Caple CE1101, CE1121 User manual

  • Hello! I am an AI chatbot trained to assist you with the Caple CE1101 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Instruction manual for ceiling hoods
Model code: CE1500 Model code: CE1100
Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk
Model code: CE1105 Model code: CE901
Model code: CE1101
2
CONTENTS
Warnings
Uses
Installation
Working
Maintenance
3
GB
WARNINGS
The appliance is not intended for use by
young children or inrm persons without
supervision. Young children should be su-
pervised to ensure they do not play with
the appliance.
The air sucked can’t be conveyed throu-
gh or into a duct used to let out fumes
from appliances fed by energy other than
electric power (eg. centralized heating, ra-
diators, water-heaters, etc.).
To evacuate the air outlet, please comply
with the pertaining rules given by compe-
tent authorities.
Provide the room with an adequate aeration
when a cooker hood and appliances fed by
energy other than electric power (gas-, oil-,
or coal- stoves, etc.) are used simultaneously.
The cooker hood, when evacuating the sucked
air, could generate a negative pressure in the
room- which can’t exceed the limit of 0.04
mbar, in order to avoid the suck of exhausts
deriving from the heat-source. Therefore the
room should be provided with air-intakes to
allow a costant ow of fresh air.
If the rating lable in the cooker-hood shows
the symbol , the appliance is built in class
II° and it does not need any earth connec-
tion.
If the rating lable in the cooker-hood does
not show the symbol , the appliance is
built in class and it needs the earth con-
nection.
When performing the electrical connections
on the appliance, please make sure that the
current-tap is provided with earth connection
and that voltage values correspond to those
indicated on the label placed inside the ap-
pliance itself.
Before carrying out any cleaning or maintai-
ning operations, the appliance needs to be
removed from the electric grid.
If the appliance is not provided with a non-
separable exible cable and plug, or with
4
another device ensuring omnipolar discon-
nections from the grid, with an opening di-
stance between the contacts of at least 3 mm,
then such disconnecting devices must be
supplied within the xed installation.
If the appliance is endowed with a supply cord
and a plug, the appliance has to be put in a
place where the plug can be reached easily.
The use of materials which can burst into
ames should be avoided in close proxi-
mity of the appliance. When frying, please
pay particular attention to re risk due to
oil grease. Being highly inammable, fried
oil is especially dangerous. Do not use un-
covered electric grills. In order to avoid
possible re risk, all instructions for grea-
se-lter cleaning and for removing even-
tual grease deposits should be strictly fol-
lowed.
USES
CE1500 - CE1101 - CE1105 - CE901 with
external motors manufactured by the same
producer.
PANELS OPENING
In CE1500, CE1101, CE901 models it is pos-
sible to open the steel panels, which cover
the grease lters, by slightly pulling on a side
of the panel itself, as shown in Fig. 3.
In CE1105 model, to open the panels you
need to push the appropriate hooks placed
on the sides of the panel , as shown in Fig. 11
and then rotating the panel downwards.
To achieve the complete opening of panels,
you need to release the safety chains, by
using the appropriate spring catches.
5
For proper working, it is recommended to in-
stall the appliance at a distance of 2000
- 2100 mm from the oor.
Before starting the appliance installation,
please check that all components are not da-
maged,
in such a case contact your retailer and do not
carry out installation.
Furthermore, please read carefully all of the
following installation instructions.
- Use an exhausting pipe whose maximum
length does not exceed 5 meters.
- Limit the no. of elbows in the piping, since
each elbow reduces the air capacity
of 1 linear meter. (Ex.: if you use no. 2 x 90 °
elbows, the length of piping must not exceed
3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for
the whole length.
- Use piping approved by standards in force.
INSTALLATION
CE1500 - CE1101 - CE1105 - CE901
Fit a false ceiling with an opening of the fol-
lowing sizes:
CE1500: 1465x965 mm with a minimum di-
stance of 270 mm between the ceiling and
the false ceiling;
CE1101: 1065x665 mm with a minimum di-
stance of 270 mm between the ceiling and
the false ceiling.
CE1105: 1050x645 mm with a minimum di-
stance of 250 mm between the ceiling and
the false ceiling;
CE901: 865x405 mm with a minimum di-
stance of 270 mm between the ceiling and
the false ceiling;
It is possible to select the side of the hood
where the air suctioned can be discharged.
After having chosen the most suitable posi-
tion, prepare the ducting: an air outlet con-
nection piece, with a diameter of 150 mm to
be installed in the side selected, is provided
with the appliance.
Leave any unused exhaust outlets closed.
Draw the outline of the hole to house the cei-
ling-mounted hood on the solid ceiling (Fig.
1), according to the model chosen; make 4
holes in the ceiling according to the dimen-
sions shown in (Fig. 2); place the metric plugs
provided in the holes.
Open the stainless steel panels, following
the instructions mentioned in the USES sec-
tion, and remove the grease lters in order
to avoid damaging them in any way and too
allow installation (Fig. 3); screw the threa-
ded bars provided into the plugs (Fig.4); the
threaded bars are 250 mm long and serve to
install the ceiling-mounted hood at a distan-
ce from the solid ceiling of between 270 mm
and 370 mm (Fig. 5); If the hood is installed
with lateral air outlet, t a false ceiling with
an opening that has a minimum gap of 210
mm between the ceiling and the false ceiling
(Fig. 12); in case of a larger gap between the
hood and the ceiling, you need to use longer
threaded bars.
6
The “light” switch can turn the lights on and
off. CE1500 CE1101:
after the first touch of
the light switch the lamps turn on at the
maximum power. Keeping the switch
pressed the inten-sity of the light decreases
and then increases continuously. Leaving the
switch the bright-ness remains set up.
Touching again the light switch it is possible
to turn the lamps off.
- To set the timer up press the
button:
The LED on the right side will start to ash
(every 5 seconds), the hood will work for 10
minutes at the selected speed and then it
lights automatically o. If the client increases
or reduces the speed while the timer is on,
this is automatically stopped.
Make the electrical connections and connect
the air outlet pipe; place the ceiling-mounted
hood into the niche, by inserting the threaded
bars into the holes (Fig.6); the outer edge of
the hood needs to be perfectly ush with the
false ceiling. Insert the plates and nuts pro-
vided into the threaded bars, making sure to
tighten them securely (Fig. 7); ret the grease
lters and lter cover panels.
Connect the internal motor or the external
motor’s cable to the terminal board found in-
side the plastic box of the wiring . Make
sure to respect the cables colours when
performing the electrical connection (fig.16).
Standard conguration
If two cookerhoods-radiocontrol system are
installed in the same room or in the immediate
vicinity, each system may aect the operation
of the other, due to the fact that they have the
same code. Therefore it will be necessary to
change the code of one of the radio controls.
Warning:
The battery should be replaced every ye-
arto guarantee the optimal range of the
transmitter. To replace the exhausted bat-
tery, take the plastic lid o, remove the
battery and replace it with a new one, ob-
serving the correct battery polarities. Used
batteries should be discarded in special
collection bins.
Generating a new transmission code
The radiocontrol is supplied by the manu-
facturer with default codes stored. If you
want to create a new set of codes, proceed
as follows:press and hold the UP, STOP and
DOWN buttons simultaneously for 2 secon-
ds. Afterthe LEDS light up, press the UP and
DOWN button swithin 5 seconds. The LEDS
will ash 3 times to indicate that the process
is completed.
WARNING: This procedure deletes all pre-
viously stored codes.
6 - channel radio control for cooker hood re-
mote (g. 10).
Technical data:
Alkaline battery powered: 12v mod. 23A
Operating frequency: 433.92 Mhz
Combinations: 4096
Max. consumption: 25mA
Operating temperature: -20° : +55°C
- To light the cooker hood on or to
light it o press the button:
- To increase the speed up to the
fourth one press the button:
- To reduce the speed up to the
second one press the button:
- To go from a high speed back to
the rst one press twice the button:
- To give power to the lights or to
shut them down press the button:
HOW TO USE
MAINTENANCE
An accurate maintenance guarantees good
functioning and long-lasting performance.
A special care must be paid with grease l-
ters: to remove the grease lter please follow
the instructions given in the ‘USES’ section ,
according to the model chosen.
Remove the grease lter by pulling its han-
dle.
To reinsert the grease lter after the cleaning,
just perform the opposite operation.
Attention: after refastening the stainless steel
panel make sure that it is properly xed.
To clean the appliance itself tepid water and
neutral detergents are recommended, while
abrasive products must be avoided.
For steel appliances specialized detergen-
ts are recommended (please follow the in-
structions mentioned on the product itself to
obtain the desired results).
To replace the lamp, (CE1500 - CE1101)
remove the lamp (Fig. 9) and replace it with a
lamp of the same kind.
To replace the uorescent lamps (CE1105)
you need to disconnect the appliance from
the electrical network, then open the panel
following the instructions given in the ‘USES’
section.
Remove the perimeter screws shown in g.
13; pull the uorescent lamps support out
(g.14), and replace the old lamp with a new
one of the same kind.
Ret the panel and the screws previously re-
moved.
To replace led strip (CE901)
Using an appropriate tool, remove the LED
bar from its seat (refer to g. 15), discon-
nect it electronically using the appropriate
connector then substitute it with a LED bar
with same characteristics.
7
Learning the new transmission code
After changing the transmission code on
the radio control, the cooker hood electro-
nic control unit must be made to set the new
code as follows: press the main Power O
button on the cookerhood (g. 8) and then
restore power to the electronic control unit.
Within the next 15 seconds, press the Light
button. This will ensure the control unit is
synchronized with the new code.
TIMING
As a result of the new EU65 “Energy label” and
EU66 “ Ecodesign” regulations issued by the
European Commission, which came into force
as from January 1st, 2015 , our products have
been adapted to comply with these new re-
quirements.
All of the models complying with the energy
label requirements, are equipped with new
electronics including a timer device for suc-
tion speeds control, when the air capacity ex-
ceeds 650m³/h.
Internal motor models, with maximum air
capacity higher than 650m³/h, are equip-
ped with a timer device that automatically
switches the suction speed from 4th to 3rd
speed, after 5 minutes operation.
External motor models are equipped with re-
mote motors that , as for internal motor ver-
sions, include a timer device that switches
down the suction speed when it exceeds 650
mᵌ/h. (See External Motors Instructions )
Remote motors, whose air capacity exceeds
650m³/h at both 4th and 3rd speed , will
have the following by default timer control
functions:
The suction speed is automatically switched
from 4th to 2nd speed, after 6 minutes ope-
ration.
If the appliance is working at 3rd speed, it is
automatically switched to 2nd speed, after 7
minutes operation. Operation speeds can
also be changed during operation.
The energy consumption of the appliance in
stand – by mode is lower than 0.5W.
8
1
4
2 5
3
9
6
7
9
8
10
11
10
12
14
13
15
16
11
90095001101 - GM 04/15
Caple
Fourth Way
Avonmouth
Bristol
BS11 8DW
www.caple.co.uk
Serial number
/