy without sacrificing comfort. This function is
convenient when gentle cooling is needed.
Setting
temperature
Press the NIGHT
SETBACK button
30 min.
30 min.
Time
F
F
NOTE
OI-150-10-EG
01_KS3682_EN.fm Page 10 Friday, February 12, 2010 12:26 PM
11
7. LED CLEAN Mode
In LED CLEAN mode, a UV anti-bacterial unit (including a LED
CLEAN lamp and anti-bacterial filter) in the indoor unit is used during
DRY, COOL, or FAN operation to remove bacteria from air blown
from the air conditioner.
Press the LED CLEAN button while operation.
The mark appears in the display.
To cancel, press the LED CLEAN button again.
When the LED CLEAN button is pressed, the UV anti-bacterial unit
operates for one hour and cleans air blown from the air conditioner.
Pressing the MODE selector button cancels LED CLEAN mode.
Do not open the front panel while the LED CLEAN lamp on the
display is on.
Depending on the room brightness, light from the LED CLEAN
lamp may reflect inside the air conditioner and be visible. This is
not a malfunction.
8. UNOCCUPIED Mode
Unoccupied mode is used to prevent the room temperature from
increasing too much when no one is in the room, and operate
automatically to save energy.
Press the UNOCCUPIED button.
The mark appears in the display.
To release the unoccupied function, press the UNOCCUPIED button
again.
Unoccupied Indication
Even if Unoccupied Mode is ON, it will be disabled if the air
conditioner is in operation.
Unoccupied Function can be set and released through all
operational modes, regardless of whether the air conditioner is
operating or not.
If the Unoccupied Function is ON and the remote control unit is
used to turn the air conditioner OFF (including OFF TIMER), the air
conditioner will turn off, but depending on the room temperature,
Cooling Operation will automatically begin.
When the Unoccupied Function is in operation and the ON/OFF
operation button is pressed, operation will restart based on the
settings input before the air conditioner was turned off.
In Cooling Mode: ( )
Unoccupied Mode triggers Cooling Operation in response to the
room temperature, but when this happens, the remote control unit
will continue to display the Operation mode set by the user.
If the room temperature rapidly changes, the room temperature
may get over the upper or lower limit when the unoccupied function
is activated.
The remote control unit should be used in the location specified in
“REMOTE CONTROL UNIT INSTALLATION POSITION” on
page 8.
The air conditioner’s stop order (stated in (2) / above) is valid only
when the unoccupied function is operated.
NOTE
Unoccupied
Function
Unoccupied
Indication
Status
OFF no display The unoccupied function is not set.
ON
flashing
The unoccupied function is now
being set, and under Cooling
operation.
lighting
Although the unoccupied function is
set, not under Cooling operation.
NOTE
(1)
89
86
82
(2)
Room
Temperature (°F)
Cooling
starts
Time
Cooling
stops
(1) When the room temperature rises above 89°F, Cooling
Operation will begin.
(2) When the room temperature drops below 82°F, Cooling
Operation will stop.
The above actions will repeat so that the room temperature is
maintained at about 86°F.
NOTE
OI-150-11-EG
01_KS3682_EN.fm Page 11 Friday, February 12, 2010 12:26 PM
12
SPECIAL REMARKS
How it works?
Once the room temperature reaches the level that was set, the
unit’s operation frequency is changed automatically.
During DRY operation, the fan speed automatically runs at lower
speed for providing a comfortable breeze.
‘DRY’’ operation is not possible if the indoor temperature is 59 °F
or less.
Sometimes the indoor unit may not get to the set fan speed such as
LOW under cool operation at very low outdoor temperatures due to
the indoor unit being protected from ice or frost.
In the event of power failure, the unit will stop. When the power is
resumed, the unit will restart automatically in approximately
5 minutes by the remote control unit.
If the remote control unit is on and left in a location where the unit
can receive a signal, then the unit will automatically restart in
approximately 5 minutes of power being restored.
Clicking sound is heard from the air conditioner
In cooling operation, any plastic parts may shrink due to a sudden
temperature change. In this event, a clicking sound may occur. This
is normal, and the sound will soon disappear.
The remote control unit sends the setting condition to the air
conditioner regularly at five minute intervals.
SETTING THE TIMER
In the descriptions below, the following settings are used for the
temperature and time indicator selector button on the bottom front
section of the remote control unit.
Temperature: °F
Time: AM, PM
1. How to set the present time
(Example) To set to 10:30 pm.
‘DRY’’ ( ) Operation
Cooling ( ) operation
Power failure during operation
Clicking Sound
Remote Control Unit
Operation Indication
1. Press the CLOCK button
once if the time indicator is
not flashing.
