JUNG PCT15EBG Operating instructions

Type
Operating instructions
KNX Flush box for Flat Panel PC
Ref.-no.: PCT 15 EBG
Mounting instructions
Flush box of Flat Panel PC
1. Safety instructions
Attention! Installation and mounting may only carried out by
qualified electrician.
Non-observance of the installation instructions may cause electrical
shock, fire or other hazards.
2. Function
The flush box enables the flush-mounted installation of the Flat Panel PC.
3. Equipment configuration
Oben /TOP
1
2
3
4
5
6
7
8
9
10
11
1 4 x fixing clamps for solid walls (not pre-assembled)
2 4 x clamps (for hollow wall mounting)
3 Cable duct for 10/100 Mbit fast Ethernet
4 Cable duct for USB connection
5 Cable duct for KNX Bus connection
6 Cable duct for power supply AC 230 V~
7 Connection for power supply
8 USB data interface (optional)
9 Rail for REG devices
10 Cat. 6 RJ 45 Modular Jack (optional)
L Bending radius (11) for LAN cable according to cable manufacturer
Stand: Okt-08
00240 991 00
KNX Flush box for Flat Panel PC
Ref.-no.: PCT 15 EBG
4. Assembling
4.1. Mounting in hollow wall
Dimension for cut-out:
Width: 400 mm
Height: 318 mm
Connect the flush box with the clamps (2).
Clamps for wall thickness of approx. 10 - 30 mm
L Fixing clamps for solid walls are not required.
Push the required cables through the provided gaskets
into the flush box
Close all unused cable ducts with gaskets
4.2. Mounting in solid walls
Connect the 4 fixing claws for solid walls (1) with the enclosed screws
to the flush box.
Push the required cables through the provided gaskets
into the flush box
Close all unused cable ducts with gaskets
Close all holes with duct tape
L Intruding cement or plaster can cause damage to the housing or
mechanical parts
5. Connection
Connection of power supply AC 230V~
L
N
PE
A
C 230V~
L
PE
N
1
2
Use mechanical switch or switch actuator (12) to connect or
disconnect the mains
L Once the system has been shut down, a reboot of the Flat Panel
PC takes place only after re-connection of mains.
6. Technical data
Power supply: AC 230 V ~
Dimension: ca. 316 x 399 x 68 (H x B x T)
2
KNX Flush box for Flat Panel PC
Ref.-no.: PCT 15 EBG
7. Optional equipment
USB data connection, Ref.-No.: 2130 USB REG
Cat. 6 RJ 45 Modular Jack
8. Acceptance of guarantee
We accept the guarantee in accordance with the corresponding
legal provisions.
Please return the unit postage paid to our central service
department giving a brief description of the fault:
ALBRECHT JUNG GMBH & CO. KG
Service-Center
Kupferstr. 17-19
D-44532 Lünen
Service-Line: 0 23 55 . 80 65 51
Telefax: 0 23 55 . 80 61 89
General equipment
Service-Line: 0 23 55 . 80 65 55
Telefax: 0 23 55 . 80 62 55
KNX equipment
Service-Line: 0 23 55 . 80 65 56
Telefax: 0 23 55 . 80 62 55
The
-sign is a free trade sign addressed exclusively to the
authorities and does not include any warranty of any properties.
3
  • Page 1 1
  • Page 2 2
  • Page 3 3

JUNG PCT15EBG Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI