S p e c i f i c a t i o n s
Accuracy is specified for a period of one year after calibration and at 64˚
to 82˚F (18˚ to 28˚C) with relative humidity to 80%.
DC Voltage
Overload protection: 250V rms. For 200 mV range and 600V DC or rms.
AC for other ranges.
DC Current
Overload protection: F 200 mA/250V fuse. (10A range unfused)
AC Voltage
Overload protection: 600V DC or rms. AC for all ranges.
Frequency range: 40Hz to 400Hz.
Response: Average responding, calibrated in rms. of a sine wave.
M a i n t e n a n c e
Periodic service
WARNING!
Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from
electrical shock and personal injury this meter provides to the
operator. Perform only those maintenance tasks that you are
qualified to do.
These guidelines will help you attain long and reliable service from
your meter:
1. Calibrate your meter annually to ensure it meets original
performance specifications.
2. Keep your meter dry. If it gets wet, wipe it dry immediately. Liquids
damage electronic circuits.
3. Whenever pra c t i cal, keep the meter away from dust and dirt, which
can cause premature wear.
4. Although your meter is built to withstand the rigors of daily use, it
can be damaged by severe impacts. Use reasonable caution when
using and storing the meter.
Cleaning and Decontamination
Periodically clean your meter’s case using a damp cloth. DO NOT use
abrasives, cleaning solvents or strong detergents, as they may damage
the finish or affect the reliability of the structural components.
Battery and Fuse Replacement
If “ “ appears on display, it indicates that the battery should be
replaced. Always use a fresh replacement battery of the specified size
and type. Immediately remove the old or weak battery from the meter
and dispose of it in accordance with your local disposal regulations. Old
or defective batteries can leak chemicals that corrode electronic circuits.
To replace battery and fuse (200mA/250V) remove the 2 screws in the
bottom of the case. Simply remove the old, and replace with a new one.
WARNING!
To avoid electric shock, be sure to turn off the meter’s power and
disconnect both test leads from any equipment before you remove
or install batteries.
UTL33-MAN P. 3
Maximum voltage between CAT II 600V
terminals and earth ground
Fuse protected F 200mA/ 250V
Power 9V battery, NEDA 1604 or 6F22
Display LCD, 1999 counts, updates 2-3/ sec
Measuring method Dual-slope integration A/D converter
Over range indication Only figure “1” on the display
Polarity indication “-” displayed for negative polarity
Operating environment 0˚ to 40˚C
Storage temperature -10˚ to 50˚C
Low battery indication “ “ appears on the display
Size 138 x 69 x 31 mm
Weight Approx. 170g
Range Resolution Accuracy
200 mV 100 µV ±0.5% of reading ±2 digits
2 V 1 mV
20 V 10 mV
200 V 100 mV
600 V 1 V ±0.8% of reading ±2 digits
Range Resolution Accuracy
200 µA 0.1 µA ±1% of reading ±2 digits
2 mA 1 µA
20 mA 10 µA
200 mA 100 µA ±1.5% of reading ±2 digits
10 A 10 mA ±3% of reading ±2 digits
Range Resolution Accuracy
200 V 100 mV ±1.2% of reading ±10 digits
600 V 1 V