The time indication alone
flashes.
2. Press the Advance, Return
( , ) button until PM 10:30
is displayed.
The time can be set in 1-minute
increments. Holding down the
button advances the time rapidly
in 10-minute increments.
3. Press the CLOCK button
again.
This completes the setting of the
current time.
NOTE
OI-150-12-EG
01_KS3682_EN.fm Page 12 Friday, February 12, 2010 12:26 PM
13
2. How to set the OFF time
(Example) To stop the air conditioner at 11:00 am.
3. How to set the ON time
(Example) To start operation at 7:10 am.
4. How to set daily ON/OFF repeat timer
(Example) To start operation at 7:10 am. and stop the air conditioner
at 11:00 am.
The ON/OFF combination timer uses the current time as the
reference, and it is activated starting from whichever set time
comes first.
With the ON/OFF combination timer, the settings are repeated
every day.
You can check the timer ON/OFF times after you have set them by
pressing the ON TIME and OFF TIME setting buttons.
To cancel a timer program
Press the CANCEL button.
When either an ON or OFF timer is to be canceled, press the
button corresponding to the timer whose program is to be
canceled, and then press the CANCEL button.
The airflow direction, fan speed and temperature setting can be
changed after a timer program has been set even when the unit is
stopped. Even when operation is stopped during an ON timer
program, the unit will start operating when the set time is reached
provided that the program is not canceled.
When the ON timer and OFF timer are set to the same time, the
timer operates as if it is turned off.
Operation Indication
1. Press the OFF TIME setting
button once.
The timer indication is
displayed, and the present OFF
time is shown.
2. Press the Advance, Return
( , ) button until AM 11:00
is displayed.
The timer indication
blinks.
The time can be set in 10-minute
increments. Holding down the
button advances the time rapidly
in 10-minute increments.
3. Wait a few seconds, and then
the setting is complete.
The timer indication
stops blinking and the present
time is displayed.
Operation Indication
1. Press the ON TIME setting
button once.
The timer indication is
displayed, and the present ON
time is shown.
2. Press the Advance, Return
( , ) button until AM 7:10
is displayed.
The timer indication
blinks.
The time can be set in 10-minute
increments. Holding down the
button advances the time rapidly
in 10-minute increments.
3. Wait a few seconds, and then
the setting is complete.
The timer indication
stops blinking and the present
time is displayed.
Operation Indication
1. Set the timer ON/OFF times
as shown in 2-1, 2, 3 and 3-1,
2, 3.
The present time 10:30 pm. and
are displayed.
7:10 am.
ON
11:00 am.
OFF
10:30 pm.
Present time
NOTE
NOTE
OI-150-13-EG
01_KS3682_EN.fm Page 13 Friday, February 12, 2010 12:26 PM
14
USING THE 1-HOUR OFF
TIMER
1. 1-Hour OFF Timer
This function causes the unit to operate for one hour and then
stop, regardless of whether the unit is on or off when this
button is pressed.
The indicator in the display indicates that this function is
operating.
Setting procedure:
Regardless of whether the unit is operating or stopped, press the 1
HR. TIMER button.
appears in the display.
Cancellation procedure:
Press the ON/OFF operation button to turn the unit off, wait for the
unit to stop operating, and then press the ON/OFF operation button
again.
The 1-Hour Timer function is now cancelled and the unit operates
normally.
If, while the 1-Hour Timer function is operating, the 1HR. TIMER
button is pressed once to cancel the function and then again, the
unit continues to operate for one hour from that point in time and
then stops.
It is not possible to use the OFF Timer and 1-Hour OFF Timer
together. Whichever function is set last takes precedence. If the 1
HR. TIMER button is pressed while the TIMER OFF function
operates, the OFF Timer is cancelled and the unit will stop
operating one hour later.
2. Operation together with the daily ON/OFF
repeat timer
The 1-Hour OFF Timer setting is given priority over the DAILY ON/
OFF REPEAT setting.
TIPS FOR ENERGY SAVING
Do not
Block the air intake and outlet of the unit. If they are
obstructed, the unit will not work well, and may be damaged.
Let direct sunlight into the room. Use sunshades, blinds or curtains.
If the walls and ceiling of the room are warmed by the sun, it will
take longer to cool the room.
Do
Always try to keep the air filter clean. (Refer to “CARE AND
CLEANING”.) A clogged filter will impair the performance of the
unit.
To prevent conditioned air from escaping, keep windows, doors and
any other openings closed.
ADJUSTING THE AIRFLOW
DIRECTION
1. Horizontal
The horizontal airflow can be adjusted by moving the vertical vanes
with your hands to the left or right.
When the humidity is high, the vertical vanes should be in the
front position during the cooling or dehumidifying operation. If
the vertical vanes are positioned all of the way to the right or
left, condensation may begin to form around the air vent and
drip down.
2. Vertical
The vertical airflow can be adjusted by moving the flap with the
remote control unit. Do not move the flap with your hands. Confirm
that the remote control unit has been turned on. Use the FLAP
button to set either the sweep function or one of the six airflow
direction settings.
The flap automatically closes when the unit is off.
NOTE
CAUTION
FAN
SWEEP
SWEEP
A. Sweep function
The flap starts moving
up and down to deliver
air over the sweep
range.
B. Setting the airflow manually
Referring to the above
illustration, use the
FLAP button to set the
airflow direction within
the range used during
cooling or
dehumidifying
operation.
C. Auto flap function
The flap is set
to the
recommended
position.
COOL
DRY
NOTE
OI-150-14-EG
01_KS3682_EN.fm Page 14 Friday, February 12, 2010 12:26 PM
15
Use the FLAP button on the remote control to adjust the
position of the flap. If you move the flap by hand, the flap
position according to the remote control and the actual flap
position may no longer match. If this should happen, shut off
the unit, wait for the flap to close, and then turn on the unit
again; the flap position will now be normal again.
Do not have the flap pointed down during cooling operation.
Condensation may begin to form around the air vent and drip
down.
OPERATION WITHOUT THE
REMOTE CONTROL UNIT
If you have lost the remote control unit or it has trouble, follow the
steps below.
When the air conditioner is not running
Each time the OPERATION button is pressed, the operation mode
changes cyclically.
The temperature is set to the room temperature minus 4°F during
the cooling operation, and the fan speed and flap are set to Auto.
CARE AND CLEANING
Casing and Grille (Indoor Unit)
Clean the casing and grille of the indoor unit with a vacuum cleaner
brush, or wipe them with a clean, soft cloth.
If these parts are stained, use a clean cloth moistened with a mild
liquid detergent. When cleaning the grille, be careful not to force the
vanes out of place.
Anti-Mold Filter
The anti-mold filter behind the front panel should be checked and
cleaned at least once every two weeks.
How to remove the anti-mold filter
1.
Grasp both ends of the front panel and pull forward and up to
open the front panel.
2. Lift the anti-mold filter up slightly to disengage it from the
protrusions on the unit.
3. Pull downward to remove the filter from the unit.
Cleaning
Use a vacuum cleaner to remove light dust. If there is sticky dust on
the filter, wash the filter in lukewarm, soapy water, rinse it in clean
water, and dry it.
How to replace the anti-mold filter
1.
Insert the top of the anti-mold filter, and then secure the bottom of
the filter with the protrusions on the unit.
2. Close the front panel by pushing the center of the front panel and
then pressing both edges until the panel clicks into place.
Air Clean Filter
The air clean filter removes dust and dirt from the air, and reduces
odors and smoke from tobacco.
1. For safety, be sure to turn the air
conditioner off and also to
disconnect the power before
cleaning.
2. Do not pour water on the indoor unit
to clean it. This will damage the
internal components and cause an
electric shock hazard.
CAUTION
INDOOR UNIT
OPERATION button (ON/OFF)
OPERATION lamp
Cooling operation
Stop
NOTE
1. Never use solvents, or harsh
chemicals when cleaning the indoor
unit. Do not wipe the plastic casing
using very hot water.
2. Some metal edges and the fins are
sharp and may cause injury if
handled improperly; be especially
careful when you clean these parts.
3. The internal coil and other
components of the outdoor unit
must be cleaned every year. Consult
your dealer or service center.
CAUTION
Protrusions
Front panel
Anti-mold filter
1
2
2
OI-150-15-EG
01_KS3682_EN.fm Page 15 Friday, February 12, 2010 12:26 PM
16
How to install the air clean filter
The air clean filter needs to be installed behind the anti-mold filter.
1. Open the front panel and remove the anti-mold filter.
2. Remove the air filter holder from the anti-mold filter.
3. Install the air clean filter in the air filter holder.
4. Install the air filter holder to the anti-mold filter, remount the anti-
mold filter, and close the front panel.
How to clean the air clean filter
In general, the filter should be sucked to remove dust in low fan
speed of a vacuum cleaner once every three months.
If there is heavily grime on the filter, soak the filter in lukewarm
water with neutral detergent diluted 1:500 for 1 to 2 minutes then
wash it.
Rinse the filter in clean water, then let it dry on the towel in room
temperature.
Do not bend nor give excessive force onto the air clean filter.
If the filter surface is heavily blocked with dirt or damaged, replace
it with new one. Purchase a replacement filter at your local dealer.
(model STK-FDXB)
Cleaning the main unit and remote control unit
Wipe clean using a soft, dry cloth.
To remove stubborn dirt, moisten a cloth in warm water no hotter
than 104 °F, wring thoroughly, and then wipe.
The front panel can be removed in order to wash it with water.
Removing and remounting the front panel
Removing
Open the front panel until it is nearly horizontal, grasp the sections
near the front panel arms on both sides, and then remove the panel
by pushing the arms towards the outside while pulling the panel
towards you.
If the front panel is difficult to remove, grasp both ends of it and lift it
up slightly.
Move it to the left and disengage the left arm, then move it to the
right and disengage the right arm.
Remounting
Grasp the sections near the front panel arms on both sides, and
hold the front panel so that it is nearly horizontal. Push the arm
shafts towards the outside so that they come into contact with the
top of the indentations on the right and left sides of the air
conditioner. Then push firmly until the arm shafts click into place.
After closing the front panel, press firmly on the parts indicated by
the arrows to securely fasten the panel in place.
Also refer to the figure that shows “How to replace the anti-mold
filter”.
Washing the front panel with water
Clean the front panel gently using a soft sponge, or the like. Then
wipe away any remaining moisture.
Neutral detergent may be used to remove stubborn dirt. Then rinse
thoroughly with water and wipe away any remaining moisture.
This air clean filter cannot remove
harmful gases or vapors nor ventilate
air in the room. You must open doors
or windows frequently when you use
gas or oil heating appliances.
Otherwise there is a risk of suffocation
in extreme cases.
Air filter holder
Anti-mold filter
Air clean filter
NOTE
Front panel Arm
When using a footstool or the like, be
careful not to let it tip over.
CAUTION
OI-150-16-EG
01_KS3682_EN.fm Page 16 Friday, February 12, 2010 12:26 PM
17
TROUBLESHOOTING
If your air conditioner does not work properly, first check the following
points before requesting service. If it still does not work properly,
contact your dealer or service center.
OPERATING RANGE
The air conditioner is operable within the temperature ranges as
listed below:
WIRED REMOTE CONTROLLER
A separately sold wired remote controller (STK-RCS-
7TWSUA) used with this air conditioner is also available. If
you wish to use the wired remote control function, you will
need to purchase both the optional wired remote controller
and its connection kit (STK-KCW2).
Trouble Possible Cause Remedy
Air conditioner does
not run at all.
1. Power failure. 1. Restore power.
2. Leakage circuit
breaker tripped.
2. Contact service
center.
3. Line voltage is too
low.
3. Consult your
electrician or
dealer.
4. Batteries in remote
control unit have
run down.
4. Replace batteries.
OPERATION lamp
blinks and air
conditioner does not
operate.
Trouble in system. Contact service
center.
Compressor runs but
soon stops.
Obstruction in front of
condenser coil.
Remove obstruction.
Poor cooling
performance.
1. Dirty or clogged air
filter.
1. Clean air filter to
improve airflow.
2. Heat source or
many people in
room.
2. Eliminate heat
source if possible.
3. Doors and/or
windows are open.
3. Shut them to keep
the heat out.
4. Obstacle near air
intake or air
discharge port.
4. Remove it to
ensure good
airflow.
5. Thermostat is set
too high for
cooling.
5. Set the
temperature lower.
Clicking sound is
heard from the air
conditioner.
In cooling operation,
any plastic parts may
shrink due to a
sudden temperature
change. In this event,
a clicking sound may
occur.
This is normal, and
the sound will soon
disappear.
OPERATION lamp
lights but outdoor unit
will not run.
The use of cellular
phones near the air
conditioner may
cause disturbance to
its normal operation.
1. Turn off the power
then restart the air
conditioner after a
while.
2. Consult your
dealer.
Temperature Indoor air
temperature
Outdoor air
temperature
COOLING Max. 95 °F DB /
71 °F WB
115 °F DB
Min. 67 °F DB /
57 °F WB
0 °F DB
OI-150-17-EG
01_KS3682_EN.fm Page 17 Friday, February 12, 2010 12:26 PM
SANYO North America Corporation
Commercial Solutions Division
2055 Sanyo Ave., San Diego
CA 92154, U.S.A.
In Canada
SANYO Canada Inc.
201 Creditview Road, Woodbridge
Ontario, L4L 9T1, Canada
End.fm Page 32 Tuesday, December 15, 2009 2:18 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Sanyo 36KS82 User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages