Haws 1105 Installation guide

Type
Installation guide
6"
152mm
*41-1/2"
1054mm
FLOOR LINE
WALL FACE
(BY OTHERS)
3/8" O.D SUPPLY
MOUNTING PLATE
(OPTIONAL)
*38-1/8"
956mm
914mm
*36-1/2"
SUPPLY STOP AND
6700
WASTE (BY OTHERS)
1/2" IPS
SUPPLY
1-1/4" IPS TRAP
(SUPPLIED)
(BY OTHERS)
12"
305mm
(W/OPT
2-1/8"
54mm
1/2"
12.7mm
BACK PANEL)
MOUNTING PLATE
(OPTIONAL, HAWS 6700)
UP FTN SIDE
872mm
*34-5/16"
127mm
5"
406mm
16"
15"
381mm
227mm
9"
MOUNTING DETAIL
83mm
3-1/4"
SUPPLY
70mm
2-3/4"
875mm
BACK PANEL OPTIONAL ON 1105
TO FLOOR
83mm
3-1/4"
*34-7/16"
130mm
5-1/8"
WASTE
C
MOUNTING
9.5mm
Ø
SLOTS
3/8"
BACK PANEL STANDARD ON 1105BP
12-1/4"
310mm
(TO SPOUT OUTLET)
NOTES:
3
1. HOLD ROUGH-IN DIMENSIONS ± 1/4" (6.4mm).
2. WHEN INSTALLING THIS UNIT LOCAL, STATE OR FEDERAL CODES SHOULD BE
ADHERED TO. FOR INSTALLATION HEIGHTS OTHER THAN SHOWN, DIMENSIONS
MARKED (*) MUST BE ADJUSTED ACCORDINGLY.
3 REFER TO 5874 SERIES OPERATION AND MAINTENANCE MANUAL FOR PUSH
BUTTON AND VALVE INSTALLATION/MAINTENANCE INSTRUCTIONS.
L
APPROVED:
DRAWN:
PART NUMBER
SCALE:
SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
F. VASQUEZ
12/97
17
0002076524.D
1105/1105BP
NA
11
FV
07/06/17
VWC
INSTALLATION
5124
2017
VWC
  • Page 1 1

Haws 1105 Installation guide