17602168
Gas Fireplace
Framing Guide
2020
Models
21 TRV 3615 HO ProBuilder 42 Linear ProBuilder 24 CF
564 TRV 25K 4415 HO ProBuilder 54 Linear ProBuilder 36 CF
564 TRV 25K CF 4415 HO ST ProBuilder 72 Linear ProBuilder 42 CF
564 HO 6015 HO
864 TRV 31K 4237 Clean Face
864 TRV 31K CF
854 ST
NOTE: FOR GENERAL REFERENCE ONLY.
Always consult the product installation manual
for detailed installation information.
Manuals can be found at
www.fireplacex.com
or
by scanning the
QR code on each page
Page | 2
21TRV
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
35-7/8"
(912mm)
(204mm)
(216mm)
(124mm)
(102mm)
8" External Diameter
1
3
-
5
/
8
"
*
45°
20-1/8"
See "Gas Line
Requirements" for
Details on the Gas Inlet
7
-
1
/
2
"
*
4-7/8"
Nailing Brackets
4"
Nailing
Bracket
(Framing
)
27-1/4"
Rear Vent Configuratio
n
8-1/2"
12-3/8"*
Top Vent Configuratio
n
Lifting Bracket (may
be bent down)
34-1/8"
(867mm)
(512mm)
(693mm)
(315mm)
(
1
9
1
m
m
)
(
3
4
6
m
m
)
* See "Clearances" and "Framing Dimensions" for details.
NOTE: 1/2" clearance is required to the angled sides and rear of the fireplace.
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
Raised
Platform
Optional Hearth
Minimum
57"
(1448mm)
Ceiling
If using an elbow directly off the
fireplace, the vent will be centered
41-3/4" (1061mm) above the base
o
the fireplace.
20-1/4"
(515mm)
48-3/4" Min.
(1239mm)
14"
(356mm)
Firestop
(required)
Vent Clearances:
1" (26mm) to the sides, 1" (26mm) below, and 3" (77mm)
above the vent to combustibles.
34-1/4"
(870mm)
27-1/4"
(693mm)
Vent Clearances:
1" (26mm) to the sides
1" (26mm) below
3" (77mm) above
20.25"
(515mm)
(315mm)
34-1/4"
12-3/8"
Firestop
(required)
Center of Rear Vent
34-1/4" (870mm) Min.
Enclosure Height
(870mm)
Page | 3
564 TRV 25K
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
37-1/4"*
947mm
17-1/4"*
439mm
28-1/2"*
724mm
30-1/4"
768mm
1"
25mm
28-3/4"
730mm
18-7/8"
480mm
31-3/4"
794mm
Top Vent Configuration
8" (203mm) Diameter Vent
4-3/4"
121mm
32-3/4"
832mm
* Includes 1/2" (13mm) clearnance - see "Clearances" and "Framing Dimensions" for details.
L
e
f
t
a
'
g
a
u
c
h
e
F
r
o
n
t
a
v
a
n
t
R
i
g
h
t
d
r
o
i
t
R
e
a
r
a
r
r
i
e
'
r
e
37"
940mm
Lifting Handle
37-3/4"
959mm
17-1/2"
445mm
37-1/4"
947mm
MIn. Enclosure
39-1/2" 1004mm
Max. 3"
77mm
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
Rear Vent
C
on
f
iguratio
n
8" (203mm) Diameter Vent
B
a
c
k
o
f
F
i
r
e
p
l
a
c
e
24-1/4"
616mm
Page | 4
564 TRV 25K CleanFace
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
Rear Vent
C
on
f
iguratio
n
8" (203mm) Diameter Vent
B
a
c
k
o
f
F
i
r
e
p
l
a
c
e
24-1/4"
616mm
* See "Clearances" and "Framing Dimensions" for details.
31-3/4"
807mm
38-1/4"
972mm
4-3/4"
121mm
Top Vent Configuration
8" (203mm) Ø Vent
Framing Opening
L
e
f
t
a
'
g
a
u
c
h
e
F
r
o
n
t
a
v
a
n
t
R
i
g
h
t
d
r
o
i
t
R
e
a
r
a
r
r
i
e
'
r
e
Baseplate
The bottom of the face is
1/8" (4mm) above the
baseplate.
5-3/4"
147mm
19-3/4"
502mm
37"
940mm
7-5/8"
194mm
33-1/8"
842mm
32-5/8"
829mm
19-1/8" *
486mm
28-1/2"*
724mm
38-3/4"
985mm
19-3/8" 493mm Flush Install
18-7/8" 480mm Extended (Tile Over) Install
37-1/4"
947mm
MIn. Enclosure
39-1/2" 1004mm
Max. 3"
77mm
This document is for reference
purposes only. Consult the
installation manual BEFORE
makin
g
installation decisions.
Page | 5
564 HO NB
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
36-1/2"
928mm
36-3/4"
936mm
17-3/4"
451mm
56"
1423mm
a
36-1/4"
921mm
Weight: 165 Lbs. (74 kg)
18-1/4" *
464mm
28" *
712mm
30-1/4"
768mm
33-1/4"
845mm
1"
25mm
28-3/4"
730mm
18-7/8"
480mm
31-3/4"
807mm
8" (203mm) Diameter Vent
6-1/4"
159mm
32-3/4"
832mm
* See "Clearances" and "Framing Dimensions" for details.
L
e
f
t
a
'
g
a
u
c
h
e
F
r
o
n
t
a
v
a
n
t
R
i
g
h
t
d
r
o
i
t
R
e
a
r
a
r
r
i
e
'
r
e
36-1/4"
928mm
Heat Shield
(must be bent vertically after fireplace is in location)
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
(a) Minimum Enclosure Height
Page | 6
864 TRV 31K
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
30-3/4"
781mm
B
a
c
k
o
f
F
i
r
e
p
l
a
c
e
Rear Vent
C
on
f
iguration
8" (203mm) Ø Vent
Top Vent
C
on
f
iguration
8" (203mm) Ø Vent
38-1/4"
972mm
36-3/4"
933mm
41"
1041mm
20-3/4"*
528mm*
38-1/4"
972mm
28-5/8"*
728mm*
37"
940mm
35-1/4"
895mm
7-1/4"
184mm
1"
25mm
* See "Clearances" and "Framing Dimensions" for details.
Optional "CoolSmart TV" or
"Power Heat Duct" Connection
Route the electrical line to
a position to the left rear
of the fireplace.
41-1/4"
1048mm
38-1/2"
978mm
20-3/4" (528mm)
Minimum enclosure height = 38-1/2" (978mm)
Page | 7
864 TRV 31K
CleanFace
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
43"
1093mm
45"
1143mm
Min. Enclosure
48" 1220mm
22" (559mm)
Standard Facing*
22-1/2" (572mm)
Submerged Facing*
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
38-1/4"
972mm
42-3/4"
1086mm
7-1/4"
184mm
Optional "CoolSmart TV" or
"Power Heat Duct" Connection
22" *
559mm
Baseplate
The bottom of the face is
1/8" (4mm) above the
baseplate.
5-5/8"
143mm
25-7/8"
658mm
44-3/4"
1137mm
7-3/4"
197mm
39-1/4"
997mm
37"
940mm
* See "Clearances" and "Framing Dimensions" for details.
Top Vent Configuration
8" (203mm) Ø Vent
28-5/8"*
728mm*
30-3/4"
781mm
B
a
c
k
o
f
F
i
r
e
p
l
a
c
e
Rear Vent
C
on
f
iguration
8" (203mm) Ø Vent
Page | 8
864 TV 40K
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
Top Vent
C
on
f
iguration
8" (203mm) Ø Vent
38-1/4"
972mm
36-3/4"
933mm
41"
1041mm
20-3/4"*
528mm*
38-1/4"
972mm
28-5/8"*
728mm*
37"
940mm
35-1/4"
895mm
7-1/4"
184mm
1"
25mm
* See "Clearances" and "Framing Dimensions" for details.
Optional "CoolSmart TV" or
"Power Heat Duct" Connection
41-1/4"
1048mm
38-1/2"
978mm
20-3/4" (528mm)
Min. enclosure height NG = 62-3/4" (1594mm)
Min. enclosure height LP = 74-3/4" (1899mm)
a
a
Page | 9
864 TV 40K
CleanFace
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
43"
(1093mm)
45"
(1143mm)
22" (559mm) Standard Facing
(drywall contacts side of fireplace)
22-1/2" (572mm) Submerged Facing
(drywall butts non-comb. facing)
Min. Enclosure Height
NG = 62-3/4" (1594mm)
LP = 74-3/4" (1899mm)
IDB1031
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
38-1/4"
972mm
42-3/4"
1086mm
7-1/4"
184mm
Optional "CoolSmart TV" or
"Power Heat Duct" Connection
22" *
559mm
Baseplate
The bottom of the face is
1/8" (4mm) above the
baseplate.
5-5/8"
143mm
25-7/8"
658mm
44-3/4"
1137mm
7-3/4"
197mm
39-1/4"
997mm
37"
940mm
* See "Clearances" and "Framing Dimensions" for details.
Top Vent Configuration
8" (203mm) Ø Vent
28-5/8"*
728mm*
Page | 10
864ST Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
Side Vent Configuration
8" (203mm) Diameter Vent
38-1/4"
972mm
27"
686mm
Top Vent Configuration
8" (203mm) Diameter Vent
Weight: 310 Lbs (140.7 kg)
1" 25mm
35-1/4"
895mm
37"
940mm
38-1/4"
972mm
39-1/8"
994mm
33-7/8"
860mm
41-1/2"
1054mm
4-3/8"
111mm
3-3/8"
86mm
Lifting Handle Tabs
These tabs may be
used in conjuction with
the lifting handles
(98500711) - make sure
to use the required
adapters (250-01038)
41" 1041mm
44" 1118mm
Left
a' gauche
Front
avant
Right
droit
Rear
arrie're
* The 26" (661mm) dimension is based upon 1/2" (13mm)
drywall around the perimeter of the fireplace on both sides. If
using thicker drywall (or other facing), you will need to adjust this
dimension.
44"
1118mm
Minimum 42"(1067mm)
Fireplace Enclosure Height
NOTE:
The shaded framing must be
installed after placing the fireplace
in position.
The framing above the fireplace
interferes with the top of the fireplace.
If using the side vent configuration, do
not install the framing to the left side
(shown in light gray).
38-1/2"
978mm
26" *
661mm
Back
Front
Right
Left
Page | 11
3615HO Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
40-3/4" *
1036mm *
17" *
432mm *
54"
1372mm
37-3/8"
924mm
1"
25mm
* Includes the requisite clearance to framing
(1/8" 4mm to rear , 5/8" 16mm to the sides)
10-3/8"
264mm
15-3/4"
401mm
11-1/4"
286mm
947mm
37-1/4"
210 lbs.
96 Kg.
9-3/8"
239mm
34-3/4"
883mm
40-3/4"
1036mm
17" 432mm Flush Install
54"
1372mm
54"
1372mm
a
The fireplace enclosure must be a minimum 54”
1372mm tall (do not build into the fireplace
a
Page | 12
4415HO Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
48-3/4" *
1239mm *
1150mm
45-1/4"
255 lbs.
115 Kg.
17" *
432mm *
37-3/8"
924mm
1"
25mm
* Includes the requisite clearance to framing
(1/8" 4mm to rear, 5/8" 16mm to the sides)
10-3/8"
264mm
15-3/4"
401mm
11-1/4"
286mm
60"
1524mm
9-3/8"
239mm
34-3/4"
883mm
The fireplace enclosure must be a minimum
60” tall (do not build into the
fireplace
a
48-3/4"
1239mm
60"
1524mm
a
60"
1524mm
17"
432mm
Page | 13
4415 HO ST Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
* Includes the requisite clearance to framing
(5/8" 16mm to the sides)
16-1/4"
413mm
64"
1626mm
275 lbs.
125 Kg.
1150mm
45-1/4"
37-3/8"
924mm
1"
25mm
10-3/8"
264mm
15-3/4"
401mm
11-1/4"
286mm
52-1/4" *
1328mm *
34-3/4"
883mm
8-1/8"
207mm
52-1/4"
1328mm
Minimum 64"(1626mm) Fireplace
Enclosure Height
64"
1626mm
16-1/4" (413mm)
Page | 14
6015 HO Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
37-3/8"
924mm
1"
25mm
* Includes the requisite clearance to framing (1/8"
4mm to rear, 5/8" 16mm to the sides)
1556mm
61-1/4"
350 lbs.
156 Kg.
17" *
432mm *
10-3/8"
264mm
15-3/4"
401mm
11-1/4"
286mm
64-3/4" *
1645mm *
All Other
Installations:
66"
1677mm
LP Min. V ent
Installations:
72"
1829mm
72"
1829mm
64-3/4"
1645mm
72"
LP
LP
NG
NG
1829mm
17"
432mm
66"
1677mm
66"
1677mm
9-3/8"
239mm
34-3/4"
883mm
Page | 15
4237 Clean Face
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
37-1/4"
947mm
29-1/4"*
743mm*
17-1/4"
439mm
43-3/4"
1112mm
59-1/4"*
1505mm*
53-3/4"
1366m
m
1"
25mm
39"
991mm
51-1/8"
1299mm
a
b
c
11-3/8"
289mm
WEIGHT:
555 lbs.
252 Kg
10-3/4"
274mm
d
e
15-5/8"
397mm
* Includes 5/8" (16mm) Standoffs
Standard 28-3/4" (731mm)
Flush 29-1/4" (743mm)
54"
(1372mm)
59-1/2" (1512mm)
Minimum
Enclosure
Height
Minimum Enclosure Height
Minimum Vent
Configurations or Any System Height Under 10’
-- Minimum enclosure height is 89” (2261mm)
Minimum Enclosure Height –Vent Configurations
with System Height 10’ or Higher
-- Minimum enclosure height is 61” (1550mm)
-- Vent must pass vertically through the enclosure before an
elbow is placed on the vent.
Page | 16
ProBuilder™ 42 & 54 Linear
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
4-7/8"
(124mm)
15-7/8" *
(404mm) *
* Includes the required 1/2" clearance
to each side and rear of the fire
p
lace
.
20-1/2"
(521mm)
1-1/2"
38mm
3-3/4"
(96mm)
42 PB Linear 47-1/8" (1 197mm)*
54 PB Linear 59-1/8" (1502mm)*
S
c
r
e
e
n
F
r
a
m
e
W
i
d
t
h
4
2
P
B
4
5
-
3
/
4
"
(
1
1
6
3
m
m
)
5
4
P
B
5
7
-
3
/
4
"
(
1
4
6
7
m
m
)
42 PB = 165 lbs. 75 Kg.
54 PB = 210 lbs. 95 Kg.
Height
Screen
Frame
9-3/4"
(248mm)
31"
34-1/2"
(788mm)
(877mm)
34-1/2"
(877mm)
42 PB Linear
45-1/4" (1150mm)
15-7/8"
(404mm)
42 PB Linear 47-1/8" (1197mm)
54 PB Linear 59-1/8" (1502mm)
54 PB Linear
54-1/2" (1385mm)
Min. Enclosure
Height
Depth
3”
Header
Max.
(77mm)
IDB1100
Page | 17
ProBuilder™ 72 Linear
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
makin
g
installation decisions.
4-7/8"
(124mm)
77-1/8" *
(1959mm) *
275 lbs.
