  • Hello! I am an AI chatbot trained to assist you with the Techmaster T9530 Programming And Operating Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TechMaster
Lock system for safes
PROGRAMMING AND OPERATING
INSTRUCTIONS
IU_TechMaster_02_eng Page 3 of 32
Information about TechMaster ................................................................................................ 4
1. Master Menu ........................................................................................................................... 6
1.1. Set Time and Date ..................................................................................................... 6
1.2. Time Lock .................................................................................................................... 7
1.2.1. Time Lock - Add ...................................................................................................... 7
1.2.2. Time Lock - Verify or Delete ................................................................................. 8
1.2.3. Special Events - Add ............................................................................................... 8
1.2.4. Special Events – Verify or Delete ......................................................................... 9
1.2.5. Opening Periods - Add ......................................................................................... 10
1.2.6. Opening Periods – Verify or Delete .................................................................... 10
1.3. PC Link ....................................................................................................................... 11
1.4 Manager Management .............................................................................................. 11
1.5 Dynamic Codes .......................................................................................................... 12
2. Manager Menu ..................................................................................................................... 13
2.1. Users Management – Install/Delete/Enable/Disable users ................................ 13
2.2. Time Delay and Open Window .............................................................................. 13
2.3. Variable Time Delay ................................................................................................. 14
2.3.1. Variable Time Delay - Add ................................................................................... 14
2.3.2. Variable Time Delay - Verify or Delete .............................................................. 15
2.4. PC Link ....................................................................................................................... 15
3. OVR Manager Menu ............................................................................................................ 16
3.1. Users Management install/delete/disable user ................................................ 16
4. Change Code Menu ............................................................................................................. 17
4.1. Change Users and OVR Users Code ...................................................................... 17
4.2. Change Manager Code ............................................................................................ 17
4.3. Change OVR Manager Code ................................................................................... 18
4.4. Change Master Code ............................................................................................... 18
5. Time Menu ............................................................................................................................ 19
5.1 Opening Extension .................................................................................................... 19
5.2 Immediate Time Lock ............................................................................................... 20
6. Configuration Menu ............................................................................................................. 20
6.1. Install Locks .............................................................................................................. 21
6.2. Remove Locks ........................................................................................................... 21
6.3. LCD Contrast ............................................................................................................. 22
6.4. Language ................................................................................................................... 22
6.5. Membrane test .......................................................................................................... 22
6.6. System Info ............................................................................................................... 23
7. Opening the Locks ............................................................................................................... 23
7.1. Users (or OVR Users): Opening the lock without Time Delay .......................... 23
7.2. Users (or OVR Users): Opening the lock with Time Delay ................................ 23
7.3. Manager (or OVR Manager): Opening the lock
without Time Delay ............... 24
7.4. Manager (or OVR Manager): Opening the lock
with Time Delay ..................... 25
7.5. Opening the lock with Dynamic Codes (Dallas key option) ............................... 26
7.6. Opening the lock with Dynamic Codes (PIN option) .......................................... 27
7.7. Dual Mode: Opening
the lock without Time Delay ............................................. 27
7.8. Dual Mode: Opening the lock with Time Delay ................................................... 28
8. Shortcuts ............................................................................................................................... 29
9. Optional features ................................................................................................................. 29
Page 4 of 32 IU_TechMaster_02_eng
Information about TechMaster
Using your keypad
To power up TechMaster press any key.
To slide the functions of a menu use the slide/change button .
To exit from one function of a menu and go back to the main menu slide the functions
until the last one (“EXIT?”) and confirm with the confirm/enter button .
Automatic power savings: LCD will power-off after 30 seconds of non-operation.
TechMaster opening and administration codes
Every user (Manager, Standard user or Override) can be a numerical code or a
numerical code + Dallas key.
Master code can be only a numerical code.
Default TechMaster codes
Default code for TechMaster are:
Master 1 2 3 4 5 6 7 8
Manager 1 2 3 4 5 6
OVR Manager 6 5 4 3 2 1
User 2 0 2 0 2 0 2 0 2
User 3 0 3 0 3 0 3 0 3
.......... ............
User XY X Y X Y X Y X Y
Configuration Code 5 0 5 0 5 0
Factory code has to be changed, as soon as the system is initiated by the
final user.
Slide/Change
Confirm/Enter
IU_TechMaster_02_eng Page 5 of 32
Penalty
Four consecutive invalid codes initiates four minutes delay period. During this period
LCD will display the message “Penalty” when any operation will be performed.
Programming TechMaster
All the following programming instructions of TechMaster must be intended for only
one lock (this also includes Master and Manager codes). If your TechMaster has
more than one lock you must repeat the instructions for each installed lock.
Multiple Locks
TechMaster can manage up to five locks.
Time Delay
Can be set on each lock.
Delay Period: 0 – 99 minutes; Open Period: 1 – 19 minutes.
Five Time Delays can run at once.
Dallas keys
Can be set on each lock, requires code and key. Available for all Manager and Users
(not available for the Master).
TechMaster only works with Dallas keys coded by Tecnosicurezza.
Low Battery Warning
Long audio and visual signals during opening indicate low battery.
Emergency battery
If your TechMaster is powered by the mains or an internal battery box it is possible to
connect an emergency battery to the keypad in case of sudden blackout: connect a
new 9V ALKALINE battery to the battery connector located at the bottom of the
keypad.
Silent Alarm Signal
Can be set on each lock.
Remote Disable
Can be set on each lock.
Page 6 of 32 IU_TechMaster_02_eng
Audit
Each Lock will record last 900 operations with time & date, user and function.
Override Reopening
TechMaster can be set to have Override Reopening option (from 0 to 59 minutes). If
this option is set, it will be possible to reopen the lock overriding Time Delay during
the set value of time. This function is available only after a standard opening
procedure of the lock (after opening with time delay).
Important notes
Simple/trivial codes, which could be easily guessed (1,2,3,4,5,6) have to be
prevented.
Never remove lock cover, this voids the warranty.
1. Master Menu
Power up TechMaster.
Press . LCD will display the message:
MASTER MENU
X X X X X X X X
Enter Master code (default code 1-2-3-4-5-6-7-8).
SET
TIME AND DATE
08:00 FRI
27/01/2006
hh:mm _ _ _
DD / MM / YYYY
IU_TechMaster_02_eng Page 7 of 32
TIME LOCK
STANDARD WEEK 1
ADD
! hh:mm DAY
" hh:mm
! hh:mm DAY
" hh:mm
END OF LIST
EXIT AND SAVE? !
Page 8 of 32 IU_TechMaster_02_eng
ADD
STANDARD WEEK 1
VERIFY OR
DELETE
! hh:mm DAY
" hh:mm
DELETE?
!
END OF LIST
Time Lock Standard week is an Opening Time Period: the safe door can be opened if you
enter a valid code (for ex. Opening Period from 08:00 to 14:00: the door can be opened from
08:00 to 14:00, but can’t be opened at 16:00).
You can enter four different Time Periods for each day (for ex. MON from 07:00 to 10:00;
from 12:00 to 13:00; from 15:00 to 16:00; from 18:00 to 19:00).
Time Periods will be saved just after confirmation pressing . It is recommended to set
the values with safe door open.
All the Users will be automatically added to their related Time Lock table.
IU_TechMaster_02_eng Page 9 of 32
STANDARD WEEK 1
SPECIAL EVENTS
ADD
" DD/MM/YY hh:mm
! DD/MM/YY hh:mm
The first one is the closing time and date and the second one is the opening time and date.
Enter Closing and Opening time and date, then press to confirm.
If a value for Year is set, this Special Event will cease after that date.
If a value for Year is not set, this Special Event will repeat every year.
Repeat this procedure for every Special Event.
Special Events are Closing Periods: the safe’s door can’t be opened during these periods.
Up to 30 Special Events are available for a maximum of nine (9) days each.
STANDARD WEEK 1
SPECIAL EVENTS
ADD
VERIFY OR
DELETE
" DD/MM/YY hh:mm
! DD/MM/YY hh:mm
Page 10 of 32 IU_TechMaster_02_eng
DELETE?
!
END OF LIST
STANDARD WEEK 1
OPENING PERIODS
ADD
! DD/MM/YY hh:mm
" DD/MM/YY hh:mm
The first one is the opening time and date and the second one is the closing time and date.
Enter Opening and Closing time and date, then press to confirm.
If a value for Year is set, this Opening Period will cease after that date.
If a value for Year is not set, this Opening Period will repeat every year.
To cancel entered values, press .
Repeat this procedure for every Opening Period.
During Opening Periods it will be possible to open the safe’s door even if Time Lock is active.
Up to 30 Opening Periods are available for a maximum of nine (9) days each.
IU_TechMaster_02_eng Page 11 of 32
STANDARD WEEK 1
OPENING PERIODS
ADD
VERIFY OR
DELETE
! DD/MM/YY hh:mm
" DD/MM/YY hh:mm
DELETE?
!
END OF LIST
Use this function to start the communication between TechMaster and PC (audit, settings).
PC LINK
PC LINK
ACTIVE . . . . .
Depending on lock configuration this menu could not be available
Use this function to add, disable or delete Manager, OVR Manager and Remote Manager.
Page 12 of 32 IU_TechMaster_02_eng
MANAGERS
MANAGEMENT
1: MANAGER !
2: OVR MANAGER
!
01 ! T1
DISABLE?
01 ! T1
DELETE?
OPERATION
DONE
Depending on lock configuration this menu could not be available
Use this function to enable or disable the use of Dynamic Codes on the lock.
DYNAMIC
CODES
STATUS:
DISABLED/ENABLED
STATUS:
ENABLE?/ DISABLE?
OPERATION
DONE
STATUS:
REMOVE FROM ALL
OPERATION
DONE
If the use of Dynamic Codes has been removed and you want to activate it again, be sure
Dynamic Code option is enabled on the lock and use the Red Dallas and the key activation
code generated by the software to activate the function.
IU_TechMaster_02_eng Page 13 of 32
2. Manager Menu
Power up TechMaster.
Press and then press . LCD will display the message:
MANAGER MENU
X X X X X X
Enter Manager code (default code 1-2-3-4-5-6).
2.1. Users Management – Install/Delete/Enable/Disable users
Use this function to install, delete, enable or disable or disable Users on the lock.
USERS
MANAGEMENT
01 02 03 04
! ! ! !
01 ! T1
DISABLE?
xx ! T1
DISABLE?
xx
User ID
!
User installed
x
User disabled
User with 6 digits code
T1
User following time lock table number 1
User following variable time delay
User with Dallas key
Use this function to set, modify or verify Time Delay and Open Window values.
T. DELAY AND
O. WINDOW
Page 14 of 32 IU_TechMaster_02_eng
T. DELAY 00
O. WINDOW 01
T. DELAY mm
O. WINDOW mm
VALUES
UPDATED
Accepted values are: 00÷99min for Time Delay and 01÷19min for Open Window.
To set a lower Time Delay value than the currently set on the lock, the lock must be opened.
If the lock is closed it won’t accept the new entered values. Open the lock and then set new
Time Delay values.
Depending on lock configuration this menu could not be available
VARIABLE
TIME DELAY
ADD
END OF LIST
EXIT AND SAVE? !
IU_TechMaster_02_eng Page 15 of 32
To add Variable Time Delay values, the lock must be opened. If the lock is closed it will be
not possible to access the function. Open the lock and then set Variable Time Delay values.
Variable Time Delay always have to be increased or decreased in steps of 10 minutes from
the value of Time Delay (2.2.). If not, TechMaster will automatically adjust values to the next
available ones.
ADD
VERIFY OR
DELETE
08:00 SUN
10:00 : 01
DELETE?
!
END OF LIST
Use this function to start the communication between TechMaster and PC (audit, settings).
PC LINK
PC LINK
ACTIVE . . . . .
Page 16 of 32 IU_TechMaster_02_eng
3. OVR Manager Menu
Depending on lock configuration this menu could not be available
Power up TechMaster.
Press and then press two times. LCD will display the
message:
OVR MANAGER MENU
X X X X X X
Enter OVR Manager code (default code 6-5-4-3-2-1).
Depending on lock configuration you could find this menu inside Master menu or
inside Manager menu
Use this function to install, delete, enable or disable or disable OVR Users on the lock.
USERS
MANAGEMENT
50 51 52 53
! ! ! !
52 ! T1
DISABLE?
xx ! T1
DISABLE?
xx
User ID
!
User installed
x
User disabled
User with 6 digits code
IU_TechMaster_02_eng Page 17 of 32
T1
User following time lock table number 1
User following variable time delay
User with Dallas key
4. Change Code Menu
Personal data (like birthday) or other data which could be easily concluded with
some knowledge about the end user have to be prevented. After changing the code,
the lock has to be checked several times with open door.
Power up TechMaster.
Press and then press three times. LCD will display the
message:
CHANGE
CODE
Use this function to change Users and OVR Users code. Always perform this operation with
the door opened.
CHANGE USER
CODE
OLD CODE
X X X X X X X X
NEW CODE
X X X X X X
CONFIRM CODE
X X X X X X
Use this function to change Manager code. Always perform this operation with the door
opened.
CHANGE USER
CODE
CHANGE MANAGER
CODE
Page 18 of 32 IU_TechMaster_02_eng
OLD CODE
X X X X X X
NEW CODE
X X X X X X
CONFIRM CODE
X X X X X X
Use this function to change OVR Manager code. Always perform this operation with the door
open.
CHANGE USER
CODE
CHANGE OVR
MANAGER CODE
OLD CODE
X X X X X X
NEW CODE
X X X X X X
CONFIRM CODE
X X X X X X
Use this function to change Master code. Always perform this operation with the door open.
CHANGE USER
CODE
CHANGE MASTER
CODE
OLD CODE
X X X X X X X X
NEW CODE
IU_TechMaster_02_eng Page 19 of 32
X X X X X X X X
CONFIRM CODE
X X X X X X X X
5. Time Menu
Power up TechMaster.
Press and then press four times. LCD will display the
message:
TIME
MENU
Use this function to delay the beginning of Time Lock up to 2 hours more than programmed
Time Lock.
USER CODE
X X X X X X X X
MANAGER CODE
X X X X X X
OPENING
EXTENSION
OPENED UNTIL:
12/09 20:30
OPENED UNTIL:
DD/MM hh:mm
TIMELOCK NOT
PROGRAMMED
Page 20 of 32 IU_TechMaster_02_eng
USER CODE
X X X X X X X X
MANAGER CODE
X X X X X X
OPENING
EXTENSION
IMMEDIATE
TIME LOCK
CLOSED UNTIL:
14/09 08:00
CLOSED UNTIL:
DD/MM hh:mm
CLOSED UNTIL:
DD/MM hh:mm
6. Configuration Menu
Power up TechMaster.
Press and then press five times. LCD will display the
message:
CONFIGURATION
X X X X X X
Enter Configuration code (default code 5-0-5-0-5-0).
/