Harris NXAMP3801HDI, NEXIO AMP Generation 6, NXAMP3801HDX Hardware Installation And User's Manual

  • Hello! I am an AI chatbot trained to assist you with the Harris NXAMP3801HDI Hardware Installation And User's Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
NEXIO AMP
®
Generation 6
Hardware Installation and
User Guide
175-100423-00
Rev A
Copyright
©
2013 Harris Corporation. All rights reserved. No part of this documentation may be reproduced in any form, by any
method, for the purpose, without the written consent of Harris Corporation. Harris Corporation reserves the right to revise and
improve its products as it chooses. This publication is designed to assist in the use of the product, as it exists on the date of
publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This
publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers.
The Harris logo and assured communications are trademarks of Harris Corporation. All other trademarks are the property of their
respective
holders.
For more information about Harris products, contact Harris at Regional Service below.
Regional Service Contact Information
Technical support is available 24 hours a day, 7 days a week. You can contact technical support by phone or at
US,CANADA, CENTRAL AMERICA AND LATIN AMERICA:
Call: +1 416 445 4032
Toll Free: +1 888 534 8246
ASIA PACIFIC:
Monday to Friday: 9 am-5p
mHKT
Call: +852 2776 90628
After-Hour Hotline: +1 888 534 8246
EUROPE AND AFRICA:
Support Line: +44 118 964 8100
MIDDLE EAST AND SOUTH ASIA (MESA):
Sunday to Thursday: 9 am-6 pm (Dubai/standard Gulf Time)
Call: +971 4 4338250
After-Hour Hotline: +44 118 964 8100
3
Table of Contents
Chapter 1 Introduction.......................................................................................................7
NXAMP3801HDX/HDI Configurations .....................................................................7
NXAMP3801HDX/HDI Software Options .................................................................8
Key Features ...........................................................................................................8
Specifications .......................................................................................................10
System ......................................................................................................10
Video ........................................................................................................11
Audio ........................................................................................................11
Video Compression Information ................................................................12
RAID Redundancy ......................................................................................13
Optional Operating System RAID 1 ............................................................13
Timecode Connection Options ...................................................................13
Remote GPI Control ...................................................................................14
Remote Serial Interface ..............................................................................14
Controls ....................................................................................................15
Physical .....................................................................................................15
Power Supply ............................................................................................15
Chapter 2 Chassis Components................................................................................17
NXAMP3801HDX/HDI Front Panels ....................................................................... 17
Front Panel - HDX Only ..............................................................................17
Front Panel - HDI Only ...............................................................................18
Front Panel Components ...........................................................................19
LED Indicators .....................................................................................19
LCD and Keypad .................................................................................19
Fiber Optical Drive Carrier Indicator .....................................................20
USB Ports ............................................................................................20
SYS ID Front Panel Indicator/Switch .....................................................21
Drive Configuration ...................................................................................21
RAID Configurations ...........................................................................21
NXAMP3801HDX/HDI Back Panel .........................................................................24
Back Panel Components ............................................................................26
SYS ID Back Panel Indicator/Switch ......................................................26
Power Supply Alarm Reset ..................................................................26
Power Supply ......................................................................................26
HD/SD SDI Video .................................................................................27
Table of Contents
4
175-100423-00
Reference Ports .................................................................................. 27
AES Audio .......................................................................................... 27
USB Ports ........................................................................................... 27
RS232 ................................................................................................ 28
Fibre Channel (HDX Only) ................................................................... 28
DVI 1/ DVI 2 ....................................................................................... 28
Ethernet ............................................................................................. 28
GPI Ports ............................................................................................ 28
COM Ports ......................................................................................... 29
Chapter 3 System Installation .................................................................................. 31
NXAMP3801HDX/HDI Rack Installation ................................................................ 31
Rack Location ........................................................................................... 31
Prepare for Setup ...................................................................................... 31
Choosing a Setup Location ................................................................. 32
Warnings and Precautions ......................................................................... 32
Rack Precautions ................................................................................ 32
General System Precautions ................................................................ 32
Rack Mounting Considerations ................................................................. 33
Ambient Operating Temperature ........................................................ 33
Airflow ............................................................................................... 33
Mechanical Loading ............................................................................ 33
Circuit loading .................................................................................... 33
Reliable Ground .................................................................................. 33
Rack Mounting ......................................................................................... 33
To Rack Mount NXAMP3801HDX/HDI ................................................ 34
To Remove NXAMP3801HDX/HDI from a rack .................................... 34
Connecting NXAMP3801HDX/HDI Redundant Power Supplies .................. 35
Prevent Damage and Malfunction ........................................................................ 35
Hardware .................................................................................................. 35
Anti-Virus Software ................................................................................... 35
Operating System Updates ........................................................................ 35
Automatic Updates ................................................................................... 36
Chapter 4 Connector Pinouts..................................................................................... 37
COM PORT Pinouts .............................................................................................. 37
RJ-12 to DB-9 ........................................................................................... 37
Weidmüller GPI Connectors ................................................................................. 37
Specifications ............................................................................................ 37
GPI In ........................................................................................................ 38
GPI Out ..................................................................................................... 39
How to Wire Your NEXIO Weidmüller Male Connectors ............................ 40
Chapter 5 Monitoring Your NXAMP3801HDX/HDI.................................. 41
Status Monitoring ................................................................................................ 41
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
5
175-100423-00
Remote Monitoring Using IPMI ..................................................................41
BIOS Setup ................................................................................................41
NEXIO Monitor .....................................................................................................44
To Open NEXIO Monitor ............................................................................44
Selecting Monitored Diagnostics ................................................................45
LCD Keypad Buttons ............................................................................................46
Chapter 6 System Drive Recovery ..........................................................................47
System Recovery ...................................................................................................47
Initial WIM Recovery Image ........................................................................47
Prepare the Drive for Capture ............................................................. 47
Format a Third-Party USB Stick ............................................................47
Capture the WIM Image .....................................................................48
Apply the WIM Recovery Image .................................................................50
Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive ..............53
Creating a New RAID 1 Boot Drive ....................................................................... 53
Rebuilding a RAID 1 Boot Drive ............................................................................57
Chapter 8 Maintenance....................................................................................................61
Installation Tools ..................................................................................................61
Important Safety Guidelines .................................................................................61
Chassis Cover .......................................................................................................61
Removal ....................................................................................................61
Replacement .............................................................................................62
Replacing the Onboard CR2032 Battery ...............................................................62
Hot Swap Power Supplies .....................................................................................63
Replacing a Power Supply Module .............................................................64
Hard Drive Removal or Replacement .....................................................................65
Removing a Hard Drive Carrier from the Chassis ........................................65
Installing a Hard Drive into a Drive Carrier ..................................................65
Replacing a RAID 1 Boot Drive ...................................................................66
Replacing Media Drive - HDI Only ..............................................................67
AMI BIOS Recovery ...............................................................................................67
Fan Replacement ..................................................................................................69
Chapter 9 Troubleshooting ..........................................................................................71
BIOS Error Beep Codes .........................................................................................71
Non-fatal errors .........................................................................................71
Fatal errors ................................................................................................ 71
Power Supply Module Failure ............................................................................... 72
System Cooling ....................................................................................................72
CMOS Battery ......................................................................................................72
Table of Contents
6
175-100423-00
7
1
Introduction
This hardware and user guide provides important information for owners of the NEXIO AMP Generation 6
video server, the latest edition of the advanced media platform from Harris Broadcasting. This guide includes
information for both the Integrated and Shared Storage Transmission Server, the NXAMP3801HDI and
NXAMP3801HDX, respectively.
The 3RU NEXIO AMP
®
Server has undergone a transformation under the hood as it incorporates new
hardware including new processors, motherboard, graphic card and much more. As with its predecessor, the
NEXIO AMP Generation 6 supports up to 8 channels of SD-only I/O or up to 4 channels of mixed HD and SD
media. It is a resolution-independent platform supporting concurrent streams of SD, 720P, 1080i and 1080p
NXAMP3801HDX/HDI Configurations
NEXIO AMP Generation 6 is available in a variety of configurations. The available configurations are shown in
Table 1-1. The Software License Card provided with your server shows which configuration you have
purchased. If you want to upgrade to a different configuration, contact Harris BCD Support for an additional
license.
Table 1-1 NEXIO AMP Models
Model SD-Only Configuration
HD/SD- Mixed
Configuration
NXAMP3801HDX1 2-channel
NXAMP3801HDI1
NXAMP3801HDX2 4-channel 2-channel
NXAMP3801HDI2
NXAMP3801HDX3 6-channel 3-channel
NXAMP3801HDI3
NXAMP3801HDX4 8-channel 4-channel
NXAMP3801HDI4
Refer to Regional Service Contact Information on page 2.
Chapter 1
Introduction
8
175-100423-00
NXAMP3801HDX/HDI Software Options
The following software options are available for your NXAMP3801HDX/HDI:
Software License Upgrades The software license upgrades enable additional HD or SD channels, and
optional Media Applications.
Table 1-2 lists the additional software applications that are available for NXAMP3801HDX/HDI:
Table 1-2 Optional
Software Applications
Application Description
Closed Caption Import Support for exporting from a clip and importing to a clip closed caption data via FTP.
DNxHD Support Support for the recording and play out of DnxHD encoded clips.
H.264 Codec Support Support for the play out of h.264 encoded clips.
NEXIO AMP ChannelView Software that provides multiviewer I/O monitoring, enabling up to four NEXIO AMP
inputs
and four NEXIO AMP outputs to be viewed in real time on a computer
monitor.
NEXIO ClipSync Play back two separate clips together at the same time frame accurately.
NEXIO Instrinsic Mirroring
1
Software that controls and monitors mirroring of volumes on the NEXIO SAN. A
license is only required for SANs using the NXS3100
2
series of storage arrays.
NEXIO PlayList
3
Event sequencing application that runs on NEXIO NXOS or NEXIO Remote for media
playback.
NEXIO PRX Encoder Generate a simultaneous low resolution proxy of content being ingested via
baseband.
NEXIO Remote Remotely administer and control NEXIO video servers from any 64-bit Windows 7 PC
on
the same LAN as your NEXIO server.
NEXIO Track Router Software for NEXIO Remote and NXOS that controls the routing of audio on ingest,
the
addition of external audio and closed captions to stored media, and audio routing
rules on playout for multilingual broadcasts.
1
Optional for HDX only
2
NXS3100
3
Is included on the HDI model
Key Features
Table 1-3 outlines some of the key features of NXAMP3801HDX/HDI:
Table 1-3 Key Features
Features
HDX HDI
3RU form factor
8X internal SATA-2 hot-swappable drives (standard); additional 8X internal
SATA-2 hot-swappable drives (available for purchase)
Automatic Aspect Ratio Conversion (ARC) using AFD (HD configured
servers only)
Dolby® Digital and Dolby E audio pass-through
Dual hot-swappable power supplies
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
9
175-100423-00
Dual port 8 Gbps Fibre Channel support
Easy integration with IP networks using Gigabit Ethernet for media
transfers
EIA-608 <> EIA-708 and WST <> OP-47 closed caption transcoding using
software based real time processing (HD configured servers only)
HD scales to 500+ channels with NEXIO Farad High-Performance Storage,
and 210+ channels with NEXIO NXS3100 SBOD Storage Arrays
Includes FTP Server to move media from NEXIO to NEXIO or between
NEXIO and general purpose storage using the following file formats:
GFX
MOV
MPEG2 transport and program streams
MPEG4
MXF OP-1A
MXF OP-ATOM from P2 devices
Native LXF
WAV
Integrated up/down/cross conversion support using software based real
time processing (HD configured servers only)
Multitier user account access, prevents unauthorized operators from
altering video/audio procamps or deleting media
Off-speed play
Read, generate, and write continuous and discontinuous VITC
Record and playback HD:
MPEG-2 MP@HL l-frame 4:2:0 profile up to 100 Mbps, and 4:2:2
profile up to 150 Mbps
MPEG-2 MP@HL Long GOP 4:2:0 profile and 4:2:2 profile up to 80
Mbps
XDCAM HD at 35 Mbps (not available in 720p)
DVCPRO HD at 100 Mbps
XDCAM EX at 35 Mbps
XDCAM HD422 at 50 Mbps
H.264 playback only (optional)
DNxHD (optional)
AVC - Intra (playback optional)
Record and playback SD:
MPEG-2 l-frame and MPEG-2 Long GOP 4:2:0 profile up to 15 Mbps,
and 4:2:2 profile up to 50 Mbps
IMX 30, IMX 40, and IMX 50
DVCPRO25 and DVCPRO50
DVCAM at 25 Mbps (625 only)
H.264 playback only (optional)
Runs NEXIO operating system (NXOS) software for ingest, playout, file
transfers, content management, and additional optional applications
SD scales to 1600+ channels with NEXIO Farad High-Performance
Storage, and 450+ channels with NEXIO NXS3100 SBOD Storage Arrays
Table 1-3 Key Features (Continued)
Features
HDX HDI
Chapter 1
Introduction
10
175-100423-00
Specifications
This section describes the hardware and software specifications for NXAMP3801HDX/HDI.
System
Table 1-4 describes the general specifications for NXAMP3801HDX/HDI:
Table 1-4 General Specifications
Specifications HDX HDI
32 GB RAM
Dual-head DVI monitor interface
Four 10/100/1000Base-T Ethernet adapters
Four USB 2.0 ports on back panel
PCI Express platform
Single boot drive with optional second drive for RAID1
Two redundant 8 Gb Fibre Channel ports
Two Six-Core Intel Xeon 64-bit processors
Two USB 2.0 ports on front panel
USB keyboard and mouse (included)
Windows 7 Ultimate (64-bit)
Single boot drive with an option for a second drive for RAID 1
Software-based codecs for coding and decoding SD and HD media
Supports HD-SDI (SMPTE-292M) and AES/EBU interfaces
Supports NEXIO Farad shared storage with hundreds of terabytes of
usable shared storage with RAID-601 storage protection
Supports redundant Ethernet, which automatically switches operation
from one Ethernet network to the other, if one Ethernet network fails
Supports SD (525i, 625i) and HD (1080i, 1080p, 720p) content on the
same chassis
Supports up to 8 SD channels, or up to 4 HD channels
Two Six-Core Intel Xeon
®
64-bit processors
Works with a wide range of 3
rd
party automation, archiving, and media
management applications
Table 1-3 Key Features (Continued)
Features
HDX HDI
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
11
175-100423-00
Video
Table 1-5 describes the NXAMP3801HDX/HDI video specifications:
All SD and HD Input/Output Configurations require that you have registered your software. To
register your software, see the Software License Card provided with your system.
Table 1-5 NXAMP3801HDX/HDI Video Specifications
Aspect Ratio Conversion Up/down/cross conversion support
EIA-608 <> 708 & WST <> OP-47 caption conversion
AFD aspect ratio conversion
Port based aspect ratio conversion
User-based aspect ratio conversion
Channels SD = SDI (SMPTE-259M)
HD = HD-SDI (SMPTE-292M)
HD Aspect Ratio 16:9
HD Resolution and Frame
Rates
720p @ 25fps
720p @ 29.97fps
720p @ 50fps
720p @ 59.94fps
1080i @ 25fps
1080i @ 29.97fps
1080P @ 25fps
1080p @ 29.97fps
1080PsF @ 25fps
1080PsF @ 29.97fps
SD Aspect Ratio 4:3
16:9
SD Resolution and Frame
Rates
525 @ 29.97fps
625 @ 25fps
Audio
Table 1-6 describes the NXAMP3801HDX/HDI audio specifications:
Table 1-6 Audio Specifications
Channels & Formats 4 AES/EBU pairs per input channel
4 AES/EBU pairs per output channel
8 pairs embedded per input channel
8 pairs embedded per output channel
Compressed Audio Dolby Digital (AC-3) and Dolby E pass-through
Chapter 1
Introduction
12
175-100423-00
Video Compression Information
Table 1-7 lists HD and SD Compressions and Bit Rates for NXAMP3801HDX/HDI:
Table 1-7. Compressions
and Bit Rates
HD Compressions Bit Rate Audio Notes
MPEG2 4:2:0 I-Frame 50,80,100 Any audio configuration All HD resolutions
MPEG2 4:2:0 Long GOP 18,25,35,50,60,70,80
MPEG2 4:2:2 I-Frame 50,70,80,100,120,150
MPEG2 4:2:2 Long GOP 25,35,50,70,80
DVCPRO HD 100 8 ch @ 16-bit 720p, 1080i and 1080psf
XDCAM HD 35 4 ch @ 16-bit 1080i, 1080psf only
XDCAM EX 720p, 1080i and 1080psf
XDCAM HD422 50 4 ch or 8 ch @ 24-bit
AVC-Intra encode 50,100 Any audio configuration 720p, 1080i and 1080psf only, 2
channel
maximum
AVC-Intra decode 720p, 1080i, and 1080psf only,
NXCP
required
MPEG4 (h.264) decode
only
1-40 720p, 1080i and 1080psf, license
required
DNxHD 60-220
720p, and 1080i, license required
SD Compressions Bit Rate AUDIO Notes
MPEG2 4:2:0 4-15 Any audio configuration up to
8c
h
Long GOP and I-frame include the
same ranges
MPEG2 4:2:2 10-50
IMX 30,40,50
4 ch @ 24-bit or 8 ch @ 16-bit
DVCPRO 25,50 4 ch @ 16-bit
DVCAM 25
MPEG4 (h.264) decode
only
1-40 Any audio configuration License required (same as HD license)
Inputs 4 pairs HD-BNC, unbalanced (AES/EBU)
75 termination
1V p-p nominal levels
Outputs 4 pairs HD-BNC, unbalanced (AES/EBU)
75 termination
1V p-p nominal levels
Processing & Storage 16, 20, or 24-bit, PCM, 48kHz
Table 1-6 Audio Specifications (Continued)
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
13
175-100423-00
RAID Redundancy
Table 1-8 lists both the Integrated and Shared Storage versions of the NXAMP3801HDX/HDI level of
redundancy to protect against the failure of one or more storage drives:
Table 1-8 RAID Redundancy Specifications
Redundancy Specifications HDX HDI
Controller RAIDsoft™ software RAID management system
RAID Protection Schemes
Per Volume
RAID 3 (single drive parity; single drive failure
protection)
RAID 6 (double distribution parity; 2 drive failure
protection)
ECC (multiple drive parity; dual drive failure
protection)
Intrinsic Mirroring
Protection Scheme
Choice of RAID 3 or ECC storage protection plus
fully mirrored storage area networks
1
NEXIO Farad RAID-601 RAID 6 (drive protection) + RAID 0 (striping by
NEXIO's RAIDsoft to add bandwidth) + Intrinsic
Mirroring
1
Requires 2 SANs with identical configuration and capacity
Optional Operating System RAID 1
Table 1-9 explains RAID 1
Table 1-9 RAID 1 with optional boot drive
RAID 1 Description
HDX HDI
RAID 1 (Mirroring) protects data from drive failure
by simultaneously writing the same data to two
hard drives. Since each drive is an exact duplicate
of the other, you can continue working if one fails.
when an optional second OS drive is installed.
Timecode Connection Options
The following is a list of the timecode connection options for NXAMP3801HDX/HDI:
RS-232
TCP/IP
Leitch clock interface
VITC reader, writer, and generator
Chapter 1
Introduction
14
175-100423-00
Remote GPI Control
Table 1-10 and Table 1-11 describes the GPI control specifications for the NXAMP3801HDX/HDI:
Table 1-10 GPI output Specifications for the NXAMP3801HDX/HDI
Item Symbol Rating Unit
OUT 8 outputs (16 pin connector)
Load voltage (AC peak/DC) VOFF 20 VAC
Continuous load current IO 450 mA
ON resistance .8 ohms (typical)
5pF
Information correct according to data obtained by OMRON.
WARNINGS:
1 Be sure to turn OFF the power when wiring the Relay, otherwise an electric shock may be
received.
2 Do not apply overvoltage or overcurrent to the I/O circuits of the SSR, otherwise the SSR may
malfunction
or burn.
Table 1-11 GPI input Specifications for the NXAMP3801HDX/HDI
Item Symbol Rating Unit
IN 8 inputs (16 pin connector)
Forward current-continuous IF 60 mA
Forward Current-Peak IF (pk) 1.0A A
Reverse Voltage VR 6.0 V
LED Power Dissipation @ TA=25
ºC PD 150 mW
Information correct according to data obtained by Fairchild
Remote Serial Interface
The following is a list of the remote serial interface specifications for NXAMP3801HDX/HDI:
RS-422 ports for control of up to eight channels; one port can be allocated for a VTR
RJ-12 connector
Harris ADC VDCP pinout. Refer to Chapter 4, Connector Pinouts on page 37.
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
15
175-100423-00
Controls
Table 1-12 describes the NXAMP3801HDX/HDI control specifications:
Table 1-12 Control Specifications
Input/Output
Ethernet, TCP/IP via socket or UDP
RS-422
GPI
Protocols
NEXIO Native Protocol
VDCP
Sony 9-Pin
Physical
Table 1-13 describes the NXAMP3801HDX/HDI size specifications:
Table 1-13 Size Specifications
Height 5.25 in. (13.4 cm); 3RU
Width 19 in. (48.3 cm)
Length 26 in. (71.4 cm) from the rack ears to the rear panel
Weight 47 lbs. (21.3 kg)
1
62 lbs. (28.12 kg)
2
1
HDX only
2
HDI only
Power Supply
Table 1-14 describes the system power specifications of the redundant power supplies:
Table 1-14 Redundant dual hot-swappable, dual load-sharing
Item Specification
Efficiency Level Certification 80 PLUS - Gold Level Certified
AC Input High Efficiency Power Supply
(1+1) 750W Redundant AC-DC
AC Input
700 W: 100-140 V, 50/60 Hz, 12 Amp
750 W:180-240V, 50/60 Hz, 6 Amp
DC Output (+12V) 62 Amp
DC Output (+5V) Standby 3 Amp
Chapter 1
Introduction
16
175-100423-00
17
2
Chassis Components
This chapter provides details on the front and back components of the NXAMP3801HDX and
NXAPMP3801HDI system.
NXAMP3801HDX/HDI Front Panels
A description of the front panel is shown in Table 2-1. The front panel of NXAMP3801HDX is shown in
Figure 2-1 and front panel of NXAMP3801HDI is shown in Figure 2-2 on page 18.
Front Panel - HDX Only
Figure 2-1 NXAMP3801HDX
Chapter 2
Chassis Components
18
175-100423-00
Front Panel - HDI Only
Figure 2-2 NXAMP3801HDI
Table 2-1 NXAMP3801HDX/HDI Front Panel
Item Number
Description For Additional Information
HDX
(
Figure 2-1)
HDI
(Figure 2-2)
1 1 LED Indicators used to monitor NEXIO AMP.
LED Indicators on page 19
2 2 LCD and Keypad work together to provide a
user
interface.
LCD and Keypad on
page 19
LCD Display Navigation
Sample
on page 46
3 3
4 4 Operating system (drive 0).
Drive Configuration on page 21
5 5 Optional drive, requires drive 0 for RAID 1.
6 6 USB Ports.
USB Ports on page 20
7 7 Alternate action illuminated pushbutton switch
used
to identify NXAMP3801HDX/HDI from
both the front and back panel. The blue
indicator can be turned on/off from either the
front or back panel.
SYS ID Front Panel Indicator/
Switch
on page 21
8 Optional Hot swappable media drives
configured RAID 3 or RAID 6.
Drive Configuration on page 21
NXAMP3801HDX/HDI
NEXIO AMP Generation 6 Hardware Installation and User Guide
19
175-100423-00
Front Panel Components
LED Indicators
The LED Indicators, Table 2-2, are used to monitor status and health of the frame. For more information on
monitoring NXAMP3801HDX/HDI, see Selecting Monitored Diagnostics on page 45.
Table 2-2 LED Front panel LED indicators
Front Panel LEDs
LED
Color
Description
TEMP Green Displays the current status of the CPU temperature.
Red Indicates temperature above critical threshold.
FAN Green Displays the current status of the fan.
Red Indicates fan stopped rotating or falls below programmed RPM limit.
PS Green Indicates the power supply is operating correctly.
Red Indicates power supply fault, drive problem or drift.
MEDIA Green Displays the current status of the LLM.
Red Indicates a critical problem due to drift or a drive problem.
LCD and Keypad
The LCD and keypad (Figure 2-3) work together to provide a user interface that enables you to power on,
power off, and reset the system. You can also view status and monitor the system using the arrow keys. (For
more information, see LCD Keypad Buttons on page 46).
Figure 2-3 LCD and Keypad
Power On/Reset Button:
The power on/reset button enables you to turn on NXAMP3801HDX/HDI, and reset the system.
Turn On press and hold the button for 5 seconds to power on the system.
System Reset when powered on; press and hold the button for 3 seconds to
reset the system.
Chapter 2
Chassis Components
20
175-100423-00
.
Power Off Button:
The power off button enables you to shut down the system as described below
Power Off press and hold the power off button for 5 seconds to shut down the
system.
Arrow Button:
The arrow buttons enable you to access information and system status. For more
information on using the arrow buttons, see LCD Keypad Buttons on page 46.
Fiber Optical Drive Carrier Indicator
Each SAS3/SATA drive carrier (Figure 2-4) has one fiber optical carrier indicator on the front of the carrier.
Figure 2-4 Carrier status indicator
Blue:
When flashing indicates drive activity.
When solid indicates possible drive fault
USB Ports
The NXAMP3801HDX/HDI has two Universal Serial ports on the front panel.
The following USB devices can be used as sources and destinations when moving content in and out of the
server:
NXUSBLTC
NXUSBTC (for time code power only)
USB CD-ROM/R/RW drives (source only)
USB DVD-ROM/RW/RAM drives (source only)
USB hard drives
USB thumb drives
NXAMP3801HDX/HDI supports USB 1.0, 1.1, and 2.0.
/