125 Kg.
15-7/8" *
(404mm) *
43"
(1092mm)
20-1/2"
(521mm)
7
5
-
3
/
4
"
(
1
9
2
4
m
m
)
1-1/2"
(38mm)
3-3/4"
(96mm)
* Includes the required 1/2" clearance to
each side and rear of the fireplace.
77-1/8"
(1959mm)
43"
(1092mm)
a
68"
(1727mm)
15-7/8"
(404mm)
Max. 3"
(77mm)
31"
788mm
9-3/4"
248mm
Page | 18
ProBuilder™ 24 Clean Face
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
1
5
-
1
/
4
"
(
3
8
8
m
m
)
*
24-5/8" (626mm)
2
4
"
(
6
1
0
m
m
)
S
c
r
e
e
n
F
r
a
m
e
W
i
d
t
h
Screen
Frame
Height
32-7/8”
(835mm)
1-5/8"
(42mm)
1” (26mm)
1/16” (1.6mm)
Bottom of optional
lower trim to base
of fireplace
(Ships STD)
145 lbs.
66 Kg.
24-5/8"*
(626mm)*
*Dimensions Includes the standoff
s
12
-
3/8"
(31
5mm
)*
5-7/8"
9-1/2"
(150mm)
*
(242mm)
35"
(889mm)
37-1/4"
41"
(947mm)
(1042mm
)
25-1/8"
(639mm)
41-1/4"
(1048mm)
15-1/2"
(394mm)
53" (1347mm)
Min.
Enclosure
Height
Depth
3”
Header
Max.
(77mm)
Page | 19
ProBuilder™ 36 Clean Face
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
making installation decisions.
1-5/8"
(42mm)
S
c
r
e
e
n
F
r
am
e
W
i
d
t
h
3
6"
(
91
5m
m
)
32-7/8"
(836mm)
3"
(77mm)
15-1/4"*
(388mm)*
36-5/8"*
(931mm)*
24-1/2"*
(623mm)*
Height
Screen
Frame
1 (26mm)
1/16” (1.6mm)
Bottom of optional
lower trim to base
of fireplace
(Optional Accessor
y
170 lbs. 77 Kg.
*Dimensions Includes the standoffs
18
-
1/
4"
(
4
6
4mm
)*
5-3/4"
9-1/2"
(147mm)
*
(242mm)
9-3/8"
(239mm)
35"
(889mm)
37-3/8"
41"
(950mm)
(1042mm
)
41"
(1042mm)
6
1-7/8"
(1572mm)
15-3/4"
(401mm)
37-1/8"
(943mm)
Min.
Enclosure
Height
Depth
3”
Header
Max.
(77mm)
Page | 20
ProBuilder™ 42 Clean Face
Framing Guide
12521 Harbour Reach Drive
Mukilteo, WA 98275-5458
Scan for
Installation Manual
This document is for reference
purposes only. Consult the
installation manual BEFORE
makin
g
installation decisions.
1-5/8"
42mm
37-7/8"
(963mm)
3"
(77mm)
17"*
(432mm)*
42-1/2"*
(1080mm)*
240 lbs. 109 Kg.
28-1/4"*
(718mm)*
1” (26mm)
1/16” (1.6mm)
Bottom of optional
lower trim to base
of fireplace
(Optional Accessor
y
S
c
r
e
e
n
F
r
a
m
e
W
i
d
t
h
4
2
"
(
1
0
6
7
m
m
)
Height
Screen
Frame
10-3/4"
(274mm)
40"
(1016mm)
42-3/8"
46"
(1077mm)
(1169mm
)
*Dimensions Includes the standoffs
21
-
1/4"
(
5
40
mm
)*
6-1/8"
10-5/8"
(156mm)
*
(270mm)
46-1/4"
(1175mm)
17-1/4"
(439mm)
43"
(1093mm)
6
8"
(1728mm)
Min.
Enclosure
Height
Depth
3”
Header
Max.
(77mm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI