Installation Instructions for Helical Pole Support
©
Copyright 2011 Hubbell Incorporated
NOTE: Hubbell has a policy of continuous product improvement. We reserve the right to change design and specications without notice.
! WARNING
Failure to monitor the condition of all parts and take 
corrective action as necessary may lead to failure during 
use resulting in personal injury or property damage.
Check all output string bolts along the drive train 
periodically to ensure they remain tight. Loose or damaged 
bolts may fail at, or below the anchor’s torque rating or 
contribute to damage elsewhere in the output string. Check 
all parts periodically for wear or damage and replace as 
necessary. Replacement bolts must be the same grade and 
length as the originals.
These instructions are intended to illustrate the use of the Helical Pole Support. Anchor installing tools covered
in this instruction sheet should be used by competent personnel familiar with and following good work and safety
practices. Should additional information and details be desired, or if specific situations arise which are not covered
adequately for the users purpose the specifics should be referred to Hubbell Power Systems (HPS). In some cases,
HPS may make specific recommendations concerning installation torque and installed depth limits for specific
applications.
NOTE: The Locking Dog Assembly has three positions. The inside
ring position allows the locking dogs to hold both the drive end
assembly and the anchor rod. The middle position releases the
anchor rod but holds the wrench drive end assembly. The outside
position releases the Drive-End Assembly
RECOMMENDED TIGHTENING TORQUES
BOLT DRY TORQUE (ft.-lb.)
1/2" - Gr. 5 75
5/8" - Gr. 2 95
1/2" - Set Screw 15 to 20
3. Before installing the Drive End Assembly in the
Locking Dog Assembly, open the dogs by pulling
outward and twisting in a counterclockwise direction
until the release rings rest on the outside stops.
1. Slide Kelly bar into the socket on the Kelly Bar
Adapter. Holes in the two opposite walls of the socket
allow the kelly bar shaft to be pinned in place with
the bent-arm pin provided. Coil locks are provided
and must be used to keep the bent arm pin from slip-
ping out. These pins should be checked periodically
and replaced with original equipment as necessary to
avoid failure.
2. When mounting the Locking Dog Assembly directly
in a Chance Kelly Bar Adapter (both having clear-
ance holes) use the 1/2-inch diameter grade 5 bolts,
or the 5/8-inch diameter grade 2 bolts, nuts, and
lockwashers provided with the Locking Dog Assembly
or those provided with the Kelly Bar Adapter. When
mounting the Locking Dog Assembly to a Chance
Kelly Bar Adapter (having tapped holes), the 1/2-
inch diameter grade 5, or the 5/8-inch diameter grade
2 bolts provided with the Kelly Bar Adapter must be
used. Those provided with the Locking Dog Assembly
will not work.
4. With the release rings
in the outside position,
insert the Drive End
Assembly into the
Locking Dog Assembly.
Rotate rings to the inside
position to capture drive
end in the Locking Dog
Assembly.
5. Assemble the lead section,
extension, and Helical
Pole Support together.
Place the anchor assembly
into the center of the hole.
6. Insert the Drive End
Assembly into the Helical
Pole Support.
. . . continued on next page . . .
®
CHANCE – CENTRALIA, MISSOURI 
Bulletin 04-1101
HUBBELL
®
Power Systems
! CAUTION
Dangerous stored energy can cause severe injury or death.
Relieve installation torque from output string before 
removing the wrench.
2
7. Begin driving the anchor assembly into the ground.
Maintain down pressure during installation to
ensure tool engagement.
10. Continue installing until Helical Pole Support
reaches the bottom of the hole. Remove the Drive
End Assembly and set the pole according standard
practices.
9. Torque can be monitored during installation.
8. If additional anchor length is required, stop
installing when the Helical Pole Support coupling is
at grade. Remove Helical Pole Support and add an
extension. Then bolt Helical Pole Support back to
the extension and continue driving. Repeat this step
until desired depth is reached..
These instructions do not claim to cover all details or variations in equipment, nor to provide for all  possible conditions to be 
met with concerning installation,operation,or maintenance of this equipment. If further information is desired or if particular 
problems are encountered which are not sufficiently covered in this guide, contact Hubbell Power Systems.
  • Page 1 1
  • Page 2 2

Hubbell 04-1101 